scholarly journals Biomechanics of cervical tooth region and noncarious cervical lesions of different morphology; three-dimensional finite element analysis

2016 ◽  
Vol 10 (03) ◽  
pp. 413-418 ◽  
Author(s):  
Selma Jakupović ◽  
Ivica Anić ◽  
Muhamed Ajanović ◽  
Samra Korać ◽  
Alma Konjhodžić ◽  
...  

ABSTRACT Objective: The present study aims to investigate the influence of presence and shape of cervical lesions on biomechanical behavior of mandibular first premolar, subjected to two types of occlusal loading using three-dimensional (3D) finite element method (FEM). Materials and Methods: 3D models of the mandibular premolar are created from a micro computed tomography X-ray image: model of sound mandibular premolar, model with the wedge-shaped cervical lesion (V lesion), and model with saucer-shaped cervical lesion (U lesion). By FEM, straining of the tooth tissues under functional and nonfunctional occlusal loading of 200 (N) is analyzed. For the analysis, the following software was used: CTAn program 1.10 and ANSYS Workbench (version 14.0). The results are presented in von Mises stress. Results: Values of calculated stress in all tooth structures are higher under nonfunctional occlusal loading, while the functional loading is resulted in homogeneous stress distribution. Nonfunctional load in the cervical area of sound tooth model as well as in the sub-superficial layer of the enamel resulted with a significant stress (over 50 [MPa]). The highest stress concentration on models with lesions is noticed on the apex of the V-shaped lesion, while stress in saucer U lesion is significantly lower and distributed over wider area. Conclusion: The type of the occlusal teeth loading has the biggest influence on cervical stress intensity. Geometric shape of the existing lesion is very important in the distribution of internal stress. Compared to the U-shaped lesions, V-shaped lesions show significantly higher stress concentrations under load. Exposure to stress would lead to its progression.

2015 ◽  
Vol 41 (2) ◽  
pp. 163-171 ◽  
Author(s):  
Gianpaolo Sannino

The aim of this work was to study the biomechanical behavior of an All-on-4 implant-supported prosthesis through a finite element analysis comparing 3 different tilt degrees of the distal implants. Three-dimensional finite element models of an edentulous maxilla restored with a prosthesis supported by 4 implants were reconstructed to carry out the analysis. Three distinct configurations, corresponding to 3 tilt degrees of the distal implants (15°, 30°, and 45°) were subjected to 4 loading simulations. The von Mises stresses generated around the implants were localized and quantified for comparison. Negligible differences in von Mises stress values were found in the comparison of the 15° and 30° models. From a stress-level viewpoint, the 45° model was revealed to be the most critical for peri-implant bone. In all the loading simulations, the maximum stress values were always found at the neck of the distal implants. The stress in the distal implants increased in the apical direction as the tilt degree increased. The stress location and distribution patterns were very similar among the evaluated models. The increase in the tilt degree of the distal implants was proportional to the increase in stress concentration. The 45° model induced higher stress values at the bone-implant interface, especially in the distal aspect, than the other 2 models analyzed.


2018 ◽  
Vol 32 (4) ◽  
pp. 185
Author(s):  
Josué Ricardo Broilo ◽  
Evandro Afonso Sartori ◽  
Luiz Oscar Honorato Mariano ◽  
Leandro Corso ◽  
Rosemary Sadami Arai Shinkai

OBJECTIVE: This 3-D FEA study compared the stress distribution in two-implant mandibular overdentures as a function of implant position and attachment system (LA: locator attachment vs. BA: ball attachment).METHODS: Four models of mandibular overdentures were tested: M1-LA – with implants at the canine regions (standard implant position) and LA; M2-LA – with implants placed at the first premolar regions (distalized implant position) and LA; M1-BA – with standard implant position and BA; and M2-BA – with distalized implant position and BA. The geometric models were converted into finite element models. A 100 N axial load was applied at the first molar region. The von-Mises stress distribution was compared in selected points.RESULTS: The models with BA had pattern of stress distribution was more uniform along the implant axis than the ones with LA, although the stress magnitude was larger. The largest area of von Mises stresses on the alveolar ridge was in the models with standard implant distribution.CONCLUSION: The findings showed that the models with BA had better biomechanical behavior than the ones with LA. For both types of attachment, the models with increased inter-implant distance presented a smaller area of stress distribution in the perimplant cortical bone tissue than the standard implant position. 


2019 ◽  
Vol 45 (5) ◽  
pp. 363-370
Author(s):  
Gokce Soganci Unsal ◽  
Guzin Neda Hasanoglu Erbasar ◽  
Filiz Aykent ◽  
Ozgun Yusuf Ozyilmaz ◽  
Mahmut Sertac Ozdogan

The biomechanical behavior of the edentulous mandible with bone irregularities that has been rehabilitated with implant-supported overdentures has become an important factor for treatment planning. Restorative options, including dental implants with various attachments, affect the stress distribution. The purpose of this study was to evaluate the stress distribution of cortical bone around the implant neck and implant structures in overdentures with two different attachment types at the edentulous mandible and with different bone heights using three-dimensional finite element analysis. Five three-dimensional models of an edentulous mandible were designed and implemented. Ten models were constructed with ball and locator attachments. Static bilateral and unilateral vertical and oblique occlusal loads with magnitudes of 100 N were applied to the overdentures. The principal stresses were higher in the presence of oblique loads compared to vertical loads in all the analyzed models. Maximum principal stresses were observed around the mesial side of the contralateral implant, and the minimum principal stresses were noted around the distal side of ipsilateral implant during unilateral vertical loading. These patterns were reversed during oblique loadings. The ball attachment models yielded lower von Mises stress values than the locator models at all the loading conditions, while the stress distributions were similar in the models with the same and different bone levels. Correspondingly, bone corrections due to irregularities may not be necessary in terms of biomechanics. The results of this study may provide clinicians a better understanding for the mandibular overdenture design in the cases at which different bone heights exist.


Author(s):  
Nurullah Türker ◽  
Hümeyra Tercanlı Alkış ◽  
Steven J Sadowsky ◽  
Ulviye Şebnem Büyükkaplan

An ideal occlusal scheme plays an important role in a good prognosis of All-on-Four applications, as it does for other implant therapies, due to the potential impact of occlusal loads on implant prosthetic components. The aim of the present three-dimensional (3D) finite element analysis (FEA) study was to investigate the stresses on abutments, screws and prostheses that are generated by occlusal loads via different occlusal schemes in the All-on-Four concept. Three-dimensional models of the maxilla, mandible, implants, implant substructures and prostheses were designed according to the All-on-Four concept. Forces were applied from the occlusal contact points formed in maximum intercuspation and eccentric movements in canine guidance occlusion (CGO), group function occlusion (GFO) and lingualized occlusion (LO). The von Mises stress values for abutment and screws and deformation values for prostheses were obtained and results were evaluated comparatively. It was observed that the stresses on screws and abutments were more evenly distributed in GFO. Maximum deformation values for prosthesis were observed in the CFO model for lateral movement both in the maxilla and mandible. Within the limits of the present study, GFO may be suggested to reduce stresses on screws, abutments and prostheses in the All-on-Four concept.


Author(s):  
J. R. Beisheim ◽  
G. B. Sinclair ◽  
P. J. Roache

Current computational capabilities facilitate the application of finite element analysis (FEA) to three-dimensional geometries to determine peak stresses. The three-dimensional stress concentrations so quantified are useful in practice provided the discretization error attending their determination with finite elements has been sufficiently controlled. Here, we provide some convergence checks and companion a posteriori error estimates that can be used to verify such three-dimensional FEA, and thus enable engineers to control discretization errors. These checks are designed to promote conservative error estimation. They are applied to twelve three-dimensional test problems that have exact solutions for their peak stresses. Error levels in the FEA of these peak stresses are classified in accordance with: 1–5%, satisfactory; 1/5–1%, good; and <1/5%, excellent. The present convergence checks result in 111 error assessments for the test problems. For these 111, errors are assessed as being at the same level as true exact errors on 99 occasions, one level worse for the other 12. Hence, stress error estimation that is largely reasonably accurate (89%), and otherwise modestly conservative (11%).


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Charles Savoldelli ◽  
Elodie Ehrmann ◽  
Yannick Tillier

AbstractWith modern-day technical advances, high sagittal oblique osteotomy (HSOO) of the mandible was recently described as an alternative to bilateral sagittal split osteotomy for the correction of mandibular skeletal deformities. However, neither in vitro nor numerical biomechanical assessments have evaluated the performance of fixation methods in HSOO. The aim of this study was to compare the biomechanical characteristics and stress distribution in bone and osteosynthesis fixations when using different designs and placing configurations, in order to determine a favourable plating method. We established two finite element models of HSOO with advancement (T1) and set-back (T2) movements of the mandible. Six different configurations of fixation of the ramus, progressively loaded by a constant force, were assessed for each model. The von Mises stress distribution in fixations and in bone, and bony segment displacement, were analysed. The lowest mechanical stresses and minimal gradient of displacement between the proximal and distal bony segments were detected in the combined one-third anterior- and posterior-positioned double mini-plate T1 and T2 models. This suggests that the appropriate method to correct mandibular deformities in HSOO surgery is with use of double mini-plates positioned in the anterior one-third and posterior one-third between the bony segments of the ramus.


2021 ◽  
Vol 11 (18) ◽  
pp. 8629
Author(s):  
Li-Ren Chang ◽  
Ya-Pei Hou ◽  
Ting-Sheng Lin

The effectiveness of a single four-hole plate (S4HP), perpendicularly oriented four-hole and two-hole plate (Per4H2HP), and perpendicularly oriented double two-hole plate (PerD2HP) for the fixation of a mandibular fracture was studied. A finite element analysis of the mandibular symphysis fractures treated with S4HP, Per4H2HP, and PerD2HP was performed. All surface nodes were fixed in the mandibular condyle region and occlusal muscle forces were applied. The maximal von Mises stress (MaxVMS) values of the plates, screws and screw holes were investigated. The displacement of the fracture site on the lower border of the mandibular symphysis was recorded. The displacement on the lower border of the fracture sites in the S4HP group was greater than that in the Per4H2HP group and the PerD2HP group. There was no eversion at the fracture site among all groups. Both the S4HP and Per4H2HP groups showed stress concentrations on the screws close to the fracture site. The MaxVMS increased when the number of screw holes on the mandibular anterior lower border decreased. The displacement of the fracture site and eversion with Per4H2HP and PerD2HP were far lower than those with S4HP. PerD2HP is a stable and green fixation technique for mandibular symphysis fractures.


Author(s):  
Jifeng Wang ◽  
Qubo Li ◽  
Norbert Mu¨ller

A mechanical and optimal analyses procedure is developed to assess the stresses and deformations of Novel Wound Composite Axial-Impeller under loading conditions particular to centrifuge. This procedure is based on an analytical method and Finite Element Analysis (FEA, commercial software ANSYS) results. A low-cost, light-weight, high-performance, composite turbomachinery impeller from differently designed patterns will be evaluated. Such impellers can economically enable refrigeration plants using water as a refrigerant (R718). To create different complex patterns of impellers, MATLAB is used for creating the geometry of impellers, and CAD software UG is used to build three-dimensional impeller models. Available loading conditions are: radial body force due to high speed rotation about the cylindrical axis and fluid forces on each blade. Two-dimensional plane stress and three-dimensional stress finite element analysis are carried out using ANSYS to validate these analytical mechanical equations. The von Mises stress is investigated, and maximum stress and Tsai-Wu failure criteria are applied for composite material failure, and they generally show good agreement.


2018 ◽  
Vol 285 (1887) ◽  
pp. 20181473 ◽  
Author(s):  
Charlotte A. Brassey ◽  
James D. Gardiner ◽  
Andrew C. Kitchener

The baculum (os penis) is a mineralized bone within the glans of the mammalian penis and is one of the most morphologically diverse structures in the mammal skeleton. Recent experimental work provides compelling evidence for sexual selection shaping the baculum, yet the functional mechanism by which this occurs remains unknown. Previous studies have tested biomechanical hypotheses for the role of the baculum based on simple metrics such as length and diameter, ignoring the wealth of additional shape complexity present. For the first time, to our knowledge, we apply a computational simulation approach (finite-element analysis; FEA) to quantify the three-dimensional biomechanical performance of carnivoran bacula (n= 74) based upon high-resolution micro-computed tomography scans. We find a marginally significant positive correlation between sexual size dimorphism and baculum stress under compressive loading, counter to the ‘vaginal friction’ hypothesis of bacula becoming more robust to overcome resistance during initial intromission. However, a highly significant negative relationship exists between intromission duration and baculum stress under dorsoventral bending. Furthermore, additional FEA simulations confirm that the presence of a ventral groove would reduce deformation of the urethra. We take this as evidence in support of the ‘prolonged intromission’ hypothesis, suggesting the carnivoran baculum has evolved in response to pressures on the duration of copulation and protection of the urethra.


Sign in / Sign up

Export Citation Format

Share Document