scholarly journals PGS1, a new low cost and low power Portable Geo-physical Station “All in One”. Design and test

2020 ◽  
Vol 63 (Vol 63 (2020)) ◽  
Author(s):  
Antonio Costanza ◽  
Gioacchino Fertitta ◽  
William Yang ◽  
Giuseppe D'Anna ◽  
Claudio Chiarabba

PGS1 is a new compact portable seismic station, designed at INGV OBS and Earth Lab, that is specifically intended for the deployment of dense arrays of seismographs on-shore. With its low cost, compact design, high data-quality and long battery life, PGS1 is a perfect solution for seismic monitoring networks. PGS1 design is based on a solid polypropylene suitcase, containing a complete data acquisition system, two battery packs and a photovoltaic panel. The new Earth Lab 5s medium-period seismic sensor is included. The whole system meets the IP67 standard requirements both in transport and in acquisition configuration. PGS1 is normally equipped with one battery pack, one more pack can be added inside the suitcase achieving 40 days of battery life. The station is equipped with a photovoltaic panel, useful to extend the deployment length. Inside the suitcase, there are compartments where to store the seismic sensor, the photovoltaic panel and all the cables. Therefore, the station is very easy to transport.

Author(s):  
Laxmi Sharma

It is expected that internet of things (IoT) will deal with the major activities in the connected living environment as well as the industrial processes. All these aspects are going to be real in the frameworks of the fifth-generation (5G) mobile networks. 5G-based narrowband IoT (NB-IoT) networks have the capability to serve various innovative IoT applications at a great extent. NB-IoT is third generation partnership project (3GPP) standardized low power wide area (LPWA) technology which is designed for IoT devices requiring long battery life, low cost, worldwide coverage, and high system capacity. To improve the performance, 3GPP has agreed that the NB-IoT will continue evolving as part of the 5G specifications. NB-IoT along with 5G will work in several connected living applications. This combination will also be very useful in the industrial environments which need high data rates and low latency. All these features will be supported by 5G in the future. Similarly, applications with low data rates in the IoT world will be supported by NB-IoT. So 5G and NB-IoT are going to be a popular combination for several new applications.


2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
Lei Xu ◽  
Kama Huang

This paper presents a novel compact design of a low cost fully printable slot-loaded bowtie chipless RFID tag. The tag consists of two trapezoidal metallic patches loaded with multiple slot resonators. Slots with similar size or adjacent frequencies are loaded alternately on two bow-tie patches to double the number of data bits within the UWB frequency band without increasing the mutual coupling between slots. A coding capacity of 12 bits is obtained with 12 slots within a reasonable size of 35 mm×33 mm. RCS of the tag has been given by simulation. Measurements have been done using a bistatic radar configuration in the frequency domain and transmission coefficient is measured. The agreement between the simulation and measurement validates this new concept of design. This tag has high data capacity and low cost and can be directly printed on product such as personal ID, credit cards, paper, and textile because it needs only one conductive layer.


2015 ◽  
Vol 2 (2) ◽  
pp. 86-96 ◽  
Author(s):  
M. Zomorrodi ◽  
N.C. Karmakar

The electromagnetic (EM) imaging technique at mm-band 60 GHz is proposed for data encoding purpose in the chipless Radio Frequency Identification (RFID) systems. The fully printable chipless RFID tag comprises tiny conductive EM polarizers to create high cross-polar radar cross-section. Synthetic aperture radar approach is applied for formation of the tag's EM-image and revealing the tag's content. The achieved high data encoding capacity of 2 bits/cm2in this technique based on a fully printable tag is very convincing for many applications. The system immunity to multipath interference, bending effect, and printing inaccuracy suggests huge potentials for low-cost item tagging. Tags are also readable through a tick paper envelop; hence secure identification is provided by the proposed technique.


Author(s):  
Cheyma BARKA ◽  
Hanen MESSAOUDI-ABID ◽  
Houda BEN ATTIA SETTHOM ◽  
Afef BENNANI-BEN ABDELGHANI ◽  
Ilhem SLAMA-BELKHODJA ◽  
...  

2021 ◽  
Vol 27 (1) ◽  
Author(s):  
J. M. Lazarus ◽  
M. Ncube

Abstract Background Technology currently used for surgical endoscopy was developed and is manufactured in high-income economies. The cost of this equipment makes technology transfer to resource constrained environments difficult. We aimed to design an affordable wireless endoscope to aid visualisation during rigid endoscopy and minimally invasive surgery (MIS). The initial prototype aimed to replicate a 4-mm lens used in rigid cystoscopy. Methods Focus was placed on using open-source resources to develop the wireless endoscope to significantly lower the cost and make the device accessible for resource-constrained settings. An off the shelf miniature single-board computer module was used because of its low cost (US$10) and its ability to handle high-definition (720p) video. Open-source Linux software made monitor mode (“hotspot”) wireless video transmission possible. A 1280 × 720 pixel high-definition tube camera was used to generate the video signal. Video is transmitted to a standard laptop computer for display. Bench testing included latency of wireless digital video transmission. Comparison to industry standard wired cameras was made including weight and cost. The battery life was also assessed. Results In comparison with industry standard cystoscope lens, wired camera, video processing unit and light source, the prototype costs substantially less. (US$ 230 vs 28 000). The prototype is light weight (184 g), has no cables tethering and has acceptable battery life (of over 2 h, using a 1200 mAh battery). The camera transmits video wirelessly in near real time with only imperceptible latency of < 200 ms. Image quality is high definition at 30 frames per second. Colour rendering is good, and white balancing is possible. Limitations include the lack of a zoom. Conclusion The novel wireless endoscope camera described here offers equivalent high-definition video at a markedly reduced cost to contemporary industry wired units and could contribute to making minimally invasive surgery possible in resource-constrained environments.


Sensors ◽  
2021 ◽  
Vol 21 (6) ◽  
pp. 2254
Author(s):  
Francisco Javier González-Cañete ◽  
Eduardo Casilari

Over the last few years, the use of smartwatches in automatic Fall Detection Systems (FDSs) has aroused great interest in the research of new wearable telemonitoring systems for the elderly. In contrast with other approaches to the problem of fall detection, smartwatch-based FDSs can benefit from the widespread acceptance, ergonomics, low cost, networking interfaces, and sensors that these devices provide. However, the scientific literature has shown that, due to the freedom of movement of the arms, the wrist is usually not the most appropriate position to unambiguously characterize the dynamics of the human body during falls, as many conventional activities of daily living that involve a vigorous motion of the hands may be easily misinterpreted as falls. As also stated by the literature, sensor-fusion and multi-point measurements are required to define a robust and reliable method for a wearable FDS. Thus, to avoid false alarms, it may be necessary to combine the analysis of the signals captured by the smartwatch with those collected by some other low-power sensor placed at a point closer to the body’s center of gravity (e.g., on the waist). Under this architecture of Body Area Network (BAN), these external sensing nodes must be wirelessly connected to the smartwatch to transmit their measurements. Nonetheless, the deployment of this networking solution, in which the smartwatch is in charge of processing the sensed data and generating the alarm in case of detecting a fall, may severely impact on the performance of the wearable. Unlike many other works (which often neglect the operational aspects of real fall detectors), this paper analyzes the actual feasibility of putting into effect a BAN intended for fall detection on present commercial smartwatches. In particular, the study is focused on evaluating the reduction of the battery life may cause in the watch that works as the core of the BAN. To this end, we thoroughly assess the energy drain in a prototype of an FDS consisting of a smartwatch and several external Bluetooth-enabled sensing units. In order to identify those scenarios in which the use of the smartwatch could be viable from a practical point of view, the testbed is studied with diverse commercial devices and under different configurations of those elements that may significantly hamper the battery lifetime.


2014 ◽  
Vol 08 (02) ◽  
pp. 209-227 ◽  
Author(s):  
Håkon Kvale Stensland ◽  
Vamsidhar Reddy Gaddam ◽  
Marius Tennøe ◽  
Espen Helgedagsrud ◽  
Mikkel Næss ◽  
...  

There are many scenarios where high resolution, wide field of view video is useful. Such panorama video may be generated using camera arrays where the feeds from multiple cameras pointing at different parts of the captured area are stitched together. However, processing the different steps of a panorama video pipeline in real-time is challenging due to the high data rates and the stringent timeliness requirements. In our research, we use panorama video in a sport analysis system called Bagadus. This system is deployed at Alfheim stadium in Tromsø, and due to live usage, the video events must be generated in real-time. In this paper, we describe our real-time panorama system built using a low-cost CCD HD video camera array. We describe how we have implemented different components and evaluated alternatives. The performance results from experiments ran on commodity hardware with and without co-processors like graphics processing units (GPUs) show that the entire pipeline is able to run in real-time.


Sensors ◽  
2018 ◽  
Vol 18 (7) ◽  
pp. 2382 ◽  
Author(s):  
Antonio Vidal-Pardo ◽  
Santiago Pindado

In this work, a new and low-cost Arduino-Based Data Acquisition System (ABDAS) for use in an aerodynamics lab is developed. Its design is simple and reliable. The accuracy of the system has been checked by being directly compared with a commercial and high accuracy level hardware from National Instruments. Furthermore, ABDAS has been compared to the accredited calibration system in the IDR/UPM Institute, its measurements during this testing campaign being used to analyzed two different cup anemometer frequency determination procedures: counting pulses and the Fourier transform. The results indicate a more accurate transfer function of the cup anemometers when counting pulses procedure is used.


Sensors ◽  
2021 ◽  
Vol 21 (23) ◽  
pp. 7919
Author(s):  
Sjoerd van Ratingen ◽  
Jan Vonk ◽  
Christa Blokhuis ◽  
Joost Wesseling ◽  
Erik Tielemans ◽  
...  

Low-cost sensor technology has been available for several years and has the potential to complement official monitoring networks. The current generation of nitrogen dioxide (NO2) sensors suffers from various technical problems. This study explores the added value of calibration models based on (multiple) linear regression including cross terms on the performance of an electrochemical NO2 sensor, the B43F manufactured by Alphasense. Sensor data were collected in duplicate at four reference sites in the Netherlands over a period of one year. It is shown that a calibration, using O3 and temperature in addition to a reference NO2 measurement, improves the prediction in terms of R2 from less than 0.5 to 0.69–0.84. The uncertainty of the calibrated sensors meets the Data Quality Objective for indicative methods specified by the EU directive in some cases and it was verified that the sensor signal itself remains an important predictor in the multilinear regressions. In practice, these sensors are likely to be calibrated over a period (much) shorter than one year. This study shows the dependence of the quality of the calibrated signal on the choice of these short (monthly) calibration and validation periods. This information will be valuable for determining short-period calibration strategies.


2012 ◽  
Vol 571 ◽  
pp. 324-327
Author(s):  
A Qi Yan ◽  
Deng Shan Wu ◽  
Hao Wang ◽  
Jian Zhong Cao ◽  
Jing Jin Ma ◽  
...  

Infrared zoom lens system with cooled focal plane array (FPA) detector is widely used in military application. Relevant information about optical design can be got easily, but research on infrared zoom lens system with low cost and high image quality for commercial application is less. This paper design a Compact infrared zoom lens system with only four lenses, using an uncooled focal plane array (FPA) with 384×288 pixels with zoom ratio 3:1. Because of large F number and less lenses, transmission of the whole zoom system is greatly improved. NETD and MRTD of infrared system will be satisfying by this compact design. There is no special surface such as diffractive surface, HOE in zoom lens system, and only Ge and Znse infrared materials are chosen which result in lower production cost of infrared zoom lens system for commercial applications.


Sign in / Sign up

Export Citation Format

Share Document