scholarly journals Electromechanical Characteristics of Core Free Folded Dielectric Electro-active Polymer Soft Actuator

2021 ◽  
Vol 29 (3) ◽  
Author(s):  
Abdul Malek Abdul Wahab ◽  
Muhamad Azhan Anuar ◽  
Muhamad Sukri Hadi

This paper investigates the active dynamic and electromechanical characteristics of a new thin folded dielectric electro-active polymer actuator developed by Danfoss PolyPower. The high voltage is supplied to the actuator during dynamic testing to identified the effect of the electrical field on dynamic characteristics. The electromechanical characteristics are investigated by varying the amplitude and frequency of the voltage supplied. The experimental results, such as natural frequency, amplitude response, and loss factor are presented to show the influence of such an electrical field on the characteristic of the actuator. There is a reduction of resonance frequency from 14 Hz to 12 Hz as voltage supply up to 2000 V. The actuating response of the actuator was subjected more to frequency rather than the amplitude of the voltage supplied. Hence, the results may guide the exploration of a new folded thin actuator as an active vibration controller.

2020 ◽  
Vol 14 (4) ◽  
pp. 7396-7404
Author(s):  
Abdul Malek Abdul Wahab ◽  
Emiliano Rustighi ◽  
Zainudin A.

Various complex shapes of dielectric electro-active polymer (DEAP) actuator have been promoted for several types of applications. In this study, the actuation and mechanical dynamics characteristics of a new core free flat DEAP soft actuator were investigated. This actuator was developed by Danfoss PolyPower. DC voltage of up to 2000 V was supplied for identifying the actuation characteristics of the actuator and compare with the existing formula. The operational frequency of the actuator was determined by dynamic testing. Then, the soft actuator has been modelled as a uniform bar rigidly fixed at one end and attached to mass at another end. Results from the theoretical model were compared with the experimental results. It was found that the deformation of the current actuator was quadratic proportional to the voltage supplied. It was found that experimental results and theory were not in good agreement for low and high voltage with average percentage error are 104% and 20.7%, respectively. The resonance frequency of the actuator was near 14 Hz. Mass of load added, inhomogeneity and initial tension significantly affected the resonance frequency of the soft actuator. The experimental results were consistent with the theoretical model at zero load. However, due to inhomogeneity, the frequency response function’s plot underlines a poor prediction where the theoretical calculation was far from experimental results as values of load increasing with the average percentage error 15.7%. Hence, it shows the proposed analytical procedure not suitable to provide accurate natural frequency for the DEAP soft actuator.


2016 ◽  
Vol 2016 ◽  
pp. 1-11 ◽  
Author(s):  
Andrzej Dymarek ◽  
Tomasz Dzitkowski

The paper presents the problem of discrete vibration reduction in mechanical systems depending on the desired dynamic properties. The conditions for physical feasibility of dynamic characteristics have been defined, in the form of impedance and mobility, for passive and active vibration reduction. The authors have presented a graphic method for determining the free vibration drop coefficient, based on the desired value of the reduced resonance frequency amplitude.


Author(s):  
Tae Ho Kim ◽  
Moon Sung Park ◽  
Jongsung Lee ◽  
Young Min Kim ◽  
Kyoung-Ku Ha ◽  
...  

Gas foil bearings (GFBs) have clear advantages over oil-lubricated and rolling element bearings, by virtue of low power loss, oil-free operation in compact units, and rotordynamic stability at high speeds. However, because of the inherent low gas viscosity, GFBs have lower load capacity than the other bearings. In particular, accurate measurement of load capacity and dynamic characteristics of gas foil thrust bearings (GFTBs) is utmost important to widening their applications to high performance turbomachinery. In this study, a series of excitation tests were performed on a small oil-free turbomachinery with base excitations in the rotor axial direction to measure the dynamic load characteristics of a pair of six-pad, bump-type GFTBs, which support the thrust collar. An electromagnetic shaker provided dynamic sine sweep loads to the test bench (shaking table), which held rigidly the turbomachinery test rig for increasing excitation frequency from 10 Hz to 200 Hz. The magnitude of the shaker dynamic load, represented as an acceleration measured on the test rig, was increased up to 9 G (gravity). An eddy current sensor installed on the test rig housing measured the axial displacement (or vibrational amplitude) of the rotor thrust collar during the excitation tests. The axial acceleration of the rotor relative to the test rig was calculated using the measured displacement. A single degree-of-freedom base excitation model identified the frequency-dependent dynamic load capacity, stiffness, damping, and loss factor of the test GFTB for increasing shaker dynamic loads and increasing bearing clearances. The test results show that, for a constant shaker force and the test GFTB with a clearance of 155 μm, an increasing excitation frequency increases the dynamic load carried by the test GFTB, i.e., bearing reaction force, until a certain value of the frequency where it jumps down suddenly because of the influence from Duffing’s vibrations of the rotor. The bearing stiffness increases and the damping decreases dramatically as the excitation frequency increases. Generally, the bearing loss factor ranges from 0.5 to 1.5 independent of the frequency. As the shaker force increases, the bearing dynamic load, stiffness, damping, and loss factor increase depending on the excitation frequency. Interestingly, the agreements between the measured GFTB dynamic load versus the thrust runner displacement, the measured GFTB static load versus the structural deflection, and the predicted static load versus the thrust runner displacement are remarkable. Further tests with increasing GFTB clearances of 155, 180, 205, and 225 μm revealed that the vibrational amplitude increases and the jump-down frequency decreases with increasing clearances. The bearing load increases, but the bearing stiffness, damping, and loss factor decrease slightly as the clearance increases. The test results after a modification of the GFTB by rotating one side bearing plate by 30° relative to the other side bearing plate revealed insignificant changes in the dynamic characteristics. The present dynamic performance measurements provide a useful database of GFTBs for use in microturbomachinery.


Author(s):  
M.I. Yalandin ◽  
K.A. Sharypov ◽  
V.G. Shpak ◽  
S.A. Shunailov ◽  
A.G. Reutova ◽  
...  

Author(s):  
John F. Donlon ◽  
Eric R. Motto ◽  
Eugen Wiesner ◽  
Eugen Stumpf ◽  
Shinichi Iura ◽  
...  

Author(s):  
А.В. Саврико ◽  
С.Н. Лымич ◽  
К.В. Кружаев ◽  
В.С. Левин ◽  
А.В. Москвичев

Приведено исследование зависимости газодинамических характеристик стенда от применяемого материала трубопровода. Oсновополагающими факторами, влияющими на работоспособность стенда, являются выходные параметры - давление и расход рабочего тела, которые напрямую зависят от потерь давления на трение, создаваемого элементами стенда. Для оценки степени влияния материалов на потери стенда выбраны два вида труб: полипропиленовые и металлические. Аналитические расчёты потери давления рассматриваемых трубопроводов из различного материала показали, что трубопроводы из полипропилена предпочтительнее. Однако при проведении эксперимента получены противоположные данные, которые показали, что в полипропиленовых магистралях возможно присутствие значительного количества диафрагм: в местах пайки труб, образовавшихся в процессе изготовления. Именно этот факт способствует существенному повышению значений сопротивлений в полипропиленовых трубопроводах на 20 % по сравнению со стальными трубами, где диафрагмы отсутствуют. В результате проведения исследования был введен коэффициент, учитывающий влияние диафрагм полипропиленового трубопровода при аналитическом расчете на сопротивление. Для сохранения более точных снимаемых значений с газодинамических стендов целесообразнее использовать трубопроводы из металла, в которых рассчитать потери возможно с отклонениями до 3 % Here we give the study of the dependence of the gas-dynamic characteristics of the stand on the pipeline material used. The fundamental factors affecting the performance of the stand are the output parameters-the pressure and flow rate of the working fluid, which directly depend on the friction pressure losses created by the elements of the stand. To assess the degree of influence of materials on the losses of the stand, we selected two types of pipes: polypropylene and metal. Analytical calculations of the pressure loss of the considered pipelines made of various materials have shown that pipelines made of polypropylene are preferable. However, during the experiment, we obtained the opposite data, which showed that a significant number of diaphragms may be present in polypropylene pipelines: in the places of soldering of pipes formed during the manufacturing process. This fact contributes to a significant increase in the resistance values in polypropylene pipelines by 20 % compared to steel pipes, where there are no diaphragms. As a result of the study, we introduced a coefficient that takes into account the influence of polypropylene pipeline diaphragms in the analytical calculation of resistance. To preserve more accurate values taken from gas-dynamic stands, it is more expedient to use metal pipelines in which it is possible to calculate losses with deviations of up to 3 %


2017 ◽  
Vol 10 (1) ◽  
Author(s):  
N. Othman ◽  
A. Ahmad ◽  
M. A. Piramali

Demulsification is one of the key processes in emulsion liquid membrane application. This study involved the effect of electrical field on demulsification of water in oil using batch high voltage demulsifier system. This technique widely used because of its advantages of easy manipulation of applied field direction and strength, offers cost–effective separation and minimal environmental impact combined with mechanical simplicity. Influence of various values of frequency (400–1500 Hz) and voltage was studied experimentally using Alternate Current (AC) High Voltage Demulsifier with insulated electrode. The emulsion consists of kerosene as organic phase, sulfuric acid as internal phase and span 80 (3 and 5 w/v %) as a surfactant. The effect of emulsion preparation such as homogenizer speed, internal phase and surfactant concentrations on the stability of water–in–oil emulsion was also investigated. The results showed that the attractive forces between the water droplets under an electrical field increase by raising the applied electrical field strength. Meanwhile, the time required for the emulsion to separate and coalescence under electrical field increased when the stability of emulsion increased.


Sign in / Sign up

Export Citation Format

Share Document