scholarly journals Emerging Antibacterial Coated Dental Implants: A Preventive Measure for Peri-implantitis

2016 ◽  
Vol 7 (4) ◽  
pp. 195-198 ◽  
Author(s):  
Varun Yarramaneni ◽  
Dhanasekar Balakrishnan ◽  
IN Aparna ◽  
Akanksha Sachdeva ◽  
Nayana Prabhu

ABSTRACT Dental implants are the modern marvel and are widely accepted as a reconstructive treatment modality for tooth replacement. In recent times, there has been a marked progress in the clinical success rates of dental implants, but implant failures as a result of infections are continuing at an alarming rate of 8% per year, translating into 1 million failures worldwide. Perimucositis and peri-implantitis are the chief complications reported postimplant surgery that effects its short- and long-term success. Peri-implantitis is characterized by clinical and radiological bone loss around the implant accompanied with an inflammatory reaction of the peri-implant mucosa and is an irreversible condition, whereas perimucositis is a reversible inflammatory change. Implant surfaces provide an ideal substrate for bacterial adhesion forming a biofilm. Biofilm performs vast functions ranging from physical defensive barrier against phagocytic predation to working as a selective permeable barrier. This limits the diffusion of systemic antimicrobial agents that are capable of damaging the bacterial complexes. These rapidly growing bacteria give rise to a chronic infection which is difficult to eradicate by conventional antibiotic therapy. To inhibit peri-implant infections, various functional modifications in the implant surfaces have been suggested. The coatings on the titanium implant are incorporated with disinfectants, antibiotics as well as antimicrobial peptides AMPs. This paper is an attempt to review all the antibiotic coatings available for a titanium implant and discuss their prospective future to prevent peri-implant infections. How to cite this article Yarramaneni V, Aparna IN, Sachdeva A, Balakrishnan D, Prabhu N. Emerging Antibacterial Coated Dental Implants: A Preventive Measure for Peri-implantitis. World J Dent 2016;7(4):195-198.

Author(s):  
Mitova D

Aim: To study the short-and long-term results of 2RT nanosecond laser treatment for CSC. To compare clinical results with those with AntiVEGF. Methods: Nanosecond laser (2RT, Ellex) was used. Patients were followed by BCVA, FAF, OCT, Angio-OCT. Results: 90% of the patient treated with 2RT had improvement of visual acuity and contrast sensitivity. 19 % [1] patients showed no improvement. 81% of the 2RT treated patients had total resorbtion of subretinal fluid against 60% treated with AntiVEGF. Functional results correlated with the atrophy of RPE in the macula. 46% (19 patients) had resolution on the first month, 23% [2]-on the third and 12% [3]-on the sixth month. The time of resolution shows no relation to the baseline pigment epithelial atrophy. Four patients presented with a recurrency of the disease in the follow-up period. 19% [1] were non responders. 60% of AntiVEGF treated eyes were responders and 40% were non responders. Those who responded to treatment needed between 3 and 10 injections. Conclusion: 2 RT is a non-invasive treatment modality with no adverse effects and high success rates.


2021 ◽  
Vol 35 (2) ◽  
pp. 140-146
Author(s):  
Lima Asrin Sayami ◽  
Al Fazir Omar ◽  
Sheikh Ziarat Islam ◽  
Subasni Govindan ◽  
Zulaikha Zainal ◽  
...  

Objective: Despite the evolution of interventional techniques and operator experience, percutaneous revascularization of complex coronary lesions especially calcified lesions remains challenging because of lower procedural success and higher restenosis rates. Limited data are available on the effect of rotational atherectomy (RA) plus stenting in the treatment of complex calcified lesions of coronary artery disease. This study was aimed to investigate the characteristics, short and long term outcomes in patients undergoing RA. Material and Methods: A database search was performed from the year 2008 to 2013 in National Heart institute, Malaysia. A total of 16009 patients who underwent PCIs were enrolled in 2 groups, RA group (258 patients) and non RA group (15751 patients). The Chi square test and Kaplan - Meier analysis were used. Results: Male patients (73.6%) and elderly population (63.2%) were predominant in this study.The RA group had more co-morbidities such as diabetic on insulin (34%) and chronic kidney disease (57%). The lesions in RA group were more complex with higher Type C lesion (68.8%) and longer lesion (20.6%) compared to non RA group. Despite higher patient risk profile, the success rate of revascularization remains high in RA group (99.3%) as in non RA group (97%) (p value 0.89%). More importantly there were no significant difference in in-hospital mortality, myocardial infarction and stent thrombosis in both group (p value 0.1). In 1 year Kaplan - Meier survival graph, there were better survival noted in non RA group (97.7%) compare to RA (89.6%) (p value <0.005), Conclusion: The use of RA allows debulking of a calcified lesion and possibly explains the higher acute procedural success rates. However, the lower 1-yearsurvival in the RA group highlights the higher associated baseline comorbitidity in this group. Therefore, besides coronary intervention, this RA group requires aggressive medical therapy through a multi-disciplinary approach. Bangladesh Heart Journal 2020; 35(2) : 140-146


2019 ◽  
Vol 53 (4) ◽  
pp. 284-291
Author(s):  
Hirokazu Onishi ◽  
Toru Naganuma ◽  
Koji Hozawa ◽  
Tomohiko Sato ◽  
Hisaaki Ishiguro ◽  
...  

Introduction: The purpose of the current study was to investigate the periprocedural and long-term outcomes of stent implantation for de novo subclavian artery (SCA) disease. Material and Methods: We retrospectively investigated consecutive patients with de novo SCA lesions undergoing elective endovascular therapy procedures at our center between April 2004 and September 2015. All patients were included in the analyses of periprocedural outcomes, including procedural and clinical success. Subsequently, patients who completed the clinical follow-up and were assessed with brachial systolic pressure differences between the diseased and the contralateral arms, or angiographic stenosis, after stent implantation with procedural success were included in the analyses of long-term outcomes, including primary patency. Results: There were 62 patients (median 71.0 years, interquartile range 65.3-76.0 years; 45 men) with 62 de novo SCA lesions included in the analyses of periprocedural outcomes. There were 46 stenoses (74.2%) and 16 occlusions (25.8%). Our results indicated high procedural success rates for overall (95.2%), stenotic (97.8%), and occlusive (87.5%) lesions. Similarly, high clinical success rates were observed for overall (91.9%), stenotic (93.5%), and occlusive (87.5%) lesions. The median follow-up time was 6.0 years (interquartile range, 2.6-8.3 years). There were 48 patients with 48 de novo SCA lesions included in the analyses of long-term outcomes. Primary patency estimates were 97.7% (1 year), 97.7% (3 years), 93.1% (5 years), and 87.6% (7 years). Also, we observed a high estimate for freedom from reintervention for the target vessel (93.8%). Conclusion: Stent implantation for de novo SCA disease can be performed successfully and safely with favorable periprocedural and long-term outcomes.


BMC Surgery ◽  
2019 ◽  
Vol 19 (1) ◽  
Author(s):  
Bernhard Kraemer ◽  
Christos Tsaousidis ◽  
Stephan Kruck ◽  
Martin Schenk ◽  
Marcus Scharpf ◽  
...  

Abstract Background Electrosurgical vessel sealers are gradually replacing conventional techniques such as ligation and clipping. Algorithms that control electrosurgical units (ESU), known as modes, are important for applications in different surgical disciplines. This chronic porcine animal study aimed to evaluate the safety and effectiveness of the novel thermoSEAL electrosurgical vessel sealing mode (TSM). The BiClamp® mode (BCM) of the renowned VIO® 300 D ESU served as control. BCM has been widely available since 2002 and has since been successfully used in many surgical disciplines. The TSM, for the novel VIO® 3 ESU, was developed to reduce sealing time and/or thermal lateral spread adjacent to the seal while maintaining clinical success rates. The primary aim of this study was to investigate the long-term and intraoperative seal quality of TSM. Methods The BiCision® device was used for vessel sealing with TSM and BCM in ten German Landrace pigs which underwent splenectomy and unilateral nephrectomy during the first intervention of the study. The seals were cut with the BiCision® knife. Ninety-nine arteries, veins and vascular bundles were chronically sealed for 5 or 21 days. Thereafter, during the second and terminal intervention of the study, 97 additional arteries and veins were sealed. The carotid arteries were used for histological evaluation of thermal spread. Results After each survival period, no long-term complications occurred with either mode. The intraoperative seal failure rates, i.e. vessel leaking or residual blood flow after the first sealing activation, were 2% with TSM versus 6% with BCM (p = 0.28). The sealing time was significantly shorter with TSM (3.5 ± 0.69 s vs. 7.3 ± 1.3 s, p < 0.0001). The thermal spread and burst pressure of arteries sealed with both modes were similar (p = 0.18 and p = 0.61) and corresponded to the histological evaluation. The measured tissue sticking parameter was rare with both modes (p = 0.33). Tissue charring did not occur. Regarding the cut quality, 97% of the seals were severed in the first and 3% in the second attempt (both with TSM and BCM). Conclusions The novel TSM seals blood vessels twice as fast as the BCM while maintaining excellent tissue effect and clinical success rates. Trial registration Not applicable.


EP Europace ◽  
2020 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
P Kupo ◽  
R Pap ◽  
G Bencsik ◽  
L Saghy

Abstract Introduction Catheter ablation of perimitral flutter can be challenging, owing to difficult anatomy. The most commonly applied procedure is the creation of a mitral isthmus line (between the lower left pulmonary vein and the mitral anulus) or an anteroseptal line (between the upper right pulmonary vein and the anterior mitral anulus). Purpose Our study aimed to compare the short and long term efficacy of two different ablation methods. Methods In our retrospective study 45 consecutive patients diagnosed with perimitral flutter were included between 2009 and 2018. Results Radiofrequency ablation was performed in 48 cases in 31 patients (mitral isthmus line (n = 25, 52.1%); anteroseptal line (n = 23, 47.9%)). Arrhythmia-termination and sinus rhythm restoration could be achieved in 64.6% of the cases (mitral isthmus line: 16/25 (64.0%), anteroseptal line: 15/23 (65.2%). Comparing two different techniques, there was no significant difference (p = 0.85) in acute success rates. During 24.3 months of follow-up period, in 60.0% of the patients no recurrence occurred. The arrhythmia recurred in 6 cases (40.0%) after anteroseptal line ablation, and in 8 cases (53.3%) after mitral isthmus line ablation. No difference was found in the long term efficiency of two  different ablation techniques (p = 0.211). Conclusion In our retrospective study we found no significant difference in the short and long term efficiency of two different therapeutic approaches to perimitral atrial flutter.


2017 ◽  
Vol 43 (3) ◽  
pp. 240-244 ◽  
Author(s):  
Zahi Badran ◽  
Xavier Struillou ◽  
Francis J Hughes ◽  
Assem Soueidan ◽  
Alain Hoornaert ◽  
...  

For decades titanium has been the preferred material for dental implant fabrication, with mechanical and biological performance resulting in high clinical success rates. These have been further enhanced by incremental development of surface modifications aimed at improving speed and degree of osseointegration and resulting in enhanced clinical treatment options and outcomes. However, increasing demand for metal-free dental restorations has also led to the development of ceramic-based dental implants, such as zirconia. In orthopedics, alternative biomaterials, such as polyetheretherketone or silicon nitride, have been used for implant applications. The latter is potentially of particular interest for oral use as it has been shown to have antibacterial properties. In this article we aim to shed light on this particular biomaterial as a future promising candidate for dental implantology applications, addressing basic specifications required for any dental implant material. In view of available preclinical data, silicon nitride seems to have the essential characteristics to be a candidate for dental implants material. This novel ceramic has a surface with potentially antimicrobial properties, and if this is confirmed in future research, it could be of great interest for oral use.


2018 ◽  
pp. 17-24
Author(s):  
Vagner Rossato Pegoraro ◽  
Eduardo Rodrigues Bento Costa ◽  
Luiz Fernando Fagundes Gouvea Filho ◽  
Beatriz Tose Costa Paiva

Introduction: The obtaining of venous access for implantation of implantable electronic cardiac devices (IECDs) has been traditionally made by intrathoracic subclavian vein puncture (SVP) or cephalic vein phlebotomy (CVP). Evidence indicates, however, the increased risk of short-term and long-term complications with SVP due to the fact that it is intrathoracic access and the risk of compression of the electrodes by the costoclavicular ligament, leading to different types of defects. CVP, in turn, has been associated with a failure rate that reaches 45%. Axillary vein puncture (AVP) has been described in the literature and is presented here as an alternative to the two techniques mentioned. Methods: A PubMed survey was conducted on articles that mention the AVP, SVP and CVP techniques and compare them to the immediate, short and long term results and success rates for obtaining venous access. Emphasis was placed on comparisons between the various AVP techniques. Conclusion: The AVP technique for obtaining venous access presents some variations among the different authors. It has CVP-like safety, success rates comparable to those of the subclavian vein, and better medium and long term results for electrode function.


Prosthesis ◽  
2020 ◽  
Vol 2 (2) ◽  
pp. 100-116 ◽  
Author(s):  
John W. Nicholson

The topic of titanium alloys for dental implants has been reviewed. The basis of the review was a search using PubMed, with the large number of references identified being reduced to a manageable number by concentrating on more recent articles and reports of biocompatibility and of implant durability. Implants made mainly from titanium have been used for the fabrication of dental implants since around 1981. The main alloys are so-called commercially pure titanium (cpTi) and Ti-6Al-4V, both of which give clinical success rates of up to 99% at 10 years. Both alloys are biocompatible in contact with bone and the gingival tissues, and are capable of undergoing osseointegration. Investigations of novel titanium alloys developed for orthopaedics show that they offer few advantages as dental implants. The main findings of this review are that the alloys cpTi and Ti-6Al-4V are highly satisfactory materials, and that there is little scope for improvement as far as dentistry is concerned. The conclusion is that these materials will continue to be used for dental implants well into the foreseeable future.


2019 ◽  
Vol 29 (5) ◽  
pp. 663-669 ◽  
Author(s):  
Etem Caliskan ◽  
Matthias Eberhard ◽  
Volkmar Falk ◽  
Hatem Alkadhi ◽  
Maximilian Y Emmert

Abstract OBJECTIVES High success rates for left atrial appendage (LAA) exclusion with the AtriClip (Atricure, USA) device have been reported in the literature. This study evaluated the presence and characteristics of residual LAA stumps after AtriClip LAA exclusion using postoperative short- and long-term computed tomography angiography (CTA). METHODS In this retrospective analysis, 43 of 291 consecutive patients undergoing cardiac surgery with concomitant LAA occlusion using the AtriClip device were identified with available postoperative short- and long-term follow-up by CTA. LAA patency and the absence or the size of a present residual LAA stump were assessed on 2-dimensional multiplanar reconstructions, on maximum intensity projection images and on volume-rendered 3-dimensional computed tomography reconstructions. Based on current recommendations, the threshold for a significant LAA stump length was defined <10 mm. RESULTS The LAA was successfully occluded in all 43 patients (100%) as confirmed by intraoperative transoesophageal echocardiography and CTA imaging with a mean follow-up duration of 7.1 ± 0.8 years post-implant. The absence of blood flow in the excluded LAA was confirmed in all cases. In 31 of 43 patients (72%), no residual stump (0 mm) was observed creating a smooth endocardial surface, CTA revealed residual LAA stumps in 11/43 patients (26%) with a length <10 mm and a significant residual stump with a depth of >10 mm (12 mm) in 1 patient (2%). The mean length, width and depth of the residual stumps were 5.8 ± 2.1, 4.4 ± 1.2 and 7.3 ± 2.3 mm, respectively. CONCLUSIONS This study investigated the incidence of residual stump formation (>10 mm) after LAA closure with the AtriClip device based on CTA imaging data obtained during short- and long-term follow-up. While no LAA stump was detectable in the majority of patients, a non-significant LAA stump (<10 mm) was present in 26% of cases, indicating a favourable LAA occlusion profile for the AtriClip device. However, although a LAA stump length <10 mm is currently considered clinically safe, this definition needs further attention in future studies with regards to its potential clinical implications.


2017 ◽  
Vol 45 (2) ◽  
pp. 706-713 ◽  
Author(s):  
Chengen Wang ◽  
Min Yang ◽  
Xiaoqiang Tong ◽  
Jian Wang ◽  
Haitao Guan ◽  
...  

Objective To evaluate the long-term efficacy and safety of selective arterial embolization (SAE) in the treatment of renal angiomyolipomas (AMLs). Methods This was a retrospective review of medical records and imaging findings from patients with renal AMLs who attended our clinic and received SAE between January 2007 and January 2014. Only patents with complete medical records, preoperative computed tomography scans using typical imaging and follow-up data were included. Results A total of 79 patients were enrolled in the study. Technical and clinical success rates were 100% and 91% ( n = 72), respectively. Only two patients experienced major complications. Post-embolization syndrome (i.e. fever, abdominal pain, nausea or vomiting) was reported in 68 (86%) patients, but all symptoms were mild and resolved with conservative measures. Mean radiological and clinical follow-up periods were 16.8 and 35.9 months, respectively. In 75 (95%) patients, tumours decreased in size; mean ± SD tumour size significantly decreased from 8.4 ± 3.5 cm pre-embolization to 6.7 ± 3.0 cm post-embolization . Conclusions This study provides long-term evidence that SAE is a safe and effective method in the treatment of patients with renal AMLs.


Sign in / Sign up

Export Citation Format

Share Document