scholarly journals Supplementary material to "Long-term behavior and stability of calibration models for NO and NO<sub>2</sub> low cost sensors"

Author(s):  
Horim Kim ◽  
Michael Müller ◽  
Stephan Henne ◽  
Christoph Hüglin
2019 ◽  
Vol 12 (2) ◽  
pp. 903-920 ◽  
Author(s):  
Carl Malings ◽  
Rebecca Tanzer ◽  
Aliaksei Hauryliuk ◽  
Sriniwasa P. N. Kumar ◽  
Naomi Zimmerman ◽  
...  

Abstract. Assessing the intracity spatial distribution and temporal variability in air quality can be facilitated by a dense network of monitoring stations. However, the cost of implementing such a network can be prohibitive if traditional high-quality, expensive monitoring systems are used. To this end, the Real-time Affordable Multi-Pollutant (RAMP) monitor has been developed, which can measure up to five gases including the criteria pollutant gases carbon monoxide (CO), nitrogen dioxide (NO2), and ozone (O3), along with temperature and relative humidity. This study compares various algorithms to calibrate the RAMP measurements including linear and quadratic regression, clustering, neural networks, Gaussian processes, and hybrid random forest–linear regression models. Using data collected by almost 70 RAMP monitors over periods ranging up to 18 months, we recommend the use of limited quadratic regression calibration models for CO, neural network models for NO, and hybrid models for NO2 and O3 for any low-cost monitor using electrochemical sensors similar to those of the RAMP. Furthermore, generalized calibration models may be used instead of individual models with only a small reduction in overall performance. Generalized models also transfer better when the RAMP is deployed to other locations. For long-term deployments, it is recommended that model performance be re-evaluated and new models developed periodically, due to the noticeable change in performance over periods of a year or more. This makes generalized calibration models even more useful since only a subset of deployed monitors are needed to build these new models. These results will help guide future efforts in the calibration and use of low-cost sensor systems worldwide.


2018 ◽  
Author(s):  
Carl Malings ◽  
Rebecca Tanzer ◽  
Aliaksei Hauryliuk ◽  
Sriniwasa P. N. Kumar ◽  
Naomi Zimmerman ◽  
...  

Abstract. Assessing the intra-city spatial distribution and temporal variability of air quality can be facilitated by a dense network of monitoring stations. However, the cost of implementing such a network can be prohibitive if traditional high-quality, expensive monitoring systems are used. To this end, the Real-time Affordable Multi-Pollutant (RAMP) monitor has been developed, which can measure up to five gases including the criteria pollutant gases carbon monoxide (CO), nitrogen dioxide (NO2), and ozone (O3), along with temperature and relative humidity. This study compares various algorithms to calibrate the RAMP measurements including linear and quadratic regression, clustering, neural networks, Gaussian processes, and random forests. Using data collected by more than sixty RAMP monitors over periods ranging up to eighteen months, it was found that quadratic regression models or a hybrid of random forest and linear models tend to be the most effective calibration models overall. In specific cases, other types of models can have comparable or even superior performance. Furthermore, generalized calibration models may be used instead of individual models with only a small reduction in overall performance. For long-term deployments, it is recommended that new models be developed each year, due to the noticeable change in performance when models for one year were used for processing data collected in the subsequent year. This makes annually-developed generalized calibration models even more useful since only a subset of deployed monitors are needed to build these models. These results will help guide future efforts in the calibration and use of low-cost sensor systems worldwide.


2018 ◽  
Vol 882 ◽  
pp. 190-198
Author(s):  
Julian Schirmer ◽  
Jewgeni Roudenko ◽  
Marcus Reichenberger

Digital printing technologies are becoming increasingly important for modern electronics production. Besides inkjet printing for low viscosity inks, jetting of pasty materials such as PTF can be a viable alternative to traditional subtractive or additive metallization methods in the future. Hybrid printed electronics, a combination of printed circuitry with classical electronic components, offers many advantages such as low cost, environmental sustainability and others. Until now, the mechanical and electrical properties of printed pastes on molded substrates have not been investigated in detail, just as little as the long-term characteristics of interconnection technologies necessary to mount traditional electronic components onto printed substrates. In different test series, electrical resistance and adhesion of a special PTF material have been investigated. The long-term behavior of the material itself and three alternative interconnection technologies for mounting of SMT components has been evaluated. Results are encouraging, although still a lot of improvements are necessary.


Author(s):  
Carl Malings ◽  
Rebecca Tanzer ◽  
Aliaksei Hauryliuk ◽  
Provat K. Saha ◽  
Allen L. Robinson ◽  
...  

Sensors ◽  
2021 ◽  
Vol 21 (12) ◽  
pp. 4214
Author(s):  
Christopher Zuidema ◽  
Cooper S. Schumacher ◽  
Elena Austin ◽  
Graeme Carvlin ◽  
Timothy V. Larson ◽  
...  

We designed and built a network of monitors for ambient air pollution equipped with low-cost gas sensors to be used to supplement regulatory agency monitoring for exposure assessment within a large epidemiological study. This paper describes the development of a series of hourly and daily field calibration models for Alphasense sensors for carbon monoxide (CO; CO-B4), nitric oxide (NO; NO-B4), nitrogen dioxide (NO2; NO2-B43F), and oxidizing gases (OX-B431)—which refers to ozone (O3) and NO2. The monitor network was deployed in the Puget Sound region of Washington, USA, from May 2017 to March 2019. Monitors were rotated throughout the region, including at two Puget Sound Clean Air Agency monitoring sites for calibration purposes, and over 100 residences, including the homes of epidemiological study participants, with the goal of improving long-term pollutant exposure predictions at participant locations. Calibration models improved when accounting for individual sensor performance, ambient temperature and humidity, and concentrations of co-pollutants as measured by other low-cost sensors in the monitors. Predictions from the final daily models for CO and NO performed the best considering agreement with regulatory monitors in cross-validated root-mean-square error (RMSE) and R2 measures (CO: RMSE = 18 ppb, R2 = 0.97; NO: RMSE = 2 ppb, R2 = 0.97). Performance measures for NO2 and O3 were somewhat lower (NO2: RMSE = 3 ppb, R2 = 0.79; O3: RMSE = 4 ppb, R2 = 0.81). These high levels of calibration performance add confidence that low-cost sensor measurements collected at the homes of epidemiological study participants can be integrated into spatiotemporal models of pollutant concentrations, improving exposure assessment for epidemiological inference.


2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Dingwang Huang ◽  
Lintao Li ◽  
Kang Wang ◽  
Yan Li ◽  
Kuang Feng ◽  
...  

AbstractA highly efficient, low-cost and environmentally friendly photocathode with long-term stability is the goal of practical solar hydrogen evolution applications. Here, we found that the Cu3BiS3 film-based photocathode meets the abovementioned requirements. The Cu3BiS3-based photocathode presents a remarkable onset potential over 0.9 VRHE with excellent photoelectrochemical current densities (~7 mA/cm2 under 0 VRHE) and appreciable 10-hour long-term stability in neutral water solutions. This high onset potential of the Cu3BiS3-based photocathode directly results in a good unbiased operating photocurrent of ~1.6 mA/cm2 assisted by the BiVO4 photoanode. A tandem device of Cu3BiS3-BiVO4 with an unbiased solar-to-hydrogen conversion efficiency of 2.04% is presented. This tandem device also presents high stability over 20 hours. Ultimately, a 5 × 5 cm2 large Cu3BiS3-BiVO4 tandem device module is fabricated for standalone overall solar water splitting with a long-term stability of 60 hours.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
J. A. van Ling ◽  
G. M. J. Bökkerink ◽  
I. de Blaauw ◽  
S. M. B. I. Botden

Abstract Background An Anorectal Malformation (ARM) is a rare congenital malformation, which requires proper correction to ensure the best long-term prognosis. These procedures are relatively infrequent and complex, in which a structured approach is important. Therefore, training on an affordable model could be beneficial. Methods A low-cost ARM model was developed. The base was reusable and the perineal body disposable. Both expert pediatric surgeons (Experts) and residents/fellows (Target group) were recruited for this study. After testing the model, they completed a questionnaire regarding the realism and didactic value of the model, using a 5-point Likert scale. Results Forty-four participants were recruited (Target group n = 20, Experts n = 24). The model has high mean scores of 3.8–4.4 for the total group and even higher on several aspects by the Target group. The experts regarded the haptics and manipulation of the fistula less realistic than the Target group (3.7 versus 4.3, p = 0.021 and 4.2 versus 4.6, p = 0.047). It was considered to be a very good training tool (mean 4.3), without significant differences between the groups. Conclusions These results show general consensus that this model is a potent training tool for the component steps of the repair of an ARM with recto-perineal fistula by sagittal approach.


Sign in / Sign up

Export Citation Format

Share Document