scholarly journals Numerical Simulated Concept and Mechanical Proof of Concept for a Transmission OCT (tOCT)

Author(s):  
Andreas Drauschke ◽  
Katharina Dettelbacher ◽  
Michaela Kienberger ◽  
Sarah Nagl ◽  
Christian Milz
2018 ◽  
Author(s):  
Travis L. Massey ◽  
Leane S. Kuo ◽  
Jiang Lan Fan ◽  
Michel M. Maharbiz

AbstractGlial encapsulation of chronically implanted neural probes inhibits recording and stimulation, and this signal loss is a significant factor limiting the clinical viability of most neural implant topologies for decades-long implantation. We demonstrate a mechanical proof of concept for silicon shank-style neural probes intended to minimize gliosis near the recording sites. Compliant whiskers on the edges of the probe fold inward to minimize tissue damage during insertion. Once implanted to the target depth and retracted slightly, these whiskers splay outward. The splayed tips, on which recording sites could be patterned, extend beyond the typical 50-100 micron radius of a glial scar. The whiskers are micron-scale to minimize or avoid glial scarring. Electrically inactive devices with whiskers of varying widths and curvature were designed and monolithically fabricated from a five-micron silicon-on-insulator (SOI) wafer, and their mechanical functionality was demonstrated in a 0.6% agar brain phantom. Deflection was plotted versus deflection speed, and those that were most compliant actuated successfully. This probe requires no preparation for use beyond what is typical for a shank-style silicon probe.


Author(s):  
A. G. Jackson ◽  
M. Rowe

Diffraction intensities from intermetallic compounds are, in the kinematic approximation, proportional to the scattering amplitude from the element doing the scattering. More detailed calculations have shown that site symmetry and occupation by various atom species also affects the intensity in a diffracted beam. [1] Hence, by measuring the intensities of beams, or their ratios, the occupancy can be estimated. Measurement of the intensity values also allows structure calculations to be made to determine the spatial distribution of the potentials doing the scattering. Thermal effects are also present as a background contribution. Inelastic effects such as loss or absorption/excitation complicate the intensity behavior, and dynamical theory is required to estimate the intensity value.The dynamic range of currents in diffracted beams can be 104or 105:1. Hence, detection of such information requires a means for collecting the intensity over a signal-to-noise range beyond that obtainable with a single film plate, which has a S/N of about 103:1. Although such a collection system is not available currently, a simple system consisting of instrumentation on an existing STEM can be used as a proof of concept which has a S/N of about 255:1, limited by the 8 bit pixel attributes used in the electronics. Use of 24 bit pixel attributes would easily allowthe desired noise range to be attained in the processing instrumentation. The S/N of the scintillator used by the photoelectron sensor is about 106 to 1, well beyond the S/N goal. The trade-off that must be made is the time for acquiring the signal, since the pattern can be obtained in seconds using film plates, compared to 10 to 20 minutes for a pattern to be acquired using the digital scan. Parallel acquisition would, of course, speed up this process immensely.


2002 ◽  
Author(s):  
Sheri Yvonne Nottestad Boyd ◽  
Linda L. Huffer ◽  
Terry D. Bauch ◽  
James L. Furgerson

2020 ◽  
Vol 92 (1) ◽  
pp. 10906
Author(s):  
Jeroen Schoenmaker ◽  
Pâmella Gonçalves Martins ◽  
Guilherme Corsi Miranda da Silva ◽  
Julio Carlos Teixeira

Organic Rankine Cycle (ORC) systems are increasingly gaining relevance in the renewable and sustainable energy scenario. Recently our research group published a manuscript identifying a new type of thermodynamic cycle entitled Buoyancy Organic Rankine Cycle (BORC) [J. Schoenmaker, J.F.Q. Rey, K.R. Pirota, Renew. Energy 36, 999 (2011)]. In this work we present two main contributions. First, we propose a refined thermodynamic model for BORC systems accounting for the specific heat of the working fluid. Considering the refined model, the efficiencies for Pentane and Dichloromethane at temperatures up to 100 °C were estimated to be 17.2%. Second, we show a proof of concept BORC system using a 3 m tall, 0.062 m diameter polycarbonate tube as a column-fluid reservoir. We used water as a column fluid. The thermal stability and uniformity throughout the tube has been carefully simulated and verified experimentally. After the thermal parameters of the water column have been fully characterized, we developed a test body to allow an adequate assessment of the BORC-system's efficiency. We obtained 0.84% efficiency for 43.8 °C working temperature. This corresponds to 35% of the Carnot efficiency calculated for the same temperature difference. Limitations of the model and the apparatus are put into perspective, pointing directions for further developments of BORC systems.


2012 ◽  
Vol 25 (01) ◽  
Author(s):  
A Klein ◽  
G Shafirstein ◽  
E Kohl ◽  
W Bäumler ◽  
M Landthaler ◽  
...  

Author(s):  
FV Güttler ◽  
K Winterwerber ◽  
C Gross ◽  
A Heinrich ◽  
M de Bucourt ◽  
...  
Keyword(s):  

2018 ◽  
Vol 09 (02) ◽  
pp. 65-66
Author(s):  
Alexander Kretzschmar

Zirkulierende Tumorzellen (Circulating Tumor Cells; CTC) sind Prädiktoren von Spät-rezidiven bei Frauen mit einem Hormonrezeptor-positiven (HR-positiv), HER2-negativen frühen Mammakarzinom. Dies ergab eine Proof-of-Concept-Studie, die von Dr. Joseph Sparano, New York, auf dem SABCS 2017 vorgestellt wurde. Spätrezidive machen etwa die Hälfte aller Östrogenrezeptor-positiven Rezidive aus. Genexpressionstests können zwar das Risiko eines Rezidivs insgesamt quantifizieren. Sparanos Arbeitsgruppe glaubt aber, dass CTC bessere Biomarker für Spätrezidive sind.


Sign in / Sign up

Export Citation Format

Share Document