scholarly journals Advanced Car Driving Assistant System: A Deep Non-local Pipeline Combined with 1D Dilated CNN for Safety Driving

Author(s):  
Francesco Rundo ◽  
Roberto Leotta ◽  
Francesca Trenta ◽  
Giovanni Bellitto ◽  
Federica Salanitri ◽  
...  
Keyword(s):  
System A ◽  
2014 ◽  
Vol 25 (3) ◽  
pp. 307-327 ◽  
Author(s):  
JILU WANG ◽  
WEIWEI SUN

The paper is concerned with heat and sweat transport in porous textile media with a non-local thermal radiation and phase change. The model, based on a combination of these classical heat transfer mechanisms (convection, conduction and radiation), is governed by a nonlinear, degenerate and strongly coupled parabolic system. The thermal radiative flow is described by a radiation transport equation and characterized by the thermal absorptivity and emissivity of fibre. A conservative boundary condition is introduced to describe the radiative heat flux interacting with environment. With the conservative boundary condition, we prove the global existence of positive/non-negative weak solutions of a nonlinear parabolic system. A typical clothing assembly with a polyester batting material sandwiched in two laminated covers is investigated numerically. Numerical results show that the contribution of radiative heat transfer is comparable with that of conduction/convection in the sweating system.


1996 ◽  
Vol 06 (03) ◽  
pp. 415-426 ◽  
Author(s):  
Y. LE GUYADEC ◽  
B. VIROT

We define a proof system à la Hoare for a common kernel of existing data-parallel languages. It includes conditioning constructs and non-local control transfers such as data-parallel break and continue. Assertions are usual predicates and manipulations of the extent of parallelism are translated into explicit assignments. Therefore, proofs reuse the classical assertional setting of sequential Hoare Logic.


Author(s):  
R. C. Moretz ◽  
G. G. Hausner ◽  
D. F. Parsons

Electron microscopy and diffraction of biological materials in the hydrated state requires the construction of a chamber in which the water vapor pressure can be maintained at saturation for a given specimen temperature, while minimally affecting the normal vacuum of the remainder of the microscope column. Initial studies with chambers closed by thin membrane windows showed that at the film thicknesses required for electron diffraction at 100 KV the window failure rate was too high to give a reliable system. A single stage, differentially pumped specimen hydration chamber was constructed, consisting of two apertures (70-100μ), which eliminated the necessity of thin membrane windows. This system was used to obtain electron diffraction and electron microscopy of water droplets and thin water films. However, a period of dehydration occurred during initial pumping of the microscope column. Although rehydration occurred within five minutes, biological materials were irreversibly damaged. Another limitation of this system was that the specimen grid was clamped between the apertures, thus limiting the yield of view to the aperture opening.


Author(s):  
Zhifeng Shao

Recently, low voltage (≤5kV) scanning electron microscopes have become popular because of their unprecedented advantages, such as minimized charging effects and smaller specimen damage, etc. Perhaps the most important advantage of LVSEM is that they may be able to provide ultrahigh resolution since the interaction volume decreases when electron energy is reduced. It is obvious that no matter how low the operating voltage is, the resolution is always poorer than the probe radius. To achieve 10Å resolution at 5kV (including non-local effects), we would require a probe radius of 5∽6 Å. At low voltages, we can no longer ignore the effects of chromatic aberration because of the increased ratio δV/V. The 3rd order spherical aberration is another major limiting factor. The optimized aperture should be calculated as


Author(s):  
Zhifeng Shao ◽  
A.V. Crewe

For scanning electron microscopes, it is plausible that by lowering the primary electron energy, one can decrease the volume of interaction and improve resolution. As shown by Crewe /1/, at V0 =5kV a 10Å resolution (including non-local effects) is possible. To achieve this, we would need a probe size about 5Å. However, at low voltages, the chromatic aberration becomes the major concern even for field emission sources. In this case, δV/V = 0.1 V/5kV = 2x10-5. As a rough estimate, it has been shown that /2/ the chromatic aberration δC should be less than ⅓ of δ0 the probe size determined by diffraction and spherical aberration in order to neglect its effect. But this did not take into account the distribution of electron energy. We will show that by using a wave optical treatment, the tolerance on the chromatic aberration is much larger than we expected.


Author(s):  
V. Castano ◽  
W. Krakow

In non-UHV microscope environments atomic surface structure has been observed for flat-on for various orientations of Au thin films and edge-on for columns of atoms in small particles. The problem of oxidation of surfaces has only recently been reported from the point of view of high resolution microscopy revealing surface reconstructions for the Ag2O system. A natural extension of these initial oxidation studies is to explore other materials areas which are technologically more significant such as that of Cu2O, which will now be described.


Author(s):  
Yimei Zhu ◽  
Masaki Suenaga ◽  
R. L. Sabatini ◽  
Youwen Xu

The (110) twin structure of YBa2Cu3O7 superconductor oxide, which is formed to reduce the strain energy of the tetragonal to orthorhombic phase transformation by alternating the a-b crystallographic axis across the boundary, was extensively investigated. Up to now the structure of the twin boundary still remained unclear. In order to gain insight into the nature of the twin boundary in Y-Ba-Cu-O system, a study using electron diffraction techniques including optical and computed diffractograms, as well as high resolution structure imaging techniques with corresponding computer simulation and processing was initiated.Bulk samples of Y-Ba-Cu-O oxide were prepared as described elsewhere. TEM specimens were produced by crushing bulk samples into a fine powder, dispersing the powder in acetone, and suspending the fine particles on a holey carbon grid. The electron microscopy during this study was performed on both a JEOL 2000EX and 2000FX electron microscopes operated at 200 kV.


1976 ◽  
Vol 7 (4) ◽  
pp. 207-219 ◽  
Author(s):  
Constance P. DesRoches

A statistical review provides analysis of four years of speech therapy services of a suburban school system which can be used for comparison with other school system programs. Included are data on the percentages of the school population enrolled in therapy, the categories of disabilities and the number of children in each category, the sex and grade-level distribution of those in therapy, and shifts in case-load selection. Factors affecting changes in case-load profiles are identified and discussed.


Sign in / Sign up

Export Citation Format

Share Document