Bond strength of orthodontic adhesives to dry and saliva-moistened enamel – a comparative in vitro study

2019 ◽  
Vol 2 (96) ◽  
pp. 79-84
Author(s):  
T. Stefański ◽  
A. Kloc-Ptaszna ◽  
L. Postek-Stefańska

salivamoistened enamel. Design/methodology/approach: One hundred twenty stainless steel brackets were bonded to human mandibular third molars with six materials: Enlight LC® (Ormco Corp), Grengloo® (Ormco Corp), Light Bond® (Reliance Orthodontic Products), Charisma® (Heraeus Kulzer), SmartBond® (Gestenco), and Transbond XT® with MIP® primer (3M Unitek). One half of the specimens in each group (n=10) was bonded to dry enamel, while the other half to saliva-moistened enamel. Bond strength testing was performed with a wire loop loading technique after 30-min incubation in artificial saliva. Failure mode was evaluated using adhesive remaining index (ARI). Findings: No significant differences in bond strength to dry enamel were noted for all composite materials (p>0.05). SmartBond exhibited significantly greater bond strength to moistened enamel (7.10 ± 1.47 MPa) and comparable with other composite materials to dry enamel. Composite materials demonstrated significantly reduced bond strength to saliva-moistened enamel (p<0.001), except for Transbond MIP, whose bond strength was not significantly decreased by saliva contamination (p=0.089). There was not statistically significant difference between bond strength of SmartBond and Transbond to saliva contaminated enamel. A higher incidence of cohesive failures was noted for all materials. Research limitations/implications: Composite light-cured materials provide adequate bond strength to dry enamel. Cyanoacrylate adhesive provides sufficient bond strength only under moist conditions. Transbond XT+MIP has sufficient bond strength to either dry or saliva-moistened enamel. Practical implications: The study evaluated the bonding strength of orthodontic brackets, which is a critical parameter in orthodontics, especially in situations that do not allow for proper isolation from saliva, such as bonding to impacted teeth following surgical exposure. Originality/value: Bond strengths evaluated with loop loading technique in different study environments would help the orthodontist to choose the most effective adhesive for the specific clinical situation.

2008 ◽  
Vol 02 (02) ◽  
pp. 086-090 ◽  
Author(s):  
Hale Ară ◽  
Nazmiye Dönmez ◽  
Sema Belli

ABSTRACTObjectives: The purpose of this in vitro study was to evaluate the effect of artificial saliva contamination on microtensile bond strength to pulp chamber dentin.Methods: Clearfil SE Bond (SEB) (Kuraray, JAPAN) adhesive system and Clearfil Photo Posterior (CPP) (Kuraray, JAPAN) composite resin were used. Twenty extracted caries-free human molar teeth were randomly distributed into four groups. Apart from a control group without contamination (Group 1), primed dentin surfaces were contaminated with artificial saliva (10 s), rinsed, dried, reprimed and bonded (Group 2), coated with adhesive, contaminated with artificial saliva, rinsed, dried, bonding procedures were repeated (Group 3), coated with adhesive, light cured, contaminated with saliva, rinsed, dried, treated with SE primer (SEP) and SEB (Group 4).After 24 hrs, the teeth were prepared for microtensile bond testing and tensile bond strength was measured (1mm/min). The data was calculated as MPa and analyzed using one-way ANOVA and Duncan test (P<.05).Results: The results indicated that Group 2 showed lowest bond strength when compared to the others (P<.05). No statistically significant difference was found between Groups 3 and 4 (P>.05).Conclusions: It was concluded that contamination during priming procedure has a negative effect on bond strength (P<.05). Although contamination of the uncured adhesive was not critical in this study (P>.05) any kind of contamination of the bonding area should, in principle, be avoided. (Eur J Dent 2008;2:86-90)


2021 ◽  
Vol 11 (9) ◽  
pp. 3971
Author(s):  
Vergano Edoardo Alberto ◽  
Baldi Andrea ◽  
Comba Allegra ◽  
Italia Edoardo ◽  
Ferrero Giorgio ◽  
...  

Background: To evaluate different adhesive luting procedures on coronal dentin bond-strength of Cerasmart CAD-CAM blocks with μTBS test. Methods: 36 molar crowns were flattened in order to expose sound dentin and a standardized smear layer was created with 600 grit paper. Specimens were divided into six groups according to the luting cement employed (n = 12 each): G1: Panavia V5 (Kuraray, Japan); G2: Bifix QM (Voco, Germany); G3: Estecem (Tokuyama, Japan). CAD-CAM blocks (Cerasmart, GC), shade A2LT, size 14, were sectioned with a diamond saw to obtain 4 mm high specimens, which were then luted on the coronal dentin, following the manufacturer instructions. Specimens were serially sectioned to obtain 1 mm thick beams in accordance with the μTBS test technique. Half of the beams were stressed to failure after 24 h (t = 0), while the other half were stored in artificial saliva for 12 months, at 37 °C, for ageing before stressing to failure (t = 12). Results: two-way ANOVA test showed significant difference for the factor “luting cement” (p = 0.0002), while the factor “time of storage” (p = 0.0991) had no significant effect on µTBS. Conclusions: PanaviaV5 seems to have better µTBS values at T0 than QM and ES and 1 year aging doesn’t seem to affect the bonding strength of tested systems.


2019 ◽  
Vol 13 (4) ◽  
pp. 305-310
Author(s):  
Mina Biria ◽  
Sajedeh Namaei Ghasemi ◽  
Seyedeh Mahsa Sheikh-Al-Eslamian ◽  
Narges Panahandeh

Background. This in vitro study aimed to evaluate the microshear bond strength (μSBS), microhardness and morphological characteristics of primary enamel after treating with sodium fluoride (NaF) and acidulated phosphate fluoride (APF). Methods. Forty-eight primary canines were cut into mesial and distal sections and assigned to five groups randomly: group 1 (immersed in saliva as a control), group 2 (treated with NAF and immersed in saliva for 30 minutes), group 3 (treated with APF and immersed in saliva for 30 minutes), group 4 (treated with NAF and immersed in saliva for 10 days), and group 5 (treated with APF and immersed in saliva for 10 days). Composite resin (Filtek Z250) was bonded on the specimens (n=15) for measuring the μSBS. After storage in 37°C artificial saliva for 24 hours, µSBS and Vickers hardness tests (10 readings) were performed. The data were analyzed using one-way ANOVA and Kolmogorov-Smirnov, Levene’s and Tukey HSD tests (P<0.05). Morphological analysis of enamel and modes of failure were carried out under a scanning electron microscope (SEM) on two remaining specimens. Results. Significant differences in μSBS were only noted between groups 2 and 4 (P=0.024). Group 3 showed a significant decrease in hardness after storage in artificial saliva (P<0.001), with a significantly lower hardness than the other groups (P<0.001). The SEM observations showed irregular particles in groups 3 and 5; uniform, smooth and thin coats were seen in groups 2 and 4. Conclusion. Fluoride therapy with NaF and APF gels prior to restorative treatments had no adverse effects on the microshear bond strength.


2016 ◽  
Vol 17 (12) ◽  
pp. 997-1002 ◽  
Author(s):  
Fahad I Alkhudhairy ◽  
Zeeshan H Ahmad

ABSTRACT Introduction Various bulk-fill materials depending on their composition, viscosity, and flow ability have different physical and mechanical properties. The aim of this in vitro study was to determine and compare the shear bond strength and microleakage properties of activa restorative with other bulk-fill restorative materials surefil (SDR), Biodentine, ever X posterior. Materials and methods Forty permanent premolars were selected for shear bond strength, and 20 permanent premolars were selected with class II cavities on mesial and distal side for microleakage. Universal testing device was used to assess the shear bond strength. Microleakage was checked using dye penetration method under a stereomicroscope. Mean and standard deviation values were calculated from the recorded values. Intergroup comparison was done by one-way analysis of variance (ANOVA) followed by pairwise comparison using Tukey honestly significant difference (HSD) post hoc test. Results The mean shear bond strength was highest for SDR surefil followed by Ever X posterior, Bioactive restorative, and Biodentine respectively. In this study, SDR (surefil) showed better shear bond strength and better microleakage properties compared with the other test materials (F = 186.7157, p < 0.05). Conclusion The result of this study showed that flowable and fiber-reinforced composites have better shear bond strength and microleakage properties. Clinical significance Flowable bulk-fill composite resins can be used as dentin substitutes because of its superior properties. How to cite this article Alkhudhairy FI, Ahmad ZH. Comparison of Shear Bond Strength and Microleakage of Various Bulk-fill Bioactive Dentin substitutes: An in vitro study. J Contemp Dent Pract 2016;17(12):997-1002.


2017 ◽  
Vol 11 (01) ◽  
pp. 058-063 ◽  
Author(s):  
Vini Rajeev ◽  
Rajeev Arunachalam ◽  
Sanjna Nayar ◽  
P. R. Arunima ◽  
Sivadas Ganapathy ◽  
...  

ABSTRACT Objective: This in vitro study was designed to assess shear bond strength (SBS) of ormocer flowable (OF) resin as a luting agent, ormocer as an indirect veneer material with portrayal of modes of failures using scanning electron microscope (SEM). Materials and Methods: Sixty maxillary central incisors were divided into Group I, II, and III with 20 samples each based on luting cement used. They were OF, self-adhesive (SA) cement, and total etch (TE) cement. These groups were subdivided into “a” and “b” of ten each based on the type of veneering materials used. Veneer discs were fabricated using Ormocer restorative (O) and pressable ceramic (C). Specimens were thermocycled and loaded under universal testing machine for SBS. The statistical analysis was done using one-way ANOVA post hoc Tukey honest significant difference method. Results: A significant difference was observed between the Groups I and II (P < 0.05). The highest mean bond strength when using ormocer veneer was obtained with the Group Ia (19.11 ± 1.92 Mpa) and lowest by Group IIa (8.1 ± 1.04 Mpa), whereas the highest mean bond strength while using ceramic veneer was of similar range for Group Ib (18.04 ± 4.08 Mpa) and Group IIIb (18.07 ± 1.40 Mpa). SEM analysis revealed OF and TE presented mixed type of failure when compared with SA where failure mode was totally adhesive. Conclusion: OF was found equally efficient like TE. Bond strength of ormocer as a veneer was not inferior to ceramic making it one of the promising additions in the field of dentistry.


2018 ◽  
Vol 6 (02/03) ◽  
pp. 106-111
Author(s):  
Ramandeep Kaur ◽  
Manjit Kumar ◽  
Shailesh Jain ◽  
Neha Jindal

Abstract Statement of Problem The adhesion of impression material to impression tray is very important. Tray adhesive plays a major role in making accurate impression. Although manufactures recommend the use of particular tray adhesives, comparison of their affective adhesiveness has not been reported. The effect of use of tray adhesives on dimensional accuracy of dies has not been established. Purpose The aim of this study was to compare the dimensional accuracy of dies using different tray adhesives at different time intervals. Materials and Methods First part of study comprised 120 samples in six groups with 20 samples in each group. First group comprised samples with no tray adhesive, and in other five groups, different types of tray adhesives were applied. The dies obtained were evaluated for upper diameter, lower diameter, and occlusogingival height. In the second part, there were a total of 125 samples in five groups with 25 samples in each group. Five different types of tray adhesive were applied for five different time intervals 5, 10, 15, 20, and 25 minutes, respectively. The specimens were tested in tensile mode for its debonding force at a crosshead speed of 5 mm/min, until separation failure occurred. Results Significant difference was seen for upper and lower diameters when compared with the group without any tray adhesive. The maximum bond strength was found in the group in which tray adhesive was applied for 20 minutes.


2020 ◽  
Vol 24 (1) ◽  
pp. 21-28
Author(s):  
Ediz Kale ◽  
Ayça Deniz İzgi ◽  
Remzi Niğiz

SummaryBackground/Aim: The purpose of this in-vitro study was to compare the resin-bonded fixed partial dentures (RBFPD) fabricated using two different structural designs and two different antibacterial adhesive lutting protocols in regard to their resistance to debonding.Material and Methods: Forty samples for a model with single missing molar were divided into 4 groups (M1, M2, C1, C2) (n=10). M1 and M2 were prepared in accordance with modified inlay slot-cavity retained RBFPD design; C1 and C2 were prepared according to conventional inlay slot-cavity retained RBFPD design. M1 and C1 cavities were treated with 2% chlorhexidine-based (CHX) cavity disinfectant and 10-methacryloyloxydecyl dihydrogen phosphate (MDP) containing adhesive system; M2 and C2 cavities were treated with MDP and 12-methacryloyloxydodecylpyridinium bromide (MDPB) containing adhesive system featuring antibacterial cavity cleansing effect. The RBFPDs were made of base-metal alloy and their fit surfaces sandblasted with aluminium oxide (Al2O3). Adhesive resin cement was used for cementation, and the RBFPD retainers were interlocked into their corresponding inlay cavities using composite resin. After 1 week being immersed in aqueous environment, the RBFPDs were subjected to tensile loading at a crosshead speed of 1 mm/min until failure. One way ANOVA and Tukey HSD tests were used for statistical evaluation (α=0.05). Mode of failure and tooth damage was also noted.Results: Mean tensile bond strength values were 356 N for M1, 305 N for M2, 467 N for C1, and 455 N for C2. Tensile strength values of C1 and C2 were significantly higher than those of M1 and M2 (p<0.05). The mode of failure was mostly adhesive in character at the metal-cement interface in all groups. Tooth fracture was observed nearly in all specimens. No significant difference was detected between the antibacterial adhesive lutting protocols (p>0.05).Conclusions: The RBFPDs with the conventional design were found to be more retentive than those with the modified design. Using an adhesive system featuring antibacterial properties with no need of separate antibacterial agent application during bonding may be favourable.


2013 ◽  
Vol 70 (3) ◽  
pp. 279-283
Author(s):  
Mirjana Apostolovic ◽  
Biljana Kalicanin ◽  
Marija Igic ◽  
Olivera Trickovic-Janjic ◽  
Dusan Surdilovic ◽  
...  

Bacground/Aim. Glass ionomer cements (GIC) belong to the group of polycarboxyl cements, and one of the principal characteristics of these materials is their anticariogenic potential of fluorine release into saliva and enamel-dentin substance. The aim of this study was to examine the content of released fluorine from GIC restorations (Fuji IX, GC, Japan) of young permanent teeth in the medium of artificial saliva and similar releases in the same medium by the restorations of these teeth treated with a low concentration fluoride solution. Methods. We examined 12 premolars exctracted from orthodontic reasons. The GIC restored teeth were divided into the group treated daily with low concentration fluoride solution (334 ppm) and the control, not treated group. The samples of artificial saliva were analyzed for fluorine ion content using an ion selective electrode. Results. Our comparative analysis of the mean values using the Student?s t-test demonstrated a statistically significant difference in fluorine ion concentration in artificial saliva of fluoridated and non-fluoridated teeth with GIC fillings after 14 and 21 days (p < 0.05), while the difference detected after 7 days was with no statistical significance. Conclusion. The results of this in vitro study indicated that low-concentration fluoride solutions could serve to refluoridate GIC fillings and contribute to an increased fluorine content in saliva. The process of refluoridation of GIC fillings should be advised 2-3 weeks after the restoration, since the release of fluorine from GIC fillings diminishes in time.


2019 ◽  
Vol 13 (1) ◽  
pp. 255-260
Author(s):  
Francisco Molina ◽  
Karina Maria Salvatore Freitas ◽  
Maria Cristina Rockenbach Binz Ordóñez ◽  
Emerson Flamarion Cruz ◽  
Rafael Pinelli Henriques ◽  
...  

Objective: The objective of this study was to evaluate in vitro the shear bond strength of two types of MIM (Metal Injection Molding) technology brackets, one with conventional mesh base and the other with rail-shaped mesh base. Materials and Methods: Forty human premolars received the bonding of 2 types of brackets: Group 1- 20 Synergy metal brackets (Rocky Mountain) with conventional mesh base and Group 2-20 H4 brackets (OrthoClassic) with rail-shaped mesh base. Both brackets were bonded with Resilience photopolymerizable resin (OrthoTechnology). The specimens were coupled to a Tinius Olsen universal test machine where the shear test was performed using a chisel. In addition, the amount of remaining resin in tooth crown with the ImageJ program was evaluated and the Adhesive Remnant Index (ARI). Intergroup comparison was performed by the independent t test and Chi-square test. Results: There was no statistically significant difference between the groups for any of the measures evaluated indicating that the mesh type of the brackets’ base with MIM technology did not influence the shear bond strength of the brackets (shear bond strength, p=0.191; maximum load registered, p=0.244). There was also no difference between the percentage (p=0.602) and area of remaining resin in the teeth (p=0.805) and IRA (p=0.625) between the Synergy and H4 groups. Conclusion: Shear bond strength was similar in the two types of brackets with MIM technology evaluated. In addition, the remaining resin in the dental enamel of two types of brackets were also similar.


2021 ◽  
Vol 58 (1) ◽  
pp. eUJ3657
Author(s):  
Germano Brandão ◽  
◽  
Liliana Ávila Maltagliati ◽  
Ana Carla Raphaelli Nahás-Scocate ◽  
Murilo Matias ◽  
...  

The objective of this in vitro study was to assess and compare the shear bond strength of conventional and modified orthodontic tubes bonded to the surface of dry and saliva-contaminated enamel. The sample consisted of 40 human teeth, which were randomly divided into four groups according to attachment base and presence or absence of saliva contamination as follows: Group CB, conventional orthodontic tubes without salivary contamination; Group CB-S, conventional orthodontic tubes with salivary contamination; Groups BM, orthodontic tubes modified by welding a metal mesh to their base without salivary contamination; and Group BM-S, modified orthodontic tubes with salivary contamination. Shear bond strength test was performed in a universal testing machine and analysis of the adhesive remnant index (ARI) by optical microscopy. Two-way ANOVA was used, followed by Tukey’s test at a statistical significance level of 5%. The ARI results were analysed descriptively. There was statistically significant difference between the groups regarding the shear bond strength values, with conventional tubes presenting significantly higher values (P < 0.05). In addition, the presence of salivary contamination interfered negatively with the behaviour of conventional tubes only (P < 0.05). Shear bond strength was not improved by increasing the area of the orthodontic tubes. Moreover, salivary contamination influenced negatively the SBS values, but only when conventional tubes were used.


Sign in / Sign up

Export Citation Format

Share Document