EVALUATION OF MG-25 FUSE QUALITY AT LIFE CYCLE AND IDENTIFICATION OF OCCURRING FAULTS
The paper presents an analysis of faults of MG-25 fuse which affect the efficiency of this article in the life cycle and were detected at testing its technical status. The analysis was made on the grounds of test results [1] received for production lots of MG-25 fuses from years 1970-2000. The quantitative contribution of particular faults affecting the quality of this article was illustrated by Pareto-Lorenz method.