scholarly journals Trabecular bone patterning in the hominoid distal femur

PeerJ ◽  
2018 ◽  
Vol 6 ◽  
pp. e5156 ◽  
Author(s):  
Leoni Georgiou ◽  
Tracy L. Kivell ◽  
Dieter H. Pahr ◽  
Matthew M. Skinner

BackgroundIn addition to external bone shape and cortical bone thickness and distribution, the distribution and orientation of internal trabecular bone across individuals and species has yielded important functional information on how bone adapts in response to load. In particular, trabecular bone analysis has played a key role in studies of human and nonhuman primate locomotion and has shown that species with different locomotor repertoires display distinct trabecular architecture in various regions of the skeleton. In this study, we analyse trabecular structure throughout the distal femur of extant hominoids and test for differences due to locomotor loading regime.MethodsMicro-computed tomography scans ofHomo sapiens(n= 11),Pan troglodytes(n= 18),Gorilla gorilla(n= 14) andPongosp. (n= 7) were used to investigate trabecular structure throughout the distal epiphysis of the femur. We predicted that bone volume fraction (BV/TV) in the medial and lateral condyles inHomowould be distally concentrated and more anisotropic due to a habitual extended knee posture at the point of peak ground reaction force during bipedal locomotion, whereas great apes would show more posteriorly concentrated BV/TV and greater isotropy due to a flexed knee posture and more variable hindlimb use during locomotion.ResultsResults indicate some significant differences between taxa, with the most prominent being higher BV/TV in the posterosuperior region of the condyles inPanand higher BV/TV and anisotropy in the posteroinferior region inHomo. Furthermore, trabecular number, spacing and thickness differ significantly, mainly separatingGorillafrom the other apes.DiscussionThe trabecular architecture of the distal femur holds a functional signal linked to habitual behaviour; however, there was more similarity across taxa and greater intraspecific variability than expected. Specifically, there was a large degree of overlap in trabecular structure across the sample, andHomowas not as distinct as predicted. Nonetheless, this study offers a comparative sample of trabecular structure in the hominoid distal femur and can contribute to future studies of locomotion in extinct taxa.

2019 ◽  
Vol 48 (2) ◽  
pp. 595-605 ◽  
Author(s):  
S. S. Karhula ◽  
M. A. J. Finnilä ◽  
S. J. O. Rytky ◽  
D. M. Cooper ◽  
J. Thevenot ◽  
...  

Abstract The aim of this study was to quantify sub-resolution trabecular bone morphometrics, which are also related to osteoarthritis (OA), from clinical resolution cone beam computed tomography (CBCT). Samples (n = 53) were harvested from human tibiae (N = 4) and femora (N = 7). Grey-level co-occurrence matrix (GLCM) texture and histogram-based parameters were calculated from CBCT imaged trabecular bone data, and compared with the morphometric parameters quantified from micro-computed tomography. As a reference for OA severity, histological sections were subjected to OARSI histopathological grading. GLCM and histogram parameters were correlated to bone morphometrics and OARSI individually. Furthermore, a statistical model of combined GLCM/histogram parameters was generated to estimate the bone morphometrics. Several individual histogram and GLCM parameters had strong associations with various bone morphometrics (|r| > 0.7). The most prominent correlation was observed between the histogram mean and bone volume fraction (r = 0.907). The statistical model combining GLCM and histogram-parameters resulted in even better association with bone volume fraction determined from CBCT data (adjusted R2 change = 0.047). Histopathology showed mainly moderate associations with bone morphometrics (|r| > 0.4). In conclusion, we demonstrated that GLCM- and histogram-based parameters from CBCT imaged trabecular bone (ex vivo) are associated with sub-resolution morphometrics. Our results suggest that sub-resolution morphometrics can be estimated from clinical CBCT images, associations becoming even stronger when combining histogram and GLCM-based parameters.


Author(s):  
Xiaowei S. Liu ◽  
X. Henry Zhang ◽  
Paul Sajda ◽  
Punam K. Saha ◽  
Felix W. Wehrli ◽  
...  

Osteoporosis is an age-related disease characterized by low bone mass and architectural deterioration. Other than bone volume fraction (BV/TV), microarchitecture of trabecular bone, such as trabecular type (rods or plates), connectivity, and orientation of the trabecular network is also believed to be important in governing the mechanical properties of trabecular bone. A recent study [1] showed that the microarchitecture alone affects elastic moduli of trabecular bone and, further, that trabecular plates make a far greater contribution than rods. In human vertebral trabecular bone, the roles of transverse vs. vertical rods in conferring mechanical properties of trabecular bone have been debated [2, 3]. It has been suggested that the role of transverse trabecular rod is critical in determining elastic modulus of vertebral trabecular bone. However, without explicit classifications of trabecular type, or orientation assessment at an individual trabecula level, it is not possible yet to test this hypothesis in human trabecular bone samples despite the development of three-dimensional (3D) micro computed tomography (μCT) and μCT based finite element (FE) models of human trabecular bone. With the newly developed technique of complete volumetric decomposition and individual trabecula based orientation analyses [4], now it is possible to quantitatively examine the contributions of trabecular rods of various orientations in the elastic properties of vertebral trabecular bone.


2019 ◽  
Vol 31 (1-2) ◽  
pp. 43-51 ◽  
Author(s):  
A. Colombo ◽  
N. B. Stephens ◽  
Z. J. Tsegai ◽  
M. Bettuzzi ◽  
M. P. Morigi ◽  
...  

In modern day populations, children following a normal pattern of development acquire independent bipedal locomotion between the ages of 9 and 18 months. Variability in the timing of this psychomotor developmental milestone depends on various factors, including cultural influences. It is well known that trabecular bone adapts to changes in biomechanical loading and that this can be influenced by alternative locomotor modes, such as crawling, which may be adopted before the acquisition of bipedal locomotion. With the onset of crawling, increased loading of the distal metaphysis of the radius, a component of the wrist, may lead to changes in trabecular bone architecture. To test this hypothesis, eight distal metaphyses of the radius of nonpathological children aged 0 to 3 years from the Bologna collection of identified skeletons were μCT-scanned at a resolution of 10.7 μm. The microarchitectural parameters of the trabecular bone (trabecular bone volume fraction, trabecular thickness, trabecular spacing, and trabecular ellipsoid factor) were quantified for the entire metaphysis and 3D morphometric maps of the distribution of the bone volume fraction were generated. Analysis of these microarchitectural parameters and the 3D morphometric maps show changes in the trabecular bone structure between 6 and 15 months, the period during which both crawling and bipedalism are acquired. This preliminary study analyzed the trabecular structure of the growing radius in three dimensions for the first time, and suggests that ontogenetic changes in the trabecular structure of the radial metaphysis may be related to changes in the biomechanical loading of the wrist during early locomotor transitions, i.e. the onset of crawling. Moreover, microarchitectural analysis could supply important information on the developmental timing of locomotor transitions, which would facilitate interpretations of locomotor development in past populations.


2000 ◽  
Vol 164 (2) ◽  
pp. 239-245 ◽  
Author(s):  
T Yamashita ◽  
Y Nabeshima ◽  
M Noda

Inactivation mutation of the recently discovered klotho gene in mice causes a syndrome resembling aging. Manifestations include short life span, atherosclerosis, gonadal atropy, skin atropy, emphysema, ataxia and ectopic calcification. These mice also exhibit abnormally high bone density in the epiphyses of their tibiae based on X-ray and histological analyses. However, micro-structures of the trabecular bones in arbitrary two-dimensional planes or three-dimensional regions are difficult to analyze by these techniques. Therefore, we applied high resolution micro-computed tomography (microCT) to characterize the micro-structural abnormality in the trabecular bone in long bones as well as in vertebrae of four- to six-week-old klotho mutant mice. Two-dimensional microCT analyses in the mid-sagittal plane as well as three-dimensional microCT analyses indicated that the trabecular bone volume fraction measured in the proximal metaphyses of the tibiae was increased more than twofold in klotho mutant mice compared with the wild-type mice. Similarly, the trabecular bone area fraction in the mid-sagittal plane of the lumbar vertebral bodies was also increased by about 80% at the proximal and distal ends. No significant difference was observed with regard to the cortical thickness in the mid-shaft of femora between klotho mutant and wild-type mice. Three-dimensional microCT analyses also indicated that the trabecular number and thickness of the proximal metaphyses of the tibiae were increased by about 80% and 300% respectively in the klotho mutant mice, while trabecular separation was 60% less in klotho mutant mice compared with the wild-type mice. These quantitative microCT analyses indicate that the inactivation of klotho gene expression results in an increase in three-dimensional bone volume fraction, number and thickness of the trabecular bones in these mice.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Jingyan Fu ◽  
Matthew Goldsmith ◽  
Sequoia D. Crooks ◽  
Sean F. Condon ◽  
Martin Morris ◽  
...  

AbstractAnimals in space exploration studies serve both as a model for human physiology and as a means to understand the physiological effects of microgravity. To quantify the microgravity-induced changes to bone health in animals, we systematically searched Medline, Embase, Web of Science, BIOSIS, and NASA Technical reports. We selected 40 papers focusing on the bone health of 95 rats, 61 mice, and 9 rhesus monkeys from 22 space missions. The percentage difference from ground control in rodents was –24.1% [Confidence interval: −43.4, −4.9] for trabecular bone volume fraction and –5.9% [−8.0, −3.8] for the cortical area. In primates, trabecular bone volume fraction was lower by –25.2% [−35.6, −14.7] in spaceflight animals compared to GC. Bone formation indices in rodent trabecular and cortical bone were significantly lower in microgravity. In contrast, osteoclast numbers were not affected in rats and were variably affected in mice. Thus, microgravity induces bone deficits in rodents and primates likely through the suppression of bone formation.


2013 ◽  
Vol 135 (12) ◽  
Author(s):  
Arnav Sanyal ◽  
Tony M. Keaveny

The biaxial failure behavior of the human trabecular bone, which has potential relevance both for fall and gait loading conditions, is not well understood, particularly for low-density bone, which can display considerable mechanical anisotropy. Addressing this issue, we investigated the biaxial normal strength behavior and the underlying failure mechanisms for human trabecular bone displaying a wide range of bone volume fraction (0.06–0.34) and elastic anisotropy. Micro-computed tomography (CT)-based nonlinear finite element analysis was used to simulate biaxial failure in 15 specimens (5 mm cubes), spanning the complete biaxial normal stress failure space in the axial-transverse plane. The specimens, treated as approximately transversely isotropic, were loaded in the principal material orientation. We found that the biaxial stress yield surface was well characterized by the superposition of two ellipses—one each for yield failure in the longitudinal and transverse loading directions—and the size, shape, and orientation of which depended on bone volume fraction and elastic anisotropy. However, when normalized by the uniaxial tensile and compressive strengths in the longitudinal and transverse directions, all of which depended on bone volume fraction, microarchitecture, and mechanical anisotropy, the resulting normalized biaxial strength behavior was well described by a single pair of (longitudinal and transverse) ellipses, with little interspecimen variation. Taken together, these results indicate that the role of bone volume fraction, microarchitecture, and mechanical anisotropy is mostly accounted for in determining the uniaxial strength behavior and the effect of these parameters on the axial-transverse biaxial normal strength behavior per se is minor.


2006 ◽  
Vol 321-323 ◽  
pp. 1070-1073
Author(s):  
Ye Yeon Won ◽  
Myong Hyun Baek ◽  
Wen Quan Cui ◽  
Kwang Kyun Kim

This study investigates micro-structural and mechanical properties of trabecular bone in human femoral head with and without osteoporosis using a micro-CT and a finite element model. 15 cored trabecular bone specimens with 20 of diameter were obtained from femoral heads with osteoporosis resected for total hip arthroplasty, and 5 specimens were removed from femoral head of cadavers, which has no history of musculoskeletal diseases. A high-resolution micro-CT system was used to scan each specimen to obtain histomorphometry indexes. Based on the micro-images, a FE-model was created to determine mechanical property indexes. While the non-osteoporosis group had increases the trabecular thickness, the bone volume, the bone volume fraction, the degree of anisotropy and the trabecular number compared with those of osteoporotic group, the non-osteoporotic group showed decreases in trabecular separation and structure model index. Regarding the mechanical property indexes, the reaction force and the Young's modulus were lower in the osteoporotic group than in non-osteoporotic group. Our data shows salient deteriorations in trabecular micro-structural and mechanical properties in human femoral head with osteoporosis.


2005 ◽  
Vol 874 ◽  
Author(s):  
Richard Weinkamer ◽  
Markus A. Hartmann ◽  
Yves Brechet ◽  
Peter Fratzl

AbstractUsing a stochastic lattice model we have studied the architectural changes of trabecular bone occurring while the structure is remodeled. Our model considers the mechanical feedback loop, which control the remodeling process. A fast algorithm was employed to solve approximately the mechanical problem. A general feature of the model is that a networklike structure emerges, which further coarsens while the bone volume fraction remains unchanged. Decreasing the mechanical response of the system by either lowering the external load or the internal mechano-sensitivity leads not only to a reduction of the bone volume fraction, but results in topological changes of the trabecular bone architecture, where the loss of horizontal trabeculae is the most obvious effect.


2021 ◽  
Vol 8 (6) ◽  
pp. 201401
Author(s):  
A. A. Felder ◽  
S. Monzem ◽  
R. De Souza ◽  
B. Javaheri ◽  
D. Mills ◽  
...  

Changes in trabecular micro-architecture are key to our understanding of osteoporosis. Previous work focusing on structure model index (SMI) measurements have concluded that disease progression entails a shift from plates to rods in trabecular bone, but SMI is heavily biased by bone volume fraction. As an alternative to SMI, we proposed the ellipsoid factor (EF) as a continuous measure of local trabecular shape between plate-like and rod-like extremes. We investigated the relationship between EF distributions, SMI and bone volume fraction of the trabecular geometry in a murine model of disuse osteoporosis as well as from human vertebrae of differing bone volume fraction. We observed a moderate shift in EF median (at later disease stages in mouse tibia) and EF mode (in the vertebral samples with low bone volume fraction) towards a more rod-like geometry, but not in EF maximum and minimum. These results support the notion that the plate to rod transition does not coincide with the onset of bone loss and is considerably more moderate, when it does occur, than SMI suggests. A variety of local shapes not straightforward to categorize as rod or plate exist in all our trabecular bone samples.


Sign in / Sign up

Export Citation Format

Share Document