scholarly journals Study on Improvement of Thermal Environment by using Wind-driven Natural Ventilation on the Atrium

2012 ◽  
Vol 32 (1) ◽  
pp. 40-47 ◽  
Author(s):  
Ji-Woong Roh
2014 ◽  
Vol 1065-1069 ◽  
pp. 2137-2140
Author(s):  
Xiao Hu Yang ◽  
Yan Long ◽  
Ling Zhao Meng ◽  
Yu Hui Jin

In this paper, we used orthogonal experiment method and Computational Fluid Dynamics (CFD) technology to simulate the thermal environment of the iron and steel workshop. By comparing and analyzing the temperature distribution and air flow of workshops with different window structures, we obtained an optimization of natural ventilation design for industrial workshop. The research results can be used for the structure design or reformation of industrial workshops as reference.


2019 ◽  
Vol 111 ◽  
pp. 01085
Author(s):  
Hiroshi Muramatsu ◽  
Tatsuo Nobe

In this study, an office building in Japan that incorporates energy-saving features and environmental technologies was investigated. This office building features a green façade, natural ventilation, a concrete slab with no suspended ceilings, and thermo-active building systems. Two airconditioning systems were installed in this building—a ceiling radiation air-conditioning system and a whole floor-blow off air conditioning system. In addition, a natural ventilation system was installed. We surveyed the heat flux of the ceiling surface and indoor thermal environment of this building from 2015 through 2016. The ceiling using the heat storage amount of concrete maintains a constant temperature in the workplace during as well as after office hours. We also performed detailed measurements of the heat flux of the ceiling surface and indoor thermal environment in the summer of 2017. The results showed that the ceiling radiation air-conditioning system provided a stable thermal environment. Furthermore, we report that making use of the thermal behavior of the skeleton improved the operation of the ceiling radiation airconditioning system.


2011 ◽  
Vol 243-249 ◽  
pp. 6857-6861 ◽  
Author(s):  
Li Juan Wang ◽  
Jia Ping Liu ◽  
Yan Feng Liu ◽  
Ying Ying Wang ◽  
Jing Chen

Haikou is located in tropic climates in China. The outdoor environment in summer is too harsh to stay here. However, the traditional architecture, namely arcade, still survives in the severe climate. Its indoor and outdoor parameters of arcade are tested in field to research its thermal environments. The heat stress index is used to study the adaptability mechanism of arcade and local human to hot and humid environment. It proves that the metabolic rate and wind velocity are main and adjustable factors to reduce heat stress in such wretched weather. On the condition of metabolic rate below 60met and wind speed above 0.7m/s, the healthy adult can work normally in the arcade or on the corridor. So the human in tropic area should keep their metabolic rate and period staying out in the summer daytime as less as possible, and the architects should make full use of the local wind speed to organize natural ventilation.


2011 ◽  
Vol 20 (1) ◽  
pp. 101-111 ◽  
Author(s):  
Baizhan Li ◽  
Wei Yu ◽  
Meng Liu ◽  
Nan Li

Yangtze River Valley is situated within the Hot Summer and Cold Winter zone, and residents in this region of China would require HVAC system to alleviate thermal comfort conditions, although this is tempered by the Design Code (DBJ50-071-2007) for energy efficiency. A 1-year survey of about 200 residential homes was carried out in eight cities covering the breadth of the region. The acceptable temperature range for the residents in this area was 16.3—28.1°C and the thermal neutral temperature was found to be 27.6°C in summers and 17.5°C in winters. People in different area can vary in their adaptability and comfortableness. Therefore, there is a need to investigate the national comfort parameter introduced in the Code for Design of Heating and Ventilation and Air Conditioning (GB50019-2003). The results found that if air-conditioning system was set to 27.5°C instead of 26°C as required by GBJ19-87: Design Standard of Heating and Ventilation and Air Conditioning, a 16.5% saving of energy consumption could be achieved. The findings demonstrated the role of natural ventilation in the expansion of the thermal comfort zone for the residents, especially during the summer seasons. A climatic adaptability model has been established by this study to contribute to the passive climatic design strategies for a better economic and energy efficiency of buildings.


2011 ◽  
Vol 361-363 ◽  
pp. 1056-1060 ◽  
Author(s):  
Bao Lin ◽  
Xue Ting Wang ◽  
Xiao Hu

Because of the relatively narrow space and high density distribution of the passengers, the bus interior environment deteriorates in summer. Natural ventilating introduces a fresh natural freeze, provides the bus interior with appropriate distribution of air supply temperature and velocity field. Making good use of natural ventilation is an operating strategy ideal for improving passengers’ satisfaction, which is considered as an environmental friendly and cost effective approach. Based on CFD numerical simulation, with a whole-domain approach, this paper predicts air flow and thermal comfort in naturally ventilated bus. The outside and inside airflow is modelled simultaneously and within the same computational domain. The thermal environment in different parts of the bus interior is compared. Different vehicle velocities and conditions of windows are taken into account, analysis are made regarding to the effect of both of them on the interior thermal comfort. The result shows, air disturbance at the bus rear parts are intenser than the other parts with better thermal satisfaction; the quality of air flow in different parts makes the temperature difference in bus achieve as high as 3°C; the use of roof openings distributes the temperature more evenly.


2012 ◽  
Vol 512-515 ◽  
pp. 2882-2886
Author(s):  
Shi Jie Wu ◽  
Zeng Feng Yan

Natural ventilation is an important role to improve the residential building indoor thermal environment in summer. This paper use Energy Plus to simulate indoor thermal environment and use CFD to simulate indoor air flow for Xi’an residential building, analysis the influence that different ventilation mode for indoor thermal environment factors. Then with the simulated result of PMV-PPD value to estimate indoor thermal comfort. Proved night ventilation is necessary in residential building in Xi’an and effectiveness to improve indoor thermal comfort.


2020 ◽  
Vol 3 (1) ◽  
pp. p1
Author(s):  
Jad Hammoud ◽  
Elise Abi Rached

The increasing of energy demands has considerably increased the requirements for new and traditional buildings in different climate zones. Unprecedented heat waves have increased climate temperature, in particular, in moderate climate zones such as Lebanon. In Beirut, only the residential sector consumes 50% of total electricity consumption. HVAC (Heating, Ventilation and Air conditioning) systems are used to reach acceptable thermal comfort levels in the new residential buildings. In case of the traditional bourgeoisie houses in Beirut, there are no discussions about the use of HVAC systems to achieve the required thermal comfort level. Thus, to reach an acceptable thermal comfort level, these houses which already contain natural ventilation system shall adapt the modern thermal comfort requirements and thermal comfort strategies and technologies where their architectural features and existing materials condition the available solutions. In order to identify the best options within the possible intervention lines (envelopes, passive strategies, equipment, renewable energy systems), it is necessary to perceive the real performance of this type of houses. In this context, the article presents the results of the study of thermal performance and comfort in a three case studies located in Beirut. Detailed field data records collected are analyzed, with a view to identify the indoor thermal environment with respect to outdoor thermal environment in different seasons. Monitoring also included measurement of hygrothermal parameters and surveys of occupant thermal sensation.


2021 ◽  
Vol 881 (1) ◽  
pp. 012023
Author(s):  
Muslimsyah ◽  
A Munir ◽  
Y Away ◽  
Abdullah ◽  
K Huda ◽  
...  

Abstract Thermal comfort is one of the standard assessments of building thermal environment. Air movement is an important parameter for in a naturally ventilated to achieve thermal comfort by accelerating the evaporative cooling process on the human body. Aceh House has a standard of thermal comfort with a vernacular architecture with a natural ventilation system. This vernacular architectural building has a fairly high harmonization of the environment because it has undergone a process of adaptation. In this study, observations were made at the Original House (OH), the Adaptive Reuse House (ARH), and the Aceh Modified House (AMH). By using the method of assessing changes in environmental comfort, using Wet Bulb Temperature Index (WBGT) method, the minimum and maximum temperature ranges are 25°C and 30°C. In the WBGT thermal rating, AMH has the higher thermal and is followed by ARH and OH respectively. Thus, OH has lower thermal compared to other Aceh houses.


Sign in / Sign up

Export Citation Format

Share Document