Microleakage of a resin sealan using diferents adhesive systems

2018 ◽  
Vol 14 (2) ◽  
Author(s):  
K Licla

Objetive: To compare the microleakage of a resinsealant using fifth generation adhesive systems,seventh generation with or without preconditioningof orthophosphoric acid at 37%. Materials and Methods: An in vitro study wasmade on 60 human premolars, randomized into4 groups of 15 elements each. Group 1 (control):phosphoric acid at 37%, sealant; Group 2: orthophosphoricacid, adhesive of fifth generation, sealant; Group 3: adhesive of seventh generation,sealant; Group 4: orthophosphoric acid, adhesiveof seventh generation, sealant. They were puton a thermocycler, 500 cycles (5° y 55°C) per 30seconds on higher and lower temperatures, afterthat the specimens were drawn for 24 hours on1% methylene blue, cut off on a bucco-lingualway and evaluated on a stereomicroscope on 16x.Chi square test was used with a 0.05 significancelevel. Results: The greater percentage of microleakageshowed: control-adhesive without (53.3%), fifthgeneration (20%), the seventh generation (80%)and conditioning with orthophosphoric acid andadhesive seventh generation (67.7%). Conclusion: Microfiltration grade adhesivesealant fifth generation was lower than using theother adhesives.

2020 ◽  
Vol 9 (10) ◽  
pp. e5639108832
Author(s):  
Paulo Ricardo Barros de Campos ◽  
Lizandra Esper Serrano ◽  
João Victor Frazão Câmara ◽  
Renata Aguiar Costa Di Leta Gregorio ◽  
Raquel Rytholz ◽  
...  

To evaluate the action of photoinitiators on the microtensile resistance of adhesive systems and resins composed in bovine enamel. Forty dental fragments, with flat and smooth enamel surfaces, obtained from the coronary buccal face of healthy bovine incisors, were randomly assigned to 4 experimental groups (n = 10) according to the different adhesive systems and composite resins used: Group 1- Ambar APS + Vittra APS; Group 2- Ambar APS + Opallis; Group 3- Ambar + Vittra APS; Group 4- Ambar + Opallis. After composite restoration, the samples were sectioned to obtain toothpicks that were subjected to the microtensile test (1.0 mm/min). The data obtained were subjected to statistical analysis. The Kruskal-Wallis test revealed no significant differences between groups (p <0.05). Values ​​in MPa were: G1- 18.58 MPaa; G2 - 19.83 MPaa; G3- 19.87 MPaa; G4- 20.99 MPaa. The result of the Mann-Whitney test showed no significant differences due to the adhesive (Ambar Universal- 19.58 MPaa, Ambar APS Universal- 19.87 MPaa) and the composite resin used (Vittra APS- 19.52 MPAa, Opallis - 20.56 MPAa). The use of different photoinitiators in the composition of adhesive systems and restorative composites did not influence their adhesive resistance values ​​due to the standardization of the factors that influence their cure pattern.


2015 ◽  
Vol 5 (2) ◽  
pp. 65-68
Author(s):  
Shruti Patil ◽  
Prajna Shetty

ABSTRACT Background The dentin desensitizers available for in-office application for prevention and/or treatment of post restorative dentinal hypersensitivity, act by blocking the open dentinal tubules. In doing so, they may influence the bond strength of the restorative resins. Thus, the aim of the study was to evaluate the effect of desensitizers on the shear bond strength of dentin adhesives and to check the extent of dentinal tubule occlusion caused by these desensitizers. Materials and Methods Sixty-four premolars were randomly divided into four groups of sixteen each. The middle depth dentin was exposed by on the buccal surface and was etched using 37% phosphoric acid and rinsed. They were assigned to, Group 1: Gluma desensitizer, Group 2: Vivasens desensitizer, Group 3: Gluma Comfort Bond and desensitizer, and Group 4: Adper Single Bond 2. Composite resin post of 2 mm in height and width were built on these specimens. The samples were then mounted in acrylic resin blocks. Universal testing machine was used to test the shear bond strength. The data were analyzed using one-way analysis of variance (ANOVA) and post hoc Tukey's test. Results The mean values of the shear bond strength were for: Group 1—18.61 ± 1.03 MPa, Group 2—17.53 ± 1.36 MPa, Group 3—22.63 ± 1.61 MPa and Group 4—23.12 ± 1.02 MPa. There was a statistically significant difference (p < 0.05) among the groups. Conclusion The use of dentin desensitizers’ influences bond strength between the tooth and the adhesive. Among the various agents, the single bottle system containing Gluma comfort bond and desensitizer had the best adhesion among the desensitizer groups. How to cite this article Patil S, Naik B, Shetty P. A Comparative Evaluation of Three Commercially Available Dentin Desensitizers on the Shear Bond Strength of Composite Resins: An in vitro Study. J Contemp Dent 2015;5(2):65-68.


2019 ◽  
Vol 64 (5) ◽  
pp. 555-562 ◽  
Author(s):  
Marie Kotthaus ◽  
Istabrak Hasan ◽  
Ludger Keilig ◽  
Manfred Grüner ◽  
Christoph Bourauel ◽  
...  

Abstract The aim of this study was to investigate the retention forces of secondary telescopic crowns made of polyetherketoneketone (PEKK) in combination with primary crowns made of four different dental alloys and to determine whether the retention forces change in the course of up to 5000 simulated wear cycles. A total of four groups of telescopic crowns were investigated: group 1: 10 primary crowns made of a gold alloy (NEOCAST®3), group 2: 10 primary crowns made of a non-precious metal alloy (Girobond NB), group 3: 10 primary crowns made of zirconium (Cercon®base) and group 4: 10 primary crowns made from PEKK (Pekkton®ivory). The corresponding secondary crowns were made from PEKK in all the four groups. Each pair was fixed axially in a wear simulator specifically designed for the study. Overall, 10,000 joining and separating cycles were performed for each group. To simulate intraoral conditions, a saliva substitute served as a lubricant. Force transducers were used to record the retention forces and after completing 10,000 cycles, the surface of each primary crown was examined using a scanning electron microscope (SEM). All groups showed an increase in the retention force for the first 2000 cycles which stayed constant for the remaining 8000 cycles. The Pekkton®ivory/Pekkton®ivory and NEOCAST®3/Pekkton®ivory combinations displayed mean retention force values of 16 N after a slight increase in the retention force. The Cercon®base/Pekkton®ivory and Girobond NB/Pekkton®ivory combinations displayed an initially high increase in the retention force and then showed a mean retention force of up to 29 N. All primary crowns displayed surface wear. Zirconium primary crowns showed the least wear compared to PEKK and the gold and non-precious metal alloys.


2021 ◽  
Vol 10 (28) ◽  
pp. 2089-2093
Author(s):  
Sanath Kumar Shetty ◽  
Feba Maria Varghese ◽  
Mohammed Zahid ◽  
Savitha Dandekeri ◽  
Fowzaan Feroz

BACKGROUND This in-vitro study was conducted to compare the effect of different sintering cycles on the surface hardness of full contour monolithic Zirconia. METHODS In this in-vitro study, a total of 28 bar shaped Zirconia samples of final dimensions 20 x 4 x 2 mm were fabricated using Amann Girrbach CAD - CAM unit. These samples were randomly allocated into four groups with 7 samples in each group namely, Group 1, 2, 3 and 4 (Group 1: Long sintering cycle, Group 2: Intermediate sintering cycle, Group 3: Short sintering cycle, Group 4: Ultra-short sintering cycle) and sintered under the respective sintering cycles. The Ceramill® Therm sintering furnace provided 3 sintering cycles ranging from the longest Group - 1 (19 hours), to the short sintering cycle Group - 3 (8 hours), with an intermediate sintering cycle Group - 2 (15hours). The Zircom sintering furnace provided an ultra-short sintering cycle Group - 4 (2 hours). The testing of surface hardness was performed using TECSOL hardness tester. Statistical analysis of the collected data was performed by one - way ANOVA using SPSS software. Multiple comparison was done using post-hoc Tukey’s test. RESULTS One - way ANOVA showed statistically significant difference in the surface hardness of different samples (P < 0.05). The highest mean hardness was observed in Group 3 with 2713.757 + 233.89 VHN, followed by Group 2 with 2595.714 + 62.35 VHN, followed by Group 4 with 2518.600 + 103.65 VHN and Group 1 with the least, 1734.300 + 460.20 VHN. CONCLUSIONS The surface hardness of full contour monolithic Zirconia was influenced to some extent by various sintering cycles. The longest sintering cycle showed the least surface hardness whereas, the short sintering cycle showed the highest surface hardness. Also the ultra-short sintering cycle of 2 hours exhibited surface hardness comparable to the other sintering cycles with longer duration, making it a viable alternative to the conventional sintering cycles. KEY WORDS Monolithic Zirconia, CAD - CAM, Sintering, Hardness


2015 ◽  
Vol 03 (02) ◽  
pp. 103-111
Author(s):  
Jaidev Dhillon ◽  
Sachin Passi ◽  
Ajay Chhabra ◽  
◽  

Abstract Objective: To compare and evaluate the fracture resistance of endodontically treated molars reinforced with various bonded restorations and to study the type of fractures in various restorations. Methods: Forty extracted mandibular molars were endodontically treated. MOD (Mesio-Occluso-Distal) cavities were prepared and Mesio-Buccal cusp was reduced in all to provide cuspal coverage. All the teeth were then divided into 4 groups. The cavities in group 1(control) were filled with high copper amalgam. Group 2 was restored with direct resin composite. In group 3 after the priming and bonding procedures as in group 2, cavity surfaces were coated with flowable resin composite. Before curing a piece of polyethylene ribbon fiber was cut and coated with adhesive resin and was embedded inside the flowable composite. The resin composite was cured with visible light cure (VLC) gun. For group 4, restorations were done according to the recommendations provided by the manufacturers of SR Adoro (Ivoclar-Vivadent, Schaan, Liechtenstein) composite material. Compressive fracture strength test was performed after at least 24 hours of the fabrication of the specimens, by application of compressive loading in a Universal testing machine, applied on the occlusal aspect of each specimen with a steel bar. The mean loads necessary to fracture were recorded in Newton and the results were statistically analyzed. Results: Group 4 (indirect composite inlay) had the greater fracture resistance and group 1(Amalgam) had the poorest. Difference between group 1 and 3, group 1 and 4, group 2 and 4 were statistically significant. No statistically significant difference was found between group 1 and 2, group 2 and 3, group 3 and 4. Predominant type of fracture in group 1 and 3 was fracture of tooth below cemento enamel junction at tooth restoration interface without mesio buccal cusp involvement. In group 2 and 4, predominant fractures were of tooth below cemento enamel junction through center of restoration without mesio–buccal cusp involvement.


2020 ◽  
Vol 79 (Suppl 1) ◽  
pp. 340.2-341
Author(s):  
V. Orefice ◽  
F. Ceccarelli ◽  
C. Barbati ◽  
R. Lucchetti ◽  
G. Olivieri ◽  
...  

Background:Systemic lupus erythematosus (SLE) is an autoimmune disease mainly affecting women of childbearing age. The interplay between genetic and environmental factors may contribute to disease pathogenesis1. At today, no robust data are available about the possible contribute of diet in SLE. Caffeine, one of the most widely consumed products in the world, seems to interact with multiple components of the immune system by acting as a non-specific phosphodiesterase inhibitor2.In vitrodose-dependent treatment with caffeine seems to down-regulate mRNA levels of key inflammation-related genes and similarly reduce levels of different pro-inflammatory cytokines3.Objectives:We evaluated the impact of caffeine consumption on SLE-related disease phenotype and activity, in terms of clinimetric assessment and cytokines levels.Methods:We performed a cross-sectional study, enrolling consecutive patients and reporting their clinical and laboratory data. Disease activity was assessed by SLE Disease Activity Index 2000 (SLEDAI-2k)4. Caffeine intake was evaluated by a 7-day food frequency questionnaire, including all the main sources of caffeine. As previously reported, patients were divided in four groups according to the daily caffeine intake: <29.1 mg/day (group 1), 29.2-153.7 mg/day (group 2), 153.8-376.5 mg/day (group 3) and >376.6 mg/day (group 4)5. At the end of questionnaire filling, blood samples were collected from each patient to assess cytokines levels. These were assessed by using a panel by Bio-Plex assays to measure the levels of IL-6, IL-10, IL-17, IL-27, IFN-γ, IFN-α and Blys.Results:We enrolled 89 SLE patients (F/M 87/2, median age 46 years, IQR 14; median disease duration 144 months, IQR 150). The median intake of caffeine was 195 mg/day (IQR 160.5). At the time of the enrollment, 8 patients (8.9%) referred a caffeine intake < 29.1 mg/day (group 1), 27 patients (30.3%) between 29.2 and 153.7 mg/day (group 2), 45 patients (51%) between 153.8 and 376.5 mg/day (group 3) and 9 patients (10.1%) >376.6 mg/day (group 4). A negative correlation between the levels of caffeine and disease activity, evaluated with SLEDAI-2K, was observed (p=0.01, r=-0.26). By comparing the four groups, a significant higher prevalence of lupus nephritis, neuropsychiatric involvement, haematological manifestations, hypocomplementemia and anti-dsDNA positivity was observed in patients with less intake of caffeine (figure 1 A-E). Furthermore, patients with less intake of caffeine showed a significant more frequent use of glucocorticoids [group 4: 22.2%,versusgroup 1 (50.0%, p=0.0001), group 2 (55.5%, p=0.0001), group 3 (40.0%, p=0.009)]. Moving on cytokines analysis, a negative correlation between daily caffeine consumption and serum level of IFNγ was found (p=0.03, r=-0.2) (figure 2A); furthermore, patients with more caffeine intake showed significant lower levels of IFNα (p=0.02, figure 2B), IL-17 (p=0.01, figure 2C) and IL-6 (p=0.003, figure 2D).Conclusion:This is the first report demonstrating the impact of caffeine on SLE disease activity status, as demonstrated by the inverse correlation between its intake and both SLEDAI-2k values and cytokines levels. Moreover, in our cohort, patients with less caffeine consumption seems to have a more severe disease phenotype, especially in terms of renal and neuropsychiatric involvement. Our results seem to suggest a possible immunoregulatory dose-dependent effect of caffeine, through the modulation of serum cytokine levels, as already suggested byin vitroanalysis.References:[1]Kaul et alNat. Rev. Dis. Prim.2016; 2. Aronsen et alEurop Joul of Pharm2014; 3. Iris et alClin Immun.2018; 4. Gladman et al J Rheumatol. 2002; 5. Mikuls et alArth Rheum2002Disclosure of Interests:Valeria Orefice: None declared, Fulvia Ceccarelli: None declared, cristiana barbati: None declared, Ramona Lucchetti: None declared, Giulio Olivieri: None declared, enrica cipriano: None declared, Francesco Natalucci: None declared, Carlo Perricone: None declared, Francesca Romana Spinelli Grant/research support from: Pfizer, Consultant of: Novartis, Gilead, Lilly, Sanofi, Celgene, Speakers bureau: Lilly, cristiano alessandri Grant/research support from: Pfizer, Guido Valesini: None declared, Fabrizio Conti Speakers bureau: BMS, Lilly, Abbvie, Pfizer, Sanofi


2010 ◽  
Vol 04 (04) ◽  
pp. 367-373 ◽  
Author(s):  
Sevi Burcak Cehreli ◽  
Asli Guzey ◽  
Neslihan Arhun ◽  
Alev Cetinsahin ◽  
Bahtiyar Unver

Objectives: The aim of this in vitro study is to determine (1) shear bond strength (SBS) of brackets bonded with self-etch and total-etch adhesive after ozone treatment (2) bond failure interface using a modified Adhesive Remnant Index (ARI).Methods: 52 premolars were randomly assigned into four groups (n=13) and received the following treatments: Group 1: 30 s Ozone (Biozonix, Ozonytron, Vehos Medikal, Ankara, Turkey) application + Transbond Plus Self-Etching Primer (SEP) (3M) + Transbond XT (3M), Group 2: Transbond Plus SEP + Transbond XT, Group 3: 30 s Ozone application + 37% orthophosphoric acid + Transbond XT Primer (3M) + Transbond XT, Group 4: 37% orthophosphoric acid + Transbond XT Primer + Transbond XT. All samples were stored in deionised water at 37oC for 24 hours. Shear debonding test was performed by applying a vertical force to the base of the bracket at a cross-head speed of 1 mm/min.Results: The mean SBS results were Group 1: 10.48 MPa; Group 2: 8.89 MPa; Group 3: 9.41 MPa; Group 4: 9.82 MPa. One-Way Variance Test revealed that the difference between the groups was not statistically significant (P=0.267). Debonded brackets were examined by an optical microscope at X16 magnification to determine the bond failure interface using a modified ARI. The results were (mean) Group 1: 2.38; Group 2: 1.31; Group 3: 3.00; Group 4: 1.92. Multiple comparisons showed that Groups 1 and 2, 2 and 3, 3 and 4 were statistically different (P=0.014, P<.001 and P=0.025).Conclusions: Ozone treatment prior to bracket bonding does not affect the shear bond strength. (Eur J Dent 2010;4:367-373)


Scientifica ◽  
2015 ◽  
Vol 2015 ◽  
pp. 1-6
Author(s):  
Vedavathi Bore Gowda ◽  
B. V. Sreenivasa Murthy ◽  
Swaroop Hegde ◽  
Swapna Devarasanahalli Venkataramanaswamy ◽  
Veena Suresh Pai ◽  
...  

Aim. To compare the microleakage in class II composite restorations without a liner/with resin modified glass ionomer and flowable composite liner.Method. Forty standardized MO cavities were prepared on human permanent mandibular molars extracted for periodontal reasons and then divided into 4 groups of ten specimens. The cavity preparations were etched, rinsed, blot dried, and light cured and Adper Single Bond 2 is applied. Group 1 is restored with Filtek P60 packable composite in 2 mm oblique increments. Group 2 is precure group where 1 mm Filtek Z350 flowable liner is applied and light cured for 20 sec. Group 3 is the same as Group 2, but the liner was cocured with packable composite. In Group 4, 1 mm RMGIC, Fuji Lining LC is applied and cured for 20 sec. All the teeth were restored as in Group 1. The specimens were coated with nail varnish leaving 1 mm around the restoration, subjected to thermocycling, basic fuchsin dye penetration, sectioned mesiodistally, and observed under a stereomicroscope.Results. The mean leakage scores of the individual study groups were Group 1 (33.40), Group 2 (7.85), Group 3 (16.40), and Group 4 (24.35). Group 1 without a liner showed maximum leakage. Flowable composite liner precured was the best.


1994 ◽  
Vol 6 (2) ◽  
pp. 207-215 ◽  
Author(s):  
Bradd C. Barr ◽  
Joan D. Rowe ◽  
Karen W. Sverlow ◽  
Robert H. BonDurant ◽  
Alex A. Ardans ◽  
...  

Studies were conducted to determine the pathogenic potential of the recently isolated bovine Neospora protozoa (BPA-1) for the bovine fetus. Cows chosen for study had Neospora titers < 160 using an indirect immunofluorescent antibody (IFA) test. Four experimental groups were studied. In group 1, 2 fetuses were inoculated in utero at 118 days gestation with culture-derived Neospora tachyzoites. A pregnant control cow was housed in the same pen, observed daily and screened serologically for evidence of exposure to Neospora. In group 2, 2 cows were infected with Neospora tachyzoites at 138 or 161 days gestation, and 1 control cow was given uninfected cell culture suspension simultaneously at 154 days gestation. Groups 3 (85 days gestation) and 4 (120 days gestation) each consisted of 2 cows infected with Neospora tachyzoites and 1 control cow given uninfected material at the same stage of gestation. Dead fetuses were surgically removed from the infected cows in group 1 on postinfection day (PID) 17. The histopathology was compatible with protozoal fetal infection, and protozoa were identified by immunohistochemistry. Viable fetuses were removed surgically from cows in group 2 on PID 28-30. The histopathology was compatible with protozoal fetal infection, protozoa were identified by immunoperoxidase techniques, and Neospora tachyzoites were reisolated in vitro from tissues of the 2 infected fetuses. In groups 3 and 4, the control fetus and 1 infected fetus were removed surgically between PID 26 and PID 33. The remaining infected cows were observed until fetal death or abortion occurred. In group 3, the fetus that was surgically removed from 1 infected cow had no pathologic abnormalities, and parasites were not found (PID 26). The second fetus in group 3 died in utero, and expulsion of a mummified fetus was induced on PID 67. Brain histopathology was compatible with protozoal infection, and parasites were identified by immunoperoxidase techniques. The fetus that was surgically removed (PID 32) from 1 infected cow in group 4 had lesions compatible with protozoal infection, and Neospora tachyzoites were reisolated in vitro from fetal tissues. The second infected cow in group 4 produced a full-term live calf that had a precolostral Neospora titer of 20,480. Clinically, this calf had depressed conscious proprioception in all limbs. Very mild lesions were found in the central nervous system, but protozoa were not found in the tissues. The results demonstrate that the bovine Neospora protozoa can be transplacentally transmitted, resulting in fetal infection and death, and mimics the naturally occurring fetal disease.


Author(s):  
Deebah Choudhary

Aim: The aim of this study was to evaluate the canal cleaning efficacy of these three file systems using scanning electron microscopy. Place and Duration of Study: The study was conducted in the Department of Conservative dentistry and Endodontics, Institute of Dental Sciences Sehora, between October 2020 and December 2020. Materials and Methods: Access cavity preparation was performed on sixty extracted human mandibular premolar teeth and working length was determined. The samples were randomly divided into three groups (n=20) depending upon the file system used i.e. Group 1 (Reciproc Blue), Group 2 (Waveone Gold) and Group 3 (F360). Samples were split into two halves by creating longitudinal grooves on the buccal and lingual surfaces. The samples were sputter-coated with gold and examined under scanning electron microscope at 5000X. The dentinal wall of root canal at coronal, middle and apical thirds of each sample were evaluated for the presence of determining the canal cleanliness and then analyzed using a five-score index. Results: The results of this study revealed that Group 1 (Reciproc Blue) exhibited better cleaning efficacy than samples of Group 2 (WaveOne Gold) and Group 3 (F360) at different locations in the canal i.e. coronal, middle and apical. The mean debris present was highest in coronal area for both group 2 and group 3 i.e. 2.1 and least was seen in apical area of group 1 i.e. 0.3. (p<0.05) Conclusion: Reciproc Blue single-file showed highest cleaning efficacy followed by Waveone Gold and F360. Reciproc file also showed effective cleaning in the apical third of the canal.


Sign in / Sign up

Export Citation Format

Share Document