morphological parameter
Recently Published Documents


TOTAL DOCUMENTS

43
(FIVE YEARS 18)

H-INDEX

7
(FIVE YEARS 2)

Author(s):  
HEDIEH PAZOKIAN ◽  
MOHAMMAD REZA RASHIDIAN VAZIRI

Laser irradiation is used for surface modification of polymers aiming to improve their properties for different applications. The wettability of a polymeric surface can significantly affect its performance for biological applications. In this paper, the interaction of high-energy KrF laser photons in the two above- and below-threshold regimes with polyethersulfone polymer is studied. The role of morphological and chemical changes of the irradiated polymer and their correlation in the modification of the wetting property of this polymer is investigated. The obtained results show that the morphological parameter of surface roughness is the dominant mechanism in the below-threshold regime, while in the above-threshold region, the competition between this parameter and the carbonization amount of the surface determines the final hydrophilic response.


2021 ◽  
Vol 3 (2) ◽  
Author(s):  
Maurice O Oyugi

Various postulations on the relationship between urban morphology and air quality are qualitative. This fails to establish the strength of the contributions of each morphological parameter in the spatial distribution of the air quality. It is this gap in knowledge that this study sought to fill by modelling the correlation existing between the urban morphological variables of development density, land uses, biomass index and air quality values of Nairobi city. While 30 development zones of the city constituted the target population, IKONOS satellite imagery of the city for the year 2015 was utilised in establishing the development densities, land uses and biomass index. The parameters were transformed into numerical surrogates ranging from 1 to 10 with lower values accorded to zones with low biomass index, the highest development density, noxious land uses, high gaseous concentrations and vice-versa. Pearson’s correlation coefficients (r), coefficients of determination (R), t-tests and the Analysis of Variance (F-tests) with levels of significance being 95% were used to determine the strengths, significances and consistencies of the established relationships. The study established that development density is the most significant morphological variable influencing the distribution of air quality. This is followed by biomass index and to a weaker extent, land uses.


Medicine ◽  
2021 ◽  
Vol 100 (34) ◽  
pp. e27084
Author(s):  
Hye-Won Jeong ◽  
Jungmin Yi ◽  
Sooho Lee ◽  
Sukhee Park ◽  
Keum Nae Kang ◽  
...  

Author(s):  
Hui Zhang ◽  
Lei Tian ◽  
Lili Guo ◽  
Xiao Qin ◽  
Di Zhang ◽  
...  

Abstract Objective To more comprehensively evaluate the ability of the parameters reflecting the morphological and biomechanical properties of the cornea to distinguish clinical keratoconus (CKC) and forme fruste keratoconus (FFKC) from normal. Methods Normal eyes (n = 50), CKC (n = 45) and FFKC (n = 15) were analyzed using Pentacam, Corvis ST and ORA. Stepwise logistic regression of all parameters was performed to obtain the optimal combination model capable of distinguishing CKC, FFKC from normal, named SLR1 and SLR2, respectively. Receiver operating characteristic (ROC) curves were applied to determine the predictive accuracy of the parameters and the two combination models, as described by the area under the curve (AUC). AUCs were compared using the DeLong method. Results The SLR1 model included only the TBI output by Pentacam, while the SLR2 model included the morphological parameter F.Ele.Th and two parameters from the Corvis ST, HC DfA and SP-A1. The majority of the parameters had sufficient strength to differentiate the CKC from normal corneas, even the seven separate parameters and the SLR1 model had a discrimination efficiency of 100%. The predictive accuracy of the parameters was moderate for FFKC, and the SLR2 model (0.965) presented an excellent AUC, followed by TBI, F.Ele.Th and BAD-D. Conclusion The F.Ele.Th from Pentacam was the most sensitive morphological parameter for FFKC, and the combination of F.Ele.Th, HC DfA and SP-A1 made the diagnosis of FFKC more efficient. The CRF and CH output by ORA did not improve the combined diagnosis, despite the corneal combination of morphological and biomechanical properties that optimized the diagnosis of FFKC.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Carla C. Polo ◽  
Miriam H. Fonseca-Alaniz ◽  
Jian-Hua Chen ◽  
Axel Ekman ◽  
Gerry McDermott ◽  
...  

AbstractMitochondria are dynamic organelles that change morphology to adapt to cellular energetic demands under both physiological and stress conditions. Cardiomyopathies and neuronal disorders are associated with structure-related dysfunction in mitochondria, but three-dimensional characterizations of the organelles are still lacking. In this study, we combined high-resolution imaging and 3D electron density information provided by cryo-soft X-ray tomography to characterize mitochondria cristae morphology isolated from murine. Using the linear attenuation coefficient, the mitochondria were identified (0.247 ± 0.04 µm−1) presenting average dimensions of 0.90 ± 0.20 µm in length and 0.63 ± 0.12 µm in width. The internal mitochondria structure was successfully identified by reaching up the limit of spatial resolution of 35 nm. The internal mitochondrial membranes invagination (cristae) complexity was calculated by the mitochondrial complexity index (MCI) providing quantitative and morphological information of mitochondria larger than 0.90 mm in length. The segmentation to visualize the cristae invaginations into the mitochondrial matrix was possible in mitochondria with MCI ≥ 7. Altogether, we demonstrated that the MCI is a valuable quantitative morphological parameter to evaluate cristae modelling and can be applied to compare healthy and disease state associated to mitochondria morphology.


2020 ◽  
Vol 11 (4) ◽  
pp. 705-710
Author(s):  
Martin K. Walz ◽  
Klaus A. Metz ◽  
Sarah Theurer ◽  
Cathrin Myland ◽  
Pier F. Alesina ◽  
...  

AbstractThe morphological differentiation between benign and malignant adrenocortical tumors is an ongoing problem in diagnostic pathology. In recent decades the complex scoring systems have been widely used to calculate the probability of malignancy in adrenocortical tumors on the basis of a variety of histomorphological parameters. We herewith present a substantially simplified method to diagnose adrenocortical carcinoma by a single histomorphological parameter on a consecutive series of more than 800 adrenocortical tumors. Between January 2000 and May 2019, altogether 2305 adrenalectomies for of all types of diseases were removed, approximately 98% by minimally invasive approaches. After exclusion of pheochromocytomas, adrenal ganglioneuromas, adrenal metastases, Cushing’s disease related specimens, and Conn’s adenomas, the present series finally consisted of 837 adrenocortical tumors. All tumors were analyzed by experienced pathologists of a single institution using standard histopathological methods (Hematoxylin-Eosin and Ki67 stained sections). Clinical and histopathologic data were prospectively collected and retrospectively analyzed. Clinically, 385 patients had 420 functioning tumors (FT), and 417 had non-functioning adrenal tumors (NFT). The mean size of FT was 3.8 ± 1.4 cm (range 0.5–16 cm) and for NFT 4.5 ± 1.6 cm (range 1.5–18 cm). Histomorphologically, 32 adrenal tumors were classified as adrenocortical carcinoma (ACC; 3.8%). In all 32 cases (tumor size 9.1 ± 4.0 cm, range 3–18 cm), confluenting tumor necrosis could be demonstrated. The remaining 805 tumors (control group) completely lacked this highly reproducible single morphological feature. Ki67 levels above 10% were found in 31 of 32 ACCs and never in adrenocortical adenomas (ACA). With a mean follow-up of 8.2 years, 24 out of 32 patients primarily diagnosed as ACC developed distant metastases (75.0%), whereas all patients in the control group remained free of local or distant recurrence. We conclude that a single morphological parameter (confluenting tumor necrosis) is sufficient to predict a poor clinical course in adrenocortical tumors. The histomorphological diagnosis of this parameter is straightforward and highly reproducible.


Sign in / Sign up

Export Citation Format

Share Document