corneal tissue
Recently Published Documents


TOTAL DOCUMENTS

578
(FIVE YEARS 189)

H-INDEX

40
(FIVE YEARS 5)

2022 ◽  
pp. medethics-2021-108003
Author(s):  
Katrina A Bramstedt

This brief report presents the global problem of the shortfall of donor corneal tissue for transplantation, a potential root cause (‘ick factor’ language), and a potential solution (modification of ‘ick factor’ language). Specifically, use of the term ‘eye donation’ is a potential hurdle to ocular tissue donation as it can stimulate the ‘ick factor.’ Verbiage such as ‘ocular (eye tissue)’ could be a method of providing terminology that is less emotive than ‘eye donor’ or ‘eye donation.’ The field of transplantation has experienced terminology shifts over time; for example, ‘cadaver’ has been replaced with ‘deceased donor,’ ‘harvest’ has been replaced with ‘recover,’ and ‘life support’ has been replaced with ‘ventilated.’ Notably, only a small number of regions worldwide are using ‘ocular’ terminology, yet it could be an important step to enhancing the informed consent process and improving donation rates, potentially increasing transplant and optimising patient quality of life for those with treatable blindness.


Cells ◽  
2022 ◽  
Vol 11 (1) ◽  
pp. 178
Author(s):  
Nur Zahirah binte M. Yusoff ◽  
Andri K. Riau ◽  
Gary H. F. Yam ◽  
Nuur Shahinda Humaira binte Halim ◽  
Jodhbir S. Mehta

The human corneal stroma contains corneal stromal keratocytes (CSKs) that synthesize and deposit collagens and keratan sulfate proteoglycans into the stromal matrix to maintain the corneal structural integrity and transparency. In adult corneas, CSKs are quiescent and arrested in the G0 phase of the cell cycle. Following injury, some CSKs undergo apoptosis, whereas the surviving cells are activated to become stromal fibroblasts (SFs) and myofibroblasts (MyoFBs), as a natural mechanism of wound healing. The SFs and MyoFBs secrete abnormal extracellular matrix proteins, leading to corneal fibrosis and scar formation (corneal opacification). The issue is compounded by the fact that CSK transformation into SFs or MyoFBs is irreversible in vivo, which leads to chronic opacification. In this scenario, corneal transplantation is the only recourse. The application of cell therapy by replenishing CSKs, propagated in vitro, in the injured corneas has been demonstrated to be efficacious in resolving early-onset corneal opacification. However, expanding CSKs is challenging and has been the limiting factor for the application in corneal tissue engineering and cell therapy. The supplementation of serum in the culture medium promotes cell division but inevitably converts the CSKs into SFs. Similar to the in vivo conditions, the transformation is irreversible, even when the SF culture is switched to a serum-free medium. In the current article, we present a detailed protocol on the isolation and propagation of bona fide human CSKs and the morphological and genotypic differences from SFs.


2022 ◽  
Vol 70 (1) ◽  
pp. 299
Author(s):  
Radhika Natarajan ◽  
Niveditha Narayanan
Keyword(s):  

2021 ◽  
Vol 6 (6-1) ◽  
pp. 229-236
Author(s):  
A. V. Tereshchenko ◽  
I. G. Trifanenkova ◽  
Yu. Y. Golubeva ◽  
S. K. Demianchenko ◽  
E. N. Vishnyakova

For the treatment of progressive keratoconus in the early stages, corneal collagen crosslinking is currently actively used. This technique is based on the stabilization of the pathological process by increasing the biomechanical properties of the own cornea. The thickness of the cornea less than 400 microns significantly limits the possibility of a standard cross-linking procedure performing.The article analyzes the literature data on the use of various methods of corneal crosslinking with a corneal thickness of less than 400 microns, which signifi cantly limits the possibilities of the standard procedure.It is known, that during crosslinking, at the initial stage, de-epithelialization of the cornea is performed, which, in the postoperative period, leads to a pronounced corneal syndrome. This determined the direction of the fi rst modifi cations of the technique associated with the use of partial de-epithelialization or its complete absence. Later, during cross-linking of “thin” corneas, techniques with the use of additional covering materials were actively used in order to replenish the missing corneal tissue of the patient during the UV irradiation procedure. Among them are the use of a soft contact lens without an ultraviolet fi lter, the use of a corneal lenticule obtained after SMILE surgery, the use of a protective fl ap of the donor cornea obtained using a femtosecond laser from the residual stroma of the corneal disc after descemet membrane transplantation or posterior lamellar keratoplasty. The variety of the proposed modifications and the ongoing search for better options indicate the demand for this technology and the need for further research, taking into account the individual characteristics of the patient’s ectasia.


Author(s):  
Guihua Liu ◽  
Hua Rong ◽  
Ping Zhang ◽  
Yu Xue ◽  
Bei Du ◽  
...  

Background: To investigate the correlation between the corneal biomechanical parameter stress-strain index (SSI) and axial length (AL) in moderately elongated eye (MEE) and severely elongated eye (SEE).Methods: This study included 117 eyes from 117 participants. Among them, 59 (50.4%) had MEE (AL<26 mm) and 58 (49.6%) had SEE (AL≥26 mm). AL was measured using Lenstar LS-900, and central corneal thickness (CCT) and anterior chamber volume (ACV) were measured using Pentacam. SSI was measured via corneal visualisation Scheimpflug technology (Corvis ST). Kolmogorov-Smirnov test, Student’s t-test, and Pearson and partial correlation analyses were used for statistical analyses.Results: The mean (±SD) SSI was 1.08 ± 0.15 in the MEE group and 0.92 ± 0.13 in the SEE group (p < 0.01). SSI was positively correlated with age (MEE: r = 0.326, p < 0.05; SEE: r = 0.298, p < 0.05) in both groups; it was negatively correlated with AL (r = −0.476, p < 0.001) in the MEE group but not in the SEE group (p > 0.05). CCT was negatively correlated with AL (r = −0.289, p < 0.05) and ACV positively correlated with AL (r = 0.444, p < 0.001) in the MEE group. Neither CCT nor ACV was correlated with AL (p > 0.05) in the SEE group.Conclusion: Corneal biomechanical parameter SSI, which represents the stiffness of corneal tissue, was lower in the SEE group than in the MEE group. When analyzed separately, SSI was negatively correlated with AL in the MEE group, but not in the SEE group, which may provide insight into different ocular growth patterns between lower myopia and higher myopia.


2021 ◽  
Author(s):  
Mei Sun ◽  
Devon Cogswell ◽  
Sheila Adams ◽  
Yasmin Ayoubi ◽  
Ambuj Kumar ◽  
...  

Collagen XI plays a role in nucleating collagen fibrils and in controlling fibril diameter. The aim of this research is to elucidate the role that collagen XI plays in corneal fibrillogenesis during development and following injury. The temporal and spatial expression of collagen XI was evaluated in C57BL/6 wild type (WT) mice. For wound healing studies in adult mice, stromal injuries were created using techniques that avoid caustic chemicals. The temporal expression and spatial localization of collagen XI was studied following injury in a Col11a1 inducible knockout mouse model. We found that collagen XI expression occurs during early maturation and is upregulated after stromal injury in areas of regeneration and remodeling. Abnormal fibrillogenesis with new fibrils of heterogenous size and shape occurs after injury in a decreased collagen XI matrix. In conclusion, we found that collagen XI is expressed in the stroma during development and following injury in adults. Collagen XI is a regulator of collagen fibrillogenesis in regenerating corneal tissue.


PLoS ONE ◽  
2021 ◽  
Vol 16 (11) ◽  
pp. e0260494
Author(s):  
Ibrahim Abdelhalim ◽  
Omnia Hamdy ◽  
Aziza Ahmed Hassan ◽  
Salah Hassab Elnaby

Corneal reshaping is a common medical procedure utilized for the correction of different vision disorders relying on the ablation effect of the UV pulsed lasers, especially excimer lasers (ArF) at 193 nm. This wavelength is preferred in such medical procedures since laser radiation at 193 nm exhibits an optimum absorption by corneal tissue. However, it is also significantly absorbed by the water content of the cornea resulting in an unpredictability in the clinical results, as well as the high service and operation cost of the commercial ArF excimer laser device. Consequently, other types of solid-state UV pulsed lasers have been introduced. The present work investigates the ablation effect of solid-state laser at 266 nm in order to be utilized in corneal reshaping procedures. Different number of pulses has been applied to Polymethyl Methacrylate (PMMA) and ex-vivo rabbit cornea to evaluate the ablation effect of the produced laser radiation. PMMA target experienced ellipse-like ablated areas with a conical shape in the depth. The results revealed an almost constant ablation area regardless the number of laser pulses, which indicates the stability of the produced laser beam, whereas the ablation depth increases only with increasing the number of laser pulses. Examination of the ex-vivo cornea showed a significant tissue undulation, minimal thermal damage, and relatively smooth ablation surfaces. Accordingly, the obtained 266-nm laser specifications provide promising alternative to the traditional 193-nm excimer laser in corneal reshaping procedure.


2021 ◽  
Vol 11 (23) ◽  
pp. 11292
Author(s):  
Claudia Muñoz-Villaescusa ◽  
Osiris de la C. Núñez-Chongo ◽  
Taimi Cárdenas-Díaz ◽  
Alfo J. Batista-Leyva ◽  
Francisco Cavas-Martínez

Corneal biomechanics aims to establish the physico-mathematical bases that allow for predicting the corneal response to physiological and pathological situations by creating models of tissue behavior. Determining the characteristic parameters of these models is a formidable challenge in the biomechanical modeling process. To contribute to corneal tissue characterization, an experimental set-up was designed, built and tested to study corneal behavior by applying changes in pressure. The elastic constants of porcine corneas were determined, and a Young’s modulus of 0.188 MPa and 26.22% hysteresis were obtained. A computational cornea model was developed to analyze the influence of different factors. Minor variations in the applied conditions were found for apical displacement and pachymetry, and the corneal behavior was reproduced. However, the optical power behavior was affected by variations in the applied conditions, and the experimentally obtained data could not be reproduced. Despite its importance, this parameter has not been analyzed in-depth by other studies, which shows that the quality of a biomechanical cornea model should not be evaluated only by apical displacement.


Nanomaterials ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 3191
Author(s):  
Marcus Himmler ◽  
Dirk W. Schubert ◽  
Thomas A. Fuchsluger

The transparency of nanofibrous scaffolds is of highest interest for potential applications like corneal wound dressings in corneal tissue engineering. In this study, we provide a detailed analysis of light transmission through electrospun polycaprolactone (PCL) scaffolds. PCL scaffolds were produced via electrospinning, with fiber diameters in the range from (35 ± 13) nm to (167 ± 35) nm. Light transmission measurements were conducted using UV–vis spectroscopy in the range of visible light and analyzed with respect to the influence of scaffold thickness, fiber diameter, and surrounding medium. Contour plots were compiled for a straightforward access to light transmission values for arbitrary scaffold thicknesses. Depending on the fiber diameter, transmission values between 15% and 75% were observed for scaffold thicknesses of 10 µm. With a decreasing fiber diameter, light transmission could be improved, as well as with matching refractive indices of fiber material and medium. For corneal tissue engineering, scaffolds should be designed as thin as possible and fabricated from polymers with a matching refractive index to that of the human cornea. Concerning fiber diameter, smaller fiber diameters should be favored for maximizing graft transparency. Finally, a novel, semi-empirical formulation of light transmission through nanofibrous scaffolds is presented.


2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Tobias Kehrer ◽  
Samuel Arba Mosquera

Abstract In this paper, we present a cornea deformation model based on the idea of extending the ‘neutral axis’ model to two-dimensional deformations. Considering this simple model, assuming the corneal tissue to behave like a continuous, isotropic and non-compressible material, we are able to partially describe, e.g., the observed deviation in refractive power after lenticule extraction treatments. The model provides many input parameters of the patient and the treatment itself, leading to an individual compensation ansatz for different setups. The model is analyzed for a reasonable range of various parameters. A semi-quantitative comparison to real patient data is performed.


Sign in / Sign up

Export Citation Format

Share Document