asynchrony index
Recently Published Documents


TOTAL DOCUMENTS

14
(FIVE YEARS 8)

H-INDEX

3
(FIVE YEARS 0)

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Filippo Bongiovanni ◽  
Domenico Luca Grieco ◽  
Gian Marco Anzellotti ◽  
Luca Salvatore Menga ◽  
Teresa Michi ◽  
...  

Abstract Background There is growing interest towards the use of helmet noninvasive ventilation (NIV) for the management of acute hypoxemic respiratory failure. Gas conditioning through heat and moisture exchangers (HME) or heated humidifiers (HHs) is needed during facemask NIV to provide a minimum level of humidity in the inspired gas (15 mg H2O/L). The optimal gas conditioning strategy during helmet NIV remains to be established. Methods Twenty patients with acute hypoxemic respiratory failure (PaO2/FiO2 < 300 mmHg) underwent consecutive 1-h periods of helmet NIV (PEEP 12 cmH2O, pressure support 12 cmH2O) with four humidification settings, applied in a random order: double-tube circuit with HHs and temperature set at 34 °C (HH34) and 37 °C (HH37); Y-piece circuit with HME; double-tube circuit with no humidification (NoH). Temperature and humidity of inhaled gas were measured through a capacitive hygrometer. Arterial blood gases, discomfort and dyspnea through visual analog scales (VAS), esophageal pressure swings (ΔPES) and simplified pressure–time product (PTPES), dynamic transpulmonary driving pressure (ΔPL) and asynchrony index were measured in each step. Results Median [IqR] absolute humidity, temperature and VAS discomfort were significantly lower during NoH vs. HME, HH34 and HH37: absolute humidity (mgH2O/L) 16 [12–19] vs. 28 [23–31] vs. 28 [24–31] vs. 33 [29–38], p < 0.001; temperature (°C) 29 [28–30] vs. 30 [29–31] vs. 31 [29–32] vs 32. [31–33], p < 0.001; VAS discomfort 4 [2–6] vs. 6 [2–7] vs. 7 [4–8] vs. 8 [4–10], p = 0.03. VAS discomfort increased with higher absolute humidity (p < 0.01) and temperature (p = 0.007). Higher VAS discomfort was associated with increased VAS dyspnea (p = 0.001). Arterial blood gases, respiratory rate, ΔPES, PTPES and ΔPL were similar in all conditions. Overall asynchrony index was similar in all steps, but autotriggering rate was lower during NoH and HME (p = 0.03). Conclusions During 1-h sessions of helmet NIV in patients with hypoxemic respiratory failure, a double-tube circuit with no humidification allowed adequate conditioning of inspired gas, optimized comfort and improved patient–ventilator interaction. Use of HHs or HME in this setting resulted in increased discomfort due to excessive heat and humidity in the interface, which was associated with more intense dyspnea. Trail Registration Registered on clinicaltrials.gov (NCT02875379) on August 23rd, 2016.


2021 ◽  
Vol 8 ◽  
Author(s):  
Ling Liu ◽  
Yue Yu ◽  
Xiaoting Xu ◽  
Qin Sun ◽  
Haibo Qiu ◽  
...  

Background: Patient-ventilator asynchrony is common during pressure support ventilation (PSV) because of the constant cycling-off criteria and variation of respiratory system mechanical properties in individual patients. Automatic adjustment of inspiratory triggers and cycling-off criteria based on waveforms might be a useful tool to improve patient-ventilator asynchrony during PSV.Method: Twenty-four patients were enrolled and were ventilated using PSV with different cycling-off criteria of 10% (PS10), 30% (PS30), 50% (PS50), and automatic adjustment PSV (PSAUTO). Patient-ventilator interactions were measured.Results: The total asynchrony index (AI) and NeuroSync index were consistently lower in PSAUTO when compared with PS10, PS30, and PS50, (P &lt; 0.05). The benefit of PSAUTO in reducing the total AI was mainly because of the reduction of the micro-AI but not the macro-AI. PSAUTO significantly improved the relative cycling-off error when compared with prefixed controlled PSV (P &lt; 0.05). PSAUTO significantly reduced the trigger error and inspiratory effort for the trigger when compared with a prefixed trigger. However, total inspiratory effort, breathing patterns, and respiratory drive were not different among modes.Conclusions: When compared with fixed cycling-off criteria, an automatic adjustment system improved patient-ventilator asynchrony without changes in breathing patterns during PSV. The automatic adjustment system could be a useful tool to titrate more personalized mechanical ventilation.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Anne-Fleur Haudebourg ◽  
Tommaso Maraffi ◽  
Samuel Tuffet ◽  
François Perier ◽  
Nicolas de Prost ◽  
...  

Abstract Background Ineffective triggering is frequent during pressure support ventilation (PSV) and may persist despite ventilator adjustment, leading to refractory asynchrony. We aimed to assess the effect of proportional assist ventilation with load-adjustable gain factors (PAV+) on the occurrence of refractory ineffective triggering. Design Observational assessment followed by prospective cross-over physiological study. Setting Academic medical ICU. Patients Ineffective triggering was detected during PSV by a twice-daily inspection of the ventilator’s screen. The impact of pressure support level (PSL) adjustments on the occurrence of asynchrony was recorded. Patients experiencing refractory ineffective triggering, defined as persisting asynchrony at the lowest tolerated PSL, were included in the physiological study. Interventions Physiological study: Flow, airway, and esophageal pressures were continuously recorded during 10 min under PSV with the lowest tolerated PSL, and then under PAV+ with the gain adjusted to target a muscle pressure between 5 and 10 cmH2O. Measurements Primary endpoint was the comparison of asynchrony index between PSV and PAV+ after PSL and gain adjustments. Results Among 36 patients identified having ineffective triggering under PSV, 21 (58%) exhibited refractory ineffective triggering. The lowest tolerated PSL was higher in patients with refractory asynchrony as compared to patients with non-refractory ineffective triggering. Twelve out of the 21 patients with refractory ineffective triggering were included in the physiological study. The median lowest tolerated PSL was 17 cmH2O [12–18] with a PEEP of 7 cmH2O [5–8] and FiO2 of 40% [39–42]. The median gain during PAV+ was 73% [65–80]. The asynchrony index was significantly lower during PAV+ than PSV (2.7% [1.0–5.4] vs. 22.7% [10.3–40.1], p < 0.001) and consistently decreased in every patient with PAV+. Esophageal pressure–time product (PTPes) did not significantly differ between the two modes (107 cmH2O/s/min [79–131] under PSV vs. 149 cmH2O/s/min [129–170] under PAV+, p = 0.092), but the proportion of PTPes lost in ineffective triggering was significantly lower with PAV+ (2 cmH2O/s/min [1–6] vs. 8 cmH2O/s/min [3–30], p = 0.012). Conclusions Among patients with ineffective triggering under PSV, PSL adjustment failed to eliminate asynchrony in 58% of them (21 of 36 patients). In these patients with refractory ineffective triggering, switching from PSV to PAV+ significantly reduced or even suppressed the incidence of asynchrony.


2021 ◽  
Vol 3 ◽  
Author(s):  
Christophe Letellier ◽  
Manel Lujan ◽  
Jean-Michel Arnal ◽  
Annalisa Carlucci ◽  
Michelle Chatwin ◽  
...  

Background: Patient-ventilator synchronization during non-invasive ventilation (NIV) can be assessed by visual inspection of flow and pressure waveforms but it remains time consuming and there is a large inter-rater variability, even among expert physicians. SyncSmart™ software developed by Breas Medical (Mölnycke, Sweden) provides an automatic detection and scoring of patient-ventilator asynchrony to help physicians in their daily clinical practice. This study was designed to assess performance of the automatic scoring by the SyncSmart software using expert clinicians as a reference in patient with chronic respiratory failure receiving NIV.Methods: From nine patients, 20 min data sets were analyzed automatically by SyncSmart software and reviewed by nine expert physicians who were asked to score auto-triggering (AT), double-triggering (DT), and ineffective efforts (IE). The study procedure was similar to the one commonly used for validating the automatic sleep scoring technique. For each patient, the asynchrony index was computed by automatic scoring and each expert, respectively. Considering successively each expert scoring as a reference, sensitivity, specificity, positive predictive value (PPV), κ-coefficients, and agreement were calculated.Results: The asynchrony index assessed by SynSmart was not significantly different from the one assessed by the experts (18.9 ± 17.7 vs. 12.8 ± 9.4, p = 0.19). When compared to an expert, the sensitivity and specificity provided by SyncSmart for DT, AT, and IE were significantly greater than those provided by an expert when compared to another expert.Conclusions:SyncSmart software is able to score asynchrony events within the inter-rater variability. When the breathing frequency is not too high (&lt;24), it therefore provides a reliable assessment of patient-ventilator asynchrony; AT is over detected otherwise.


2021 ◽  
Vol 15 (1) ◽  
Author(s):  
Samiaa H. Sadek ◽  
Maha M. El-kholy ◽  
Marwa S. Abdulmoez ◽  
Reham M. El-Morshedy

Abstract Background Patient-ventilator asynchrony is a common problem in mechanically ventilated patients. It is associated with adverse effects including increased work of breathing, patient discomfort, increased need for sedation, prolonged mechanical ventilation, weaning difficulties, and weaning failure. The purpose of the present was to describe patient-ventilator asynchrony and its impact on weaning outcomes in mechanically ventilated chronic obstructive pulmonary disease (COPD) patients. Results One hundred mechanically ventilated COPD patients were enrolled in this prospective study. Weaning failure (need of NIV or reintubation within 48 h) was noticed in 27 (27%) patients while 73 (73%) patients had successful weaning. Patients with failed weaning had significantly higher asynchrony index (A.I) and ineffective trigger index (ITI) in comparison with those with successful weaning (7.69 ± 3.71, 3.46 ± 2.59 versus 6.27 ± 3.14, 2.47 ± 2.08, respectively; P value< 0.04). Data were expressed as mean ± standard deviation. Conclusion High asynchrony index and high ineffective trigger index may be early predictors of weaning failure in mechanically ventilated COPD patients.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Xu-Ying Luo ◽  
Xuan He ◽  
Yi-Min Zhou ◽  
Yu-Mei Wang ◽  
Jing-Ran Chen ◽  
...  

Abstract Background Patient–ventilator asynchrony is common in mechanically ventilated patients and may be related to adverse outcomes. Few studies have reported the occurrence of asynchrony in brain-injured patients. We aimed to investigate the prevalence, type and severity of patient–ventilator asynchrony in mechanically ventilated patients with brain injury. Methods This prospective observational study enrolled acute brain-injured patients undergoing mechanical ventilation. Esophageal pressure monitoring was established after enrollment. Flow, airway pressure, and esophageal pressure–time waveforms were recorded for a 15-min interval, four times daily for 3 days, for visually detecting asynchrony by offline analysis. At the end of each dataset recording, the respiratory drive was determined by the airway occlusion maneuver. The asynchrony index was calculated to represent the severity. The relationship between the prevalence and the severity of asynchrony with ventilatory modes and settings, respiratory drive, and analgesia and sedation were determined. Association of severe patient–ventilator asynchrony, which was defined as an asynchrony index  ≥ 10%, with clinical outcomes was analyzed. Results In 100 enrolled patients, a total of 1076 15-min waveform datasets covering 330,292 breaths were collected, in which 70,156 (38%) asynchronous breaths were detected. Asynchrony occurred in 96% of patients with the median (interquartile range) asynchrony index of 12.4% (4.3%–26.4%). The most prevalent type was ineffective triggering. No significant difference was found in either prevalence or asynchrony index among different classifications of brain injury (p > 0.05). The prevalence of asynchrony was significantly lower during pressure control/assist ventilation than during other ventilatory modes (p < 0.05). Compared to the datasets without asynchrony, the airway occlusion pressure was significantly lower in datasets with ineffective triggering (p < 0.001). The asynchrony index was significantly higher during the combined use of opioids and sedatives (p < 0.001). Significantly longer duration of ventilation and hospital length of stay after the inclusion were found in patients with severe ineffective triggering (p < 0.05). Conclusions Patient–ventilator asynchrony is common in brain-injured patients. The most prevalent type is ineffective triggering and its severity is likely related to a long duration of ventilation and hospital stay. Prevalence and severity of asynchrony are associated with ventilatory modes, respiratory drive and analgesia/sedation strategy, suggesting treatment adjustment in this particular population. Trial registration The study has been registered on 4 July 2017 in ClinicalTrials.gov (NCT03212482) (https://clinicaltrials.gov/ct2/show/NCT03212482).


2018 ◽  
Vol 104 (3) ◽  
pp. F280-F284 ◽  
Author(s):  
Cornelia G de Waal ◽  
Ruud W van Leuteren ◽  
Frans H de Jongh ◽  
Anton H van Kaam ◽  
Gerard J Hutten

ObjectiveTo describe the incidence of patient-ventilator asynchrony and different types of asynchrony in preterm infants treated with non-synchronised nasal intermittent positive pressure ventilation (nIPPV).DesignAn observational study was conducted including preterm infants born with a gestational age (GA) less than 32 weeks treated with non-synchronised nIPPV. During 1 hour, spontaneous breathing was measured with transcutaneous electromyography of the diaphragm simultaneous with ventilator inflations. An asynchrony index (AI), a percentage of asynchronous breaths, was calculated and the incidence of different types of inspiratory and expiratory asynchrony were reported.ResultsTwenty-one preterm infants with a mean GA of 26.0±1.2 weeks were included in the study. The mean inspiratory AI was 68.3%±4.7% and the mean expiratory AI was 67.1%±7.3%. Out of 5044 comparisons of spontaneous inspirations and mechanical inflations, 45.3% of the mechanical inflations occurred late, 23.3% of the mechanical inflations were early and 31.4% of the mechanical inflation were synchronous. 40.3% of 5127 expiratory comparisons showed an early termination of ventilator inflations, 26.7% of the mechanical inflations terminated late and 33.0% mechanical inflations terminated in synchrony with a spontaneous expiration. In addition, 1380 spontaneous breaths were unsupported and 611 extra mechanical inflations were delivered.ConclusionNon-synchronised nIPPV results in high patient-ventilator asynchrony in preterm infants during both the inspiratory and expiratory phase of the breathing cycle. New synchronisation techniques are urgently needed and should address both inspiratory and expiratory asynchrony.