magnetic coil
Recently Published Documents


TOTAL DOCUMENTS

134
(FIVE YEARS 24)

H-INDEX

25
(FIVE YEARS 2)

2021 ◽  
Author(s):  
Matthew Smith ◽  
Daniel Sievenpiper

<p>· We propose multi-loci and multi-site current patterning (sequential or simultaneous) for precise, rapid and repeatable steering for improved neuronal targeting.</p><p>· Here we demonstrate these improvements by using a unique pixel cell for excitation synthesis as enabled by a three-layer dense magnetic coil array that is mapped to a hexagonal grid with cubic coordinates.</p><p>· We validate the theory with supporting simulations, experimental results and a scalable electronics design that can address a relevant range of larger coil diameters, higher power levels and topologies.</p><p><a></a></p><p>· Precise, rapid and repeatable patterns potentially offer new modalities for noninvasive neuromodulation (suprathreshold and subthreshold) and adjacent biomagnetic applications such as tumor cell membrane disruption [1], and magnetic drug delivery [2].</p>


2021 ◽  
Author(s):  
Matthew Smith ◽  
Daniel Sievenpiper

<p>· We propose multi-loci and multi-site current patterning (sequential or simultaneous) for precise, rapid and repeatable steering for improved neuronal targeting.</p><p>· Here we demonstrate these improvements by using a unique pixel cell for excitation synthesis as enabled by a three-layer dense magnetic coil array that is mapped to a hexagonal grid with cubic coordinates.</p><p>· We validate the theory with supporting simulations, experimental results and a scalable electronics design that can address a relevant range of larger coil diameters, higher power levels and topologies.</p><p><a></a></p><p>· Precise, rapid and repeatable patterns potentially offer new modalities for noninvasive neuromodulation (suprathreshold and subthreshold) and adjacent biomagnetic applications such as tumor cell membrane disruption [1], and magnetic drug delivery [2].</p>


2021 ◽  
Vol 92 (9) ◽  
pp. 093202
Author(s):  
A. Kell ◽  
M. Link ◽  
M. Breyer ◽  
A. Hoffmann ◽  
M. Köhl ◽  
...  

2021 ◽  
Vol 11 (17) ◽  
pp. 7794
Author(s):  
Hak-Sun Lee ◽  
Sang-Gyun Park ◽  
Myoung-Pyo Hong ◽  
Han-Jin Lee ◽  
Young-Suk Kim

Most solenoid valves in use today require a magnetic coil to be continuously energized to maintain the magnetization of the magnetic body in order to operate. The problem is that if the power is still supplied, the power consumption will continue. In addition, problems such as shortening the lifespan of solenoid valve internal parts due to the increase in the internal temperature of the electronic stability control (ESC) due to the continuous heating of the magnetic coil, and malfunction due to instantaneous power failure may occur. In this study, we conducted a study on the permanent magnet traction control valve (TCV) for ESC that can minimize the unnecessary power consumption of electric vehicle batteries. For optimal permanent magnet design, polarity direction setting and permanent magnet specifications were studied through FE simulation. A permanent magnet TCV was fabricated and an electromagnetic force test was conducted to compare and evaluate it with the FE simulation result. By using a permanent magnet, it was possible to lower the initial current value for the TCV to drive, therefore, it was possible to develop a permanent magnet TCV that can minimize the unnecessary power consumption of electric vehicle batteries.


2021 ◽  
Vol 1845 (1) ◽  
pp. 012008
Author(s):  
B Winarno ◽  
Z J Paracha ◽  
M F Subkhan ◽  
R J Kusumo ◽  
T Lestariningsih ◽  
...  

2021 ◽  
Vol 16 (0) ◽  
pp. 2401020-2401020
Author(s):  
Taichi SEKI ◽  
Tomohiko ASAI ◽  
Daichi KOBAYASHI ◽  
Ryotaro YANAGI ◽  
Hiroshi GOTA ◽  
...  
Keyword(s):  

2021 ◽  
Vol 70 ◽  
pp. 1-9
Author(s):  
Kristin N. Hageman ◽  
Margaret R. Chow ◽  
Dale C. Roberts ◽  
Charles C. Della Santina

2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Jordan Skach ◽  
Catherine Conway ◽  
Lauryn Barrett ◽  
Hui Ye

Abstract Numerous neurological dysfunctions are characterized by undesirable nerve activity. By providing reversible nerve blockage, electric stimulation with an implanted electrode holds promise in the treatment of these conditions. However, there are several limitations to its application, including poor bio-compatibility and decreased efficacy during chronic implantation. A magnetic coil of miniature size can mitigate some of these problems, by coating it with biocompatible material for chronic implantation. However, it is unknown if miniature coils could be effective in axonal blockage and, if so, what the underlying mechanisms are. Here we demonstrate that a submillimeter magnetic coil can reversibly block action potentials in the unmyelinated axons from the marine mollusk Aplysia californica. Using a multi-compartment model of the Aplysia axon, we demonstrate that the miniature coil causes a significant local depolarization in the axon, alters activation dynamics of the sodium channels, and prevents the traveling of the invading action potentials. With improved biocompatibility and capability of emitting high-frequency stimuli, micro coils provide an interesting alternative for electric blockage of axonal conductance in clinical settings.


Sign in / Sign up

Export Citation Format

Share Document