tracking devices
Recently Published Documents


TOTAL DOCUMENTS

399
(FIVE YEARS 162)

H-INDEX

22
(FIVE YEARS 5)

Author(s):  
K. İleri ◽  
A. Duru ◽  
İ. R. Karaş

Abstract. Alzheimer’s is a degenerative disease meaning that it gets worse with time. Memory loss, speaking problems, wandering, and getting lost are some of the signs of the disease. The risk of wandering results in high demand for extensive monitoring solutions for the patients suffering from the disease. Tracking solutions are crucial, especially for family members and caregivers, so researchers develop new wearable tracking devices to overcome missing patients. GPS technology can provide location data with high accuracy, but it is not sufficient to use only by itself. Thus, a more extensive solution should be provided. In this paper, a mobile wearable tracking device that can provide data to the mobile application through internet has been developed for patient tracking purposes.


2021 ◽  
Author(s):  
Theresa Schweizer ◽  
Thomas Wyss ◽  
Rahel Gilgen-Ammann

ABSTRACT Introduction Objectively determining soldiers’ fatigue levels could help prevent injuries or accidents resulting from inattention or decreased alertness. Eye-tracking technologies, such as optical eye tracking (OET) and electrooculography (EOG), are often used to monitor fatigue. Eyeblinks—especially blink frequency and blink duration—are known as easily observable and valid biomarkers of fatigue. Currently, various eye trackers (i.e., eye-tracking glasses) are available on the market using either OET or EOG technologies. These wearable eye trackers offer several advantages, including unobtrusive functionality, practicality, and low costs. However, several challenges and limitations must be considered when implementing these technologies in the field to monitor fatigue levels. This review investigates the feasibility of eye tracking in the field focusing on the practical applications in military operational environments. Materials and Method This paper summarizes the existing literature about eyeblink dynamics and available wearable eye-tracking technologies, exposing challenges and limitations, as well as discussing practical recommendations on how to improve the feasibility of eye tracking in the field. Results So far, no eye-tracking glasses can be recommended for use in a demanding work environment. First, eyeblink dynamics are influenced by multiple factors; therefore, environments, situations, and individual behavior must be taken into account. Second, the glasses’ placement, sunlight, facial or body movements, vibrations, and sweat can drastically decrease measurement accuracy. The placement of the eye cameras for the OET and the placement of the electrodes for the EOG must be chosen consciously, the sampling rate must be minimal 200 Hz, and software and hardware must be robust to resist any factors influencing eye tracking. Conclusion Monitoring physiological and psychological readiness of soldiers, as well as other civil professionals that face higher risks when their attention is impaired or reduced, is necessary. However, improvements to eye-tracking devices’ hardware, calibration method, sampling rate, and algorithm are needed in order to accurately monitor fatigue levels in the field.


2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Christopher Ull ◽  
Uwe Hamsen ◽  
Christina Weckwerth ◽  
Thomas Armin Schildhauer ◽  
Robert Gaschler ◽  
...  

Sensors ◽  
2021 ◽  
Vol 21 (24) ◽  
pp. 8186
Author(s):  
Peter Beshara ◽  
David B. Anderson ◽  
Matthew Pelletier ◽  
William R. Walsh

Advancements in motion sensing technology can potentially allow clinicians to make more accurate range-of-motion (ROM) measurements and informed decisions regarding patient management. The aim of this study was to systematically review and appraise the literature on the reliability of the Kinect, inertial sensors, smartphone applications and digital inclinometers/goniometers to measure shoulder ROM. Eleven databases were screened (MEDLINE, EMBASE, EMCARE, CINAHL, SPORTSDiscus, Compendex, IEEE Xplore, Web of Science, Proquest Science and Technology, Scopus, and PubMed). The methodological quality of the studies was assessed using the consensus-based standards for the selection of health Measurement Instruments (COSMIN) checklist. Reliability assessment used intra-class correlation coefficients (ICCs) and the criteria from Swinkels et al. (2005). Thirty-two studies were included. A total of 24 studies scored “adequate” and 2 scored “very good” for the reliability standards. Only one study scored “very good” and just over half of the studies (18/32) scored “adequate” for the measurement error standards. Good intra-rater reliability (ICC > 0.85) and inter-rater reliability (ICC > 0.80) was demonstrated with the Kinect, smartphone applications and digital inclinometers. Overall, the Kinect and ambulatory sensor-based human motion tracking devices demonstrate moderate–good levels of intra- and inter-rater reliability to measure shoulder ROM. Future reliability studies should focus on improving study design with larger sample sizes and recommended time intervals between repeated measurements.


Sensors ◽  
2021 ◽  
Vol 21 (23) ◽  
pp. 7826
Author(s):  
Majdi K. Qabalin ◽  
Muawya Naser ◽  
Wafa M. Hawajreh ◽  
Saja Abu-Zaideh

Global Positioning System (GPS) is a global navigation satellite system and the most common satellite system used in navigation and tracking devices. The phenomenon of week number rollover happened recently—a year ago—due to a design limitation in the week number variable that counting weeks which causes vast losses. As many fleet management systems depend on GPS raw data, such systems stopped working due to inaccurate data provided by GPS receivers. In this paper, we propose a technical and mathematical analysis for the GPS week number rollover phenomenon and suggest a solution to avoid the resulting damage to other subsystems that depend on the GPS device’s raw data. In addition, this paper seeks to provide precautionary measures to deal with the problem proactively. The Open Systems Interconnection model (OSI) and transport layer level solution that has been suggested depends on a TCP packet reforming tool that re-formats the value of the week number according to a mathematical model based on a timestamp complement. At the level of the database, a solution is also suggested which uses triggers. A hardware-level solution is suggested by applying a timestamp complement over the GPS internal controller. Complete testing is applied for all suggested solutions using actual data provided by Traklink—a leading company in navigation and fleet management solutions. After testing, it is evident that the transport layer level solution was the most effective in terms of speed, efficiency, accuracy, cost, and complexity. Applying a transport layer level complement mathematical model can fix the consequences of GPS week number rollover and provide stability to all subsystems that used GPS data from infected devices.


Animals ◽  
2021 ◽  
Vol 11 (11) ◽  
pp. 3299
Author(s):  
Ulrika A. Bergvall ◽  
Nicolas Morellet ◽  
Petter Kjellander ◽  
Geir R. Rauset ◽  
Johannes De Groeve ◽  
...  

The fitting of tracking devices to wild animals requires capture and handling which causes stress and can potentially cause injury, behavioural modifications that can affect animal welfare and the output of research. We evaluated post capture and release ranging behaviour responses of roe deer (Capreolus capreolus) for five different capture methods. We analysed the distance from the centre of gravity and between successive locations, using data from 14 different study sites within the EURODEER collaborative project. Independently of the capture method, we observed a shorter distance between successive locations and contextual shift away from the home range centre of gravity after the capture and release event. However, individuals converged towards the average behaviour within a relatively short space of time (between 10 days and one month). If researchers investigate questions based on the distance between successive locations of the home range, we recommend (1) initial investigation to establish when the animals start to behave normally again or (2) not using the first two to three weeks of data for their analysis. We also encourage researchers to continually adapt methods to minimize stress and prioritize animal welfare wherever possible, according to the Refinement of the Three R’s.


Author(s):  
Alexandru-Viorel Palacean ◽  
Dumitru-Cristian Tranca ◽  
Cristian Contasel ◽  
Razvan Tataroiu ◽  
Cristian Dutescu
Keyword(s):  

Sensors ◽  
2021 ◽  
Vol 21 (21) ◽  
pp. 7255
Author(s):  
Guglielmo Pillitteri ◽  
Ewan Thomas ◽  
Giuseppe Battaglia ◽  
Giovanni Angelo Navarra ◽  
Antonino Scardina ◽  
...  

Electronic performance tracking devices are largely employed in team sports to monitor performance and improve training. To date, global positioning system (GPS) based devices are those mainly used in soccer training. The aim of this study was to analyse the validity and reliability of the inertial sensor device (ISD) in monitoring distance and speed in a soccer-specific circuit and how their performance compare to a GPS system. 44 young male soccer players (age: 14.9 ± 1.1, range 9–16, years, height: 1.65 ± 0.10 m, body mass: 56.3 ± 8.9 kg) playing in a non-professional soccer team in Italy, participated in the study. We assessed the players trough a soccer running sport-specific circuit. An ISD and a GPS were used to assess distance and speed. Data was compared to a video reference system, and the difference were quantified by means of the root mean square error (RMSE). Significant differences were found for both GPS and ISD devices for distance and speed. However, lower error for distance (dRMSE 2.23 ± 1.01 m and 5.75 ± 1.50 m, respectively) and speed (sRMSE 0.588 ± 0.152 m·s–1 and 1.30 ± 0.422 m·s–1, respectively) were attained by the ISD compared to the GPS. Overall, our results revealed a statistically significant difference between systems in data monitoring for either distance and speed. However, results of this study showed that a smaller error was obtained with the ISD than the GPS device. Despite caution is warranted within the interpretation of these results, we observed a better practical applicability of the ISD due to its small size, lower cost and the possibility to use the device indoor.


Sign in / Sign up

Export Citation Format

Share Document