concrete resistivity
Recently Published Documents


TOTAL DOCUMENTS

68
(FIVE YEARS 16)

H-INDEX

14
(FIVE YEARS 1)

2021 ◽  
Author(s):  
Aman Kumar ◽  
Jasvir Singh Rattan ◽  
Nishant Raj Kapoor ◽  
Ajay Kumar ◽  
Rahul Kumar

Sustainable development means the utilization of resources at a rate less than the rate at which they are renewing. In India infrastructure industry is growing rapidly due to globalization and raising awareness. In the present study, challenges faced by countries like India are to sustain the existing expectations with limited resources available. Reinforced Concrete (RC) structure may suffer several types of defects that may jeopardize their service life. This chapter deals with condition assessment and repair of RCC (G+3) building situated at Northern part of the country. There are various techniques available for repair and rehabilitation of reinforced concrete structures. From a maintenance point of view, it is essential to take up the strength assessment of an existing structure. So, to find out the reason behind the deterioration of the concrete structures some of the NDT and partially destructive technique are used. The NDT tests conducted during this study are Rebound Hammer, Ultra-sonic Pulse Velocity, Concrete resistivity Meter, Ferro-scanning and Carbonation, etc. This chapter helps to explains, how identified the different parameters of distress building like strength, density, level of corrosion and amount of reinforcement. On basis of these results, apply a repair methodology to revert back the strength parameters of the buildings.


Sensors ◽  
2021 ◽  
Vol 21 (7) ◽  
pp. 2481
Author(s):  
Jose Enrique Ramón ◽  
Isabel Martínez ◽  
José Manuel Gandía-Romero ◽  
Juan Soto

The concrete electrical resistivity is a prominent parameter in structural health monitoring, since, along with corrosion potential, it provides relevant qualitative diagnosis of the reinforcement corrosion. This study proposes a simple expression to reliable determine resistivity from the concrete electrical resistance (RE) provided by the corrosion sensor of the Integrated Network of Sensors for Smart Corrosion Monitoring (INESSCOM) we have developed. The novelty here is that distinct from common resistivity sensors, the cell constants obtained by the proposed expression are intended to be valid for any sensor implementation scenario. This was ensured by studying most significant geometrical features of the sensor in a wide set of calibration solutions. This embedded-sensor approach is intended to be applicable for RE measurements obtained both using potential step voltammetry (PSV, used in the INESSCOM sensor for corrosion rate measurement) and alternating current methods. In this regard, we present a simple protocol to reliably determine RE, and therefore resistivity, from PSV measurements. It consists in adding a very short potentiostatic pulse to the original technique. In this way, we are able to easy monitor resistivity along with corrosion rate through a single sensor, an advantage which is not usual in structural health monitoring.


Sensors ◽  
2020 ◽  
Vol 20 (24) ◽  
pp. 7113
Author(s):  
Kevin Paolo V. Robles ◽  
Dong-Won Kim ◽  
Jurng-Jae Yee ◽  
Jin-Wook Lee ◽  
Seong-Hoon Kee

The main objectives of this research are to evaluate the effects of delamination defects on the measurement of electrical resistivity of reinforced concrete slabs through analytical and experimental studies in the laboratory, and to propose a practical guide for electrical resistivity measurements on concrete with delamination defects. First, a 3D finite element model was developed to simulate the variation of electric potential field in concrete over delamination defects with various depths and lateral sizes. Second, for experimental studies, two reinforced concrete slab specimens (1500 mm (width) by 1500 mm (length) by 300 mm (thickness)) with artificial delamination defects of various dimensions and depths were fabricated. Third, the electrical resistivity of concrete over delamination defects in the numerical simulation models and the two concrete slab specimens were evaluated by using a 4-point Wenner probe in accordance with AASHTO (American Association of State Highway and Transportation Office) T-358. It was demonstrated from analytical and experimental studies in this study that shallow (50 mm depth) and deep (250 mm depth) delamination defects resulted in higher and lower electrical resistivity (ER) values, respectively, as compared to measurements performed on solid concrete locations. Furthermore, the increase in size of shallow defects resulted in an increase in concrete resistivity, whereas the increase in sizes of deep delamination defects yielded opposite results. In addition, measurements done directly above the steel reinforcements significantly lowered ER values. Lastly, it was observed from experimental studies that the effect of delamination defects on the values of electrical resistivity decreases as the saturation level of concrete increases.


2020 ◽  
Vol 10 (18) ◽  
pp. 6272 ◽  
Author(s):  
In-Seok Yoon ◽  
Chun-Ho Chang

The resistivity of a concrete structure exposed to chloride ions indicates the risk of early corrosion damage, because a low resistivity is related to rapid chloride penetration and to a high corrosion rate. Concrete resistivity is a geometry-independent material property that describes the electrical resistance, which is the ratio between the applied voltage and resulting current in a unit cell. The current is carried by ions dissolved in the pore liquid. While some data exist on the relationship between the moisture content and electrical resistivity of concrete, very little research has been conducted to evaluate the effect of chloride on the conduction of electricity through carbonated and non-carbonated concrete. The purpose of this study is to examine the effect of chloride concentration on the surface electrical resistivity measurement of carbonated and non-carbonated concrete. Chloride concentration had influenced the resistivity of concrete and the relationship showed a linear function. However, for concrete under the combined deterioration of carbonation and chlorides, a reduction in porosity due to the carbonation had a greater effect on the electrical resistivity than the increase in conductivity due to the chloride ions. Conclusively, this paper suggested the quantitative solution to depict the electrical resistivity of concrete with various chloride concentrations.


2020 ◽  
Vol 62 (1) ◽  
pp. 41-61
Author(s):  
Hornbostel Karla ◽  
Tobias Danner ◽  
Mette Rica Geiker

AbstractSeveral inspection methods can be used to assess the corrosion state of steel reinforcement in concrete. Especially for periodical field surveys and monitoring, non-destructive testing (NDT) methods are to be preferred as they do not cause any or very limited damage to the existing concrete. In this paper, the corrosion state of three reinforced concrete beams exposed to marine environment for 25 years was evaluated by measuring three parameters; electrochemical potential, concrete resistivity and corrosion rate. The measurements were performed with commercial devices. It was found that all devices are applicable for field inspections. Among the methods selected for the study, the electrochemical potential measured in a fine grid and analysed statistically offered the best possibility of evaluating the corrosion state; preferably in combination with selected excavations for determination of the level of corrosion.


2020 ◽  
Author(s):  
Udaya B. Halabe ◽  
Jonas Kavi ◽  
Hota V. S. GangaRao

This paper presents the use of an innovative low cost sensor for monitoring corrosion of steel membersembedded in concrete. Corrosion of steel reinforcing bars or embedded steel in concrete structuralcomponents is a major concern for structures such as bridges and parking garages. Moisture andchloride ingress through the cracks is the primary reason for corrosion of such concrete structures. Thechloride and moisture levels significantly affect the electrical conductivity of concrete. A low cost sensorfor measuring concrete resistivity (or conductivity) was developed by researchers at West VirginiaUniversity. This sensor is very durable and can be embedded in concrete members (beams, columns,etc.) at the time of pouring concrete. The electrical resistivity measurement obtained using this sensorcan be used to evaluate the potential for corrosion of embedded steel. This paper presents laboratoryand field results obtained using the sensor to demonstrate its usefulness. The paper also highlights thesimplicity and ease of use of this sensor. In addition, the paper also discusses the use of acommercially available temperature/humidity sensor that can be used in conjunction with the electricalresistivity sensor for a comprehensive assessment of the potential for corrosion of steel embedded inconcrete.


2020 ◽  
Author(s):  
Karthick Thiyagarajan ◽  
Parikshit Acharya ◽  
Lasitha Piyathilaka ◽  
sarath kodagoda

Smart Sensing technologies can play an important role in the conditional assessment of concrete sewer pipe linings. In the long-term, the permeation of acids can deteriorate the pipe linings. Currently, there are no proven sensors available to non-invasively estimate the depth of acid permeation in real-time. The electrical resistivity measurement on the surface of the linings can indicate the sub-surface acid moisture conditions. In this study, we consider acid permeated linings as a two resistivity layer concrete sample, where the top resistivity layer is assumed to be acid permeated and the bottom resistivity layer indicates normal moisture conditions. Firstly, we modeled the sensor based on the four-probe Wenner method. The measurements of the developed model were compared with the previous studies for validation. Then, the sensor model was utilized to study the effects of electrode contact area, electrode spacing distance and two resistivity layered concrete on the apparent resistivity measurements. All the simulations were carried out by varying the thickness of top resistivity layer concrete. The simulation study indicated that the electrode contact area has very minimal effects on apparent resistivity measurements. Also, an increase in apparent resistivity measurements was observed when there is an increase in the distance of the electrode spacing. Further, a machine learning approach using Gaussian process regression modeling was formulated to estimate the depth of acid permeated layer


Sign in / Sign up

Export Citation Format

Share Document