analytical limit
Recently Published Documents


TOTAL DOCUMENTS

18
(FIVE YEARS 1)

H-INDEX

5
(FIVE YEARS 0)

Universe ◽  
2021 ◽  
Vol 7 (9) ◽  
pp. 346
Author(s):  
Felipe J. Llanes-Estrada

The flattening of spiral-galaxy rotation curves is unnatural in view of the expectations from Kepler’s third law and a central mass. It is interesting, however, that the radius-independence velocity is what one expects in one less dimension. In our three-dimensional space, the rotation curve is natural if, outside the galaxy’s center, the gravitational potential corresponds to that of a very prolate ellipsoid, filament, string, or otherwise cylindrical structure perpendicular to the galactic plane. While there is observational evidence (and numerical simulations) for filamentary structure at large scales, this has not been discussed at scales commensurable with galactic sizes. If, nevertheless, the hypothesis is tentatively adopted, the scaling exponent of the baryonic Tully–Fisher relation due to accretion of visible matter by the halo comes out to reasonably be 4. At a minimum, this analytical limit would suggest that simulations yielding prolate haloes would provide a better overall fit to small-scale galaxy data.



2020 ◽  
Author(s):  
John C. Bramley ◽  
Jason E. Waligorski ◽  
Colin L. Kremitzki ◽  
Mariel J. Liebeskind ◽  
Alex L. Yenkin ◽  
...  

AbstractDistributed “Point-of-Care” or “at-Home” testing is an important component for a complete suite of testing solutions. This manuscript describes the construction and operation of a platform technology designed to meet this need. The ongoing COVID-19 pandemic will be used as the proof-of-concept for the efficacy and deployment of this platform. The technology outlined consists of a one-pot, reverse-transcription loop-mediated isothermal amplification (RT-LAMP) chemistry coupled with a low-cost and user-assembled reader using saliva as input. This platform is readily adapted to a wide range of pathogens due to the genetic basis of the reaction. A complete guide to the construction of the reader as well as the production of the reaction chemistry are provided here. Additionally, analytical limit of detection data and the results from saliva testing of SARS-CoV-2, are presented. The platform technology outlined here demonstrates a rapid, distributed, molecular point-of-care solution for pathogen detection using crude sample input.



Author(s):  
L.J. Krüger ◽  
M. Gaeddert ◽  
L. Köppel ◽  
L. E. Brümmer ◽  
C. Gottschalk ◽  
...  

AbstractBackgroundReliable point-of-care (POC) diagnostics not requiring laboratory infrastructure could be a game changer in the COVID-19 pandemic, particularly in the Global South. We assessed performance, limit of detection and ease-of-use of three antigen-detecting, rapid POC tests (Ag-RDT) for SARS-CoV-2.MethodsThis prospective, multi-centre diagnostic accuracy study recruited participants suspected to have SARS-CoV-2 in Germany and the UK. Paired nasopharyngeal swabs (NP) or NP and/or oropharyngeal swabs (OP) were collected from participants (one for clinical RT-PCR and one for Ag-RDT). Performance of each of three Ag-RDTs was compared to RT-PCR overall, and according to predefined subcategories e.g. cycle threshold (CT)-value, days from symptoms onset, etc. In addition, limited verification of the analytical limit-of-detection (LOD) was determined. To understand the usability a System Usability Scale (SUS) questionnaire and ease-of-use (EoU) assessment were performed.ResultsBetween April 17th and August 25th, 2020, 2417 participants were enrolled, with 70 (3.0%) testing positive by RT-PCR. The best-performing test (SD Biosensor, Inc. STANDARD Q) was 76×6% (95% Confidence Interval (CI) 62×8-86×4) sensitive and 99×3% (CI 98×6-99×6) specific. A sub-analysis showed all samples with RT-PCR CT-values <25 were detectable by STANDARD Q. The test was considered easy-to-use (SUS 86/100) and suitable for POC. Bioeasy and Coris showed specificity of 93×1% (CI 91×0%-94×8%) and 95×8% (CI 93×4%-97×4%), respectively, not meeting the predefined target of ≥98%.ConclusionThere is large variability in performance of Ag-RDT with SD Biosensor showing promise. Given the usability at POC, this test is likely to have impact despite imperfect sensitivity; however further research and modelling are needed.



Energies ◽  
2020 ◽  
Vol 13 (15) ◽  
pp. 3853
Author(s):  
Fernando Cañizal ◽  
Jorge Castro ◽  
Jorge Cañizal ◽  
César Sagaseta

Plate anchors are a well-established solution for supporting the efforts of floating platforms for wind and marine renewable energies. The behavior of ultrathin rigid plate anchors buried in purely cohesive soils under undrained and plane-strain conditions is analyzed. As already known, a dimensional analysis shows that the pull-out capacity of the anchor may be expressed using a weightless break-out factor (Nc0) that only depends on the ratio between the depth and the anchor width (H/B). Using finite element analyses, tabulated values of the weightless break-out factor are provided in this paper and three different failure mechanisms are identified, namely very shallow (quasi-vertical), shallow or intermediate (semi-vertical), and deep (rotational). For very shallow failure mechanisms, the studied problem is completely equivalent to the trapdoor problem because immediate breakaway at the bottom part of the anchor is considered (vented conditions). The existing analytical solutions for the very shallow (Nc0 = 1.956 H/B) and deep cases (Nc = 3π + 2) using the slip-line method are reviewed and an analytical limit is proposed for the first time for the very shallow mechanism (H/B = 1.314). For shallow (intermediate) cases, the failure mechanism is identified and the angle of the main slip lines is numerically evaluated.



Geosciences ◽  
2020 ◽  
Vol 10 (8) ◽  
pp. 279
Author(s):  
Blanche Richer ◽  
Ali Saeidi ◽  
Maxime Boivin ◽  
Alain Rouleau

Sensitive clays are known for producing retrogressive landslides, also called spread or flowslides. The key characteristics associated with the occurrence of these landslides on a sensitive clay slope must be assessed, and the potential retrogressive distance must be evaluated. Common risk analysis methods include empirical methods for estimating the distance of potential retrogression, analytical limit equilibrium methods, numerical modelling methods using the strength reduction technique, and the integration of a progressive failure mechanism into numerical methods. Methods developed for zoning purposes in Norway and Quebec provide conservative results in most cases, even if they don’t cover the worst cases scenario. A flowslide can be partially analysed using analytical limit equilibrium methods and numerical methods having strength reduction factor tools. Numerical modelling of progressive failure mechanisms using numerical methods can define the critical parameters of spread-type landslides, such as critical unloading and the retrogression distance of the failure. Continuous improvements to the large-deformation numerical modeling approach allow its application to all types of sensitive clay landslides.



Bioanalysis ◽  
2018 ◽  
Vol 10 (15) ◽  
pp. 1229-1248 ◽  
Author(s):  
Max Hecht ◽  
Rūta Veigure ◽  
Lewis Couchman ◽  
Charlotte I S Barker ◽  
Joseph F Standing ◽  
...  


Author(s):  
A. A. Golovkov ◽  
E. I. Mozhaeva

The limiting characteristics of electrically small-sized loop antenna matching by means of non-Foster's negative inductance are studied. Various options for including negative inductance in frame antenna structure are considered. The analytical limit expression for the operating frequency band of the small-sized loop antenna with the inclusion of negative inductance in the gap of the conductor frame is obtained. It is shown that for practical implementation the most convenient is the scheme with the inclusion of negative inductance between the conducting plane and the free output of the frame. Such inclusion of negative inductance causes small loss in width of the working frequency band compared with the inclusion of this inductance in the gap of the frame conductive plane, but EMF induced in the frame is twice as large.  An integral expression is obtained for the maximum band matching of the small-sized loop antenna with the inclusion of negative inductance in grounded output, the integral in which is calculated numerically for various small-sized loop antenna quality factor and ratios between resonant frequency of the frame and operating frequency range. The results obtained are similar to Fano-Yula restriction for passive matching chains.



2018 ◽  
Vol 13 ◽  
pp. 1725-1730 ◽  
Author(s):  
Sameera Naib ◽  
Wim De Waele ◽  
Primož Štefane ◽  
Nenad Gubeljak ◽  
Stijn Hertelé


2018 ◽  
Vol 2018 ◽  
pp. 1-13 ◽  
Author(s):  
Ahmed Salim ◽  
Sung-Hwan Kim ◽  
Joong Yull Park ◽  
Sungjoon Lim

A microfluidic biosensor is proposed using a microwave substrate-integrated waveguide (SIW) cavity resonator. The main objectives of this noninvasive biosensor are to detect and analyze biomaterial using tiny liquid volumes (3 μL). The sensing mechanism of our proposed biosensor relies on the dielectric perturbation phenomenon of biomaterial under test, which causes a change in resonance frequency and return loss (amplitude). First, an SIW cavity is realized on a Rogers RT/Duroid 5870 substrate. Then, a microwell made from polydimethylsiloxane (PDMS) material is loaded on the SIW cavity to observe the perturbation phenomenon. The microwell is filled with phosphate-buffered saline (PBS) solution (reference biological medium). To demonstrate the sensing behavior, the fibroblast (FB) cells from the lungs of a human male subject are analyzed and one-port S-parameters are measured. The resonance frequency of the structure with FB cells is observed to be 13.48 GHz. The reproducibility and repeatability of our proposed biosensor are successfully demonstrated through full-wave simulations and measurements. The resonance frequency of the FB-loaded microwell showed a shift of 170 MHz and 20 MHz, when compared to those of empty and PBS-loaded microwells. Its analytical limit of detection is 213 cells/μL. Our proposed biosensor is noncontact and reliable. Furthermore, it is miniaturized, inexpensive, and fabricated using simple- and easy-design processes.





Sign in / Sign up

Export Citation Format

Share Document