steady state measurement
Recently Published Documents


TOTAL DOCUMENTS

45
(FIVE YEARS 1)

H-INDEX

14
(FIVE YEARS 0)

2018 ◽  
Vol 70 ◽  
pp. 02005
Author(s):  
Krzysztof Dutkowski ◽  
Jacek Jan Fiuk

This paper details an experimental study that was performed to investigate rheological properties of microencapsulated phase change slurry - mPCM (Micronal® DS 5039 X and ERGOLID EKO®- an aqueous solution of propylene glycol). Seven samples of mPCM slurry were prepared with different mass ratio of the Micronal® to the ERGOLID EKO®: 30:70, 40:60, 50:50, 60:40, 70:30, 80:20 and 90:10. The apparent viscosity-shear rate curves were obtained for spindle speed from 0.01 to 100 rpm (shear rate 0.0132 to 132.00 s-1 respectively). The steady state measurement of viscosity was carried out when the slurry reached constant temperatures, namely: 10.0; 15.0, 17.5, 20.0, 22.5, 25.0, 27.5, 30.0, 40.0 and 50.0°C. The apparent viscosity of slurries increases with the mPCM concentration in dispersion rises. Only the sample of 30% Micronal® may be considered as a Newtonian fluid within the test range. Increasing the shear rate ultimately causes apparent viscosity to decrease down to the Newtonian plateau, where it seems to be constant. The variation of the viscosity as a function of temperature and microcapsules concentration was accurately represented by a modified Vogel-Tamman-Fulcher equation at a mean absolute error (MAE) of 10.76%.


2017 ◽  
Vol 5 (28) ◽  
pp. 14881-14886 ◽  
Author(s):  
Qi Li ◽  
Yicheng Zhao ◽  
Rui Fu ◽  
Wenke Zhou ◽  
Yao Zhao ◽  
...  

Using a double-layer hole transport material configuration, perovskite solar cells sustain over 90% of their initial output after 10 h of steady-state measurement.


2016 ◽  
Vol 17 (10) ◽  
pp. 1108-1117 ◽  
Author(s):  
Byron Mason ◽  
William Bradley ◽  
Antonios Pezouvanis ◽  
Kambiz Ebrahimi

2014 ◽  
Vol 75 ◽  
pp. 9-16 ◽  
Author(s):  
Tyler J. Johnson ◽  
Jason S. Olfert ◽  
Ross Cabot ◽  
Conor Treacy ◽  
Caner U. Yurteri ◽  
...  

2012 ◽  
Vol 616-618 ◽  
pp. 2187-2191
Author(s):  
Fang Liu ◽  
Hai Bao

Steady-state measurement value is the calculation premise of state estimation. However, power grid operates more often under dynamic state in actual practice. Thus, applying measured data from SCADA in state estimation directly lead to the incorrect and inaccurate calculation result. Based on the premise of state estimation calculation, the online electrical measurements and sampling methods are analyzed, and the deviation between real electrical values and sampling data is calculated. The cooperation problem between SCADA data and state estimation is proved using MATLAB/Simulink Software.