COCu: A robust self‐regenerative hydrogel with applicability as both hydrated gel dressing and dry suture for seamless tissue fixation and repair

2021 ◽  
pp. 2102074
Author(s):  
Tian Hu ◽  
Chuncheung Chan ◽  
Min‐Zhao Lin ◽  
Huaitian Bu ◽  
Bin Liu ◽  
...  
Keyword(s):  
Author(s):  
Jorge Pecci Saavedra ◽  
Mark Connaughton ◽  
Juan José López ◽  
Alicia Brusco

The use of antibodies as labels for the localization of specific molecules in the nervous systan has been extensively applied in recent years. Both monoand polyclonal antibodies or antisera have been employed. The knowledge of the organization of neuronal connectivities, gliovascular relationships, glioneuronal relationships and other features of nerve tissue has greatly increased.A number of areas of the nervous systan have been analyzed in our laboratory, including the nuclei of the raphe system, the reticular formation, interpeduncular nucleus, substantia nigra, caudate nucleus, putamen, pallidum, spinal cord, pineal gland and others.From a technical point of view, a number of variables needed to be taken into account in order to obtain reliable and reproducible results. The design of the optimal conditions of tissue fixation, embedding, sectioning, dilution of antibodies, and adaptation of Sternberger PAP technique were sane of the parameters taken into account to optimize the results. It is critical that each step of the technique be defined for each particular case.


Author(s):  
Anthony S-Y Leong ◽  
David W Gove

Microwaves (MW) are electromagnetic waves which are commonly generated at a frequency of 2.45 GHz. When dipolar molecules such as water, the polar side chains of proteins and other molecules with an uneven distribution of electrical charge are exposed to such non-ionizing radiation, they oscillate through 180° at a rate of 2,450 million cycles/s. This rapid kinetic movement results in accelerated chemical reactions and produces instantaneous heat. MWs have recently been applied to a wide range of procedures for light microscopy. MWs generated by domestic ovens have been used as a primary method of tissue fixation, it has been applied to the various stages of tissue processing as well as to a wide variety of staining procedures. This use of MWs has not only resulted in drastic reductions in the time required for tissue fixation, processing and staining, but have also produced better cytologic images in cryostat sections, and more importantly, have resulted in better preservation of cellular antigens.


Author(s):  
Jana Steger ◽  
Isabella Patzke ◽  
Maximilian Berlet ◽  
Stefanie Ficht ◽  
Markus Eblenkamp ◽  
...  

Abstract Purpose The introduction of novel endoscopic instruments is essential to reduce trauma in visceral surgery. However, endoscopic device development is hampered by challenges in respecting the dimensional restrictions, due to the narrow access route, and by achieving adequate force transmission. As the overall goal of our research is the development of a patient adaptable, endoscopic anastomosis manipulator, biomechanical and size-related characterization of gastrointestinal organs are needed to determine technical requirements and thresholds to define functional design and load-compatible dimensioning of devices. Methods We built an experimental setup to measure colon tissue compression piercing forces. We tested 54 parameter sets, including variations of three tissue fixation configurations, three piercing body configurations (four, eight, twelve spikes) and insertion trajectories of constant velocities (5 mms−1, 10 mms−1,15 mms−1) and constant accelerations (5 mms−2, 10 mms−2, 15 mms−2) each in 5 samples. Furthermore, anatomical parameters (lumen diameter, tissue thickness) were recorded. Results There was no statistically significant difference in insertion forces neither between the trajectory groups, nor for variation of tissue fixation configurations. However, we observed a statistically significant increase in insertion forces for increasing number of spikes. The maximum mean peak forces for four, eight and twelve spikes were 6.4 ± 1.5 N, 13.6 ± 1.4 N and 21.7 ± 5.8 N, respectively. The 5th percentile of specimen lumen diameters and pierced tissue thickness were 24.1 mm and 2.8 mm, and the 95th percentiles 40.1 mm and 4.8 mm, respectively. Conclusion The setup enabled reliable biomechanical characterization of colon material, on the base of which design specifications for an endoscopic anastomosis device were derived. The axial implant closure unit must enable axial force transmission of at least 28 N (22 ± 6 N). Implant and applicator diameters must cover a range between 24 and 40 mm, and the implant gap, compressing anastomosed tissue, between 2 and 5 mm.


Biomolecules ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 889
Author(s):  
Pooja Lahiri ◽  
Suranjana Mukherjee ◽  
Biswajoy Ghosh ◽  
Debnath Das ◽  
Basudev Lahiri ◽  
...  

The choice of tissue fixation is critical for preserving the morphology and biochemical information of tissues. Fragile oral tissues with lower tensile strength are challenging to process for histological applications as they are prone to processing damage, such as tissue tear, wrinkling, and tissue fall-off from slides. This leads to loss of morphological information and unnecessary delay in experimentation. In this study, we have characterized the new PAXgene tissue fixation system on oral buccal mucosal tissue of cancerous and normal pathology for routine histological and immunohistochemical applications. We aimed to minimize the processing damage of tissues and improve the quality of histological experiments. We also examined the preservation of biomolecules by PAXgene fixation using FTIR microspectroscopy. Our results demonstrate that the PAXgene-fixed tissues showed significantly less tissue fall-off from slides. Hematoxylin and Eosin staining showed comparable morphology between formalin-fixed and PAXgene-fixed tissues. Good quality and slightly superior immunostaining for cancer-associated proteins p53 and CK5/6 were observed in PAXgene-fixed tissues without antigen retrieval than formalin-fixed tissues. Further, FTIR measurements revealed superior preservation of glycogen, fatty acids, and amide III protein secondary structures in PAXgene-fixed tissues. Overall, we present the first comprehensive evaluation of the PAXgene tissue fixation system in oral tissues. This study concludes that the PAXgene tissue fixation system can be applied to oral tissues to perform diagnostic molecular pathology experiments without compromising the quality of the morphology or biochemistry of biomolecules.


1996 ◽  
Vol 28 (5) ◽  
pp. 375-383 ◽  
Author(s):  
B. Durgun-Yücel ◽  
D. Hopwood ◽  
A. H. Yücel

1985 ◽  
Vol 55 (1) ◽  
pp. 194-198 ◽  
Author(s):  
Melvin M. Scheinman ◽  
Saroja Bharati ◽  
Yin-Shi Wang ◽  
William A. Shapiro ◽  
Maurice Lev

Sign in / Sign up

Export Citation Format

Share Document