scholarly journals Handheld Device for Selective Benzene Sensing over Toluene and Xylene

2021 ◽  
pp. 2103853
Author(s):  
Ines C. Weber ◽  
Pascal Rüedi ◽  
Petr Šot ◽  
Andreas T. Güntner ◽  
Sotiris E. Pratsinis
Keyword(s):  
2021 ◽  
Vol 51 (1) ◽  
pp. 10-15
Author(s):  
Kenneth V Iserson ◽  
Sri Devi Jagjit ◽  
Balram Doodnauth

Acute thoracic aortic dissection is an uncommon, although not rare, life-threatening condition. With protean signs and symptoms that often suggest more common cardiac or pulmonary conditions, it can be difficult to diagnose. Ultrasound has proven useful in making the correct diagnosis. This case demonstrates that training gained using standard ultrasound machines can be easily and successfully adapted to newer handheld ultrasound devices. The examination technique using the handheld device is illustrated with photos and a video.


2020 ◽  
Vol 98 (Supplement_4) ◽  
pp. 296-297
Author(s):  
Daniela M Meléndez ◽  
Sonia Marti ◽  
Luigi Faucitano ◽  
Derek B Haley ◽  
Timothy D Schwinghamer ◽  
...  

Abstract Blood metabolites are used to assess a variety of animal conditions for veterinary diagnosis and research. Concentration of metabolites in blood can be measured using a commercially-available lab-based assay or in real-time using a handheld device developed to be more time- and cost-effective than the lab-based method. Lactate is a product of anaerobic glycolysis, used in animal research as an indicator of muscle fatigue. Therefore, it has been used as an indicator of cattle response to long distance transportation. The aim of this study was to assess the relationship of L-lactate concentrations measured using a Lactate Scout+ analyzer (Lactate Scout, EFK Diagnostics, Barleben, Germany) and a lactate assay colorimetric kit (Lactate Assay Kit, Cell Biolabs Inc., San Diego, CA). Blood samples were collected by venipuncture from 96 steers (245 ± 35.7 kg BW) prior to (L1) and after 36 h, and prior to and after an additional 4 h of road transportation, and on d 1, 2, 3, 5, 14, and 28 after transport. The Lactate Scout+ analyzer strip was dipped in blood at the time of sampling, while blood samples were collected into sodium fluoride tubes for use in colorimetric analysis. Pearson correlations were calculated to determine the relationship between the experimental methods for the quantification of L-lactate concentrations. The strengths and levels of statistical significance of the correlation varied over the observed time points, r = -0.03, P = 0.75 (L1) to r = 0.75, P = < 0.0001 (d 3). The correlation for the pooled data was weak but statistically significant (r = 0.33, P < 0.001). Based on the experimental results, the Lactate Scout+ analyzer is not a suitable alternative to a lab-based assay for measuring L-lactate in transported cattle, due to variability across sampling time points and weak correlation with the traditional enzymatic method.


Author(s):  
Aram Radnia ◽  
Hamed Abdollahzadeh ◽  
Behnoosh Teimourian ◽  
Mohammad Hossein Farahani ◽  
Mohammad Esmaeil Akbari ◽  
...  

Abstract Background A gamma probe is a handheld device used for intraoperative interventions following interstitial injection of a radiotracer to locate regional lymph nodes through the external detection of radiation. This work reports on the design and performance evaluation of a novel fully integrated gamma probe (GammaPen), recently developed by our group. Materials and methods GammaPen is an all-in-one pocket gamma probe with low weight and adequate dimensions, consisting of a detector, a control unit and output all together. The detector module consists of a cylindrical Thallium-activated Cesium Iodide [CsI (Tl)] crystal optically coupled to a Silicon photomultiplier (SiPM), shielded using Tungsten housing on side and back faces. The electronics of the probe consists of two small boards to handle signal processing and analog peak detection tasks. A number of parameters, including probe sensitivity in air/water, spatial resolution in air/water, angular resolution in air/water, and side and back shielding effectiveness, were measured to evaluate the performance of the probe based on NEMA NU3-2004 standards. Results The sensitivity of the probe in air at distances of 10, 30, and 50 mm is 18784, 3500, and 1575 cps/MBq. The sensitivity in scattering medium was also measured at distances of 10, 30, and 50 mm as 17,680, 3050, and 1104 cps/MBq. The spatial and angular resolutions in scattering medium were 47 mm and 87 degree at 30 mm distance from the probe, while they were 40 mm and 77 degree in air. The detector shielding effectiveness and leakage sensitivity are 99.91% and 0.09%, respectively. Conclusion The performance characterization showed that GammaPen can be used effectively for sentinel lymph node localization. The probe was successfully used in several surgical interventions by an experienced surgeon confirming its suitability in a clinical setting.


Sensors ◽  
2020 ◽  
Vol 21 (1) ◽  
pp. 15
Author(s):  
Filippo Aleotti ◽  
Giulio Zaccaroni ◽  
Luca Bartolomei ◽  
Matteo Poggi ◽  
Fabio Tosi ◽  
...  

Depth perception is paramount for tackling real-world problems, ranging from autonomous driving to consumer applications. For the latter, depth estimation from a single image would represent the most versatile solution since a standard camera is available on almost any handheld device. Nonetheless, two main issues limit the practical deployment of monocular depth estimation methods on such devices: (i) the low reliability when deployed in the wild and (ii) the resources needed to achieve real-time performance, often not compatible with low-power embedded systems. Therefore, in this paper, we deeply investigate all these issues, showing how they are both addressable by adopting appropriate network design and training strategies. Moreover, we also outline how to map the resulting networks on handheld devices to achieve real-time performance. Our thorough evaluation highlights the ability of such fast networks to generalize well to new environments, a crucial feature required to tackle the extremely varied contexts faced in real applications. Indeed, to further support this evidence, we report experimental results concerning real-time, depth-aware augmented reality and image blurring with smartphones in the wild.


Foods ◽  
2021 ◽  
Vol 10 (5) ◽  
pp. 1042
Author(s):  
Silvia Grassi ◽  
Olusola Samuel Jolayemi ◽  
Valentina Giovenzana ◽  
Alessio Tugnolo ◽  
Giacomo Squeo ◽  
...  

Poorly emphasized aspects for a sustainable olive oil system are chemical analysis replacement and quality design of the final product. In this context, near infrared spectroscopy (NIRS) can play a pivotal role. Thus, this study aims at comparing performances of different NIRS systems for the prediction of moisture, oil content, soluble solids, total phenolic content, and antioxidant activity of intact olive drupes. The results obtained by a Fourier transform (FT)-NIR spectrometer, equipped with both an integrating sphere and a fiber optic probe, and a Vis/NIR handheld device are discussed. Almost all the partial least squares regression models were encouraging in predicting the quality parameters (0.64 < R2pred < 0.84), with small and comparable biases (p > 0.05). The pair-wise comparison between the standard deviations demonstrated that the FT-NIR models were always similar except for moisture (p < 0.05), whereas a slightly lower performance of the Vis/NIR models was assessed. Summarizing, while on-line or in-line applications of the FT-NIR optical probe should be promoted in oil mills in order to quickly classify the drupes for a better quality design of the olive oil, the portable and cheaper Vis/NIR device could be useful for preliminary quality evaluation of olive drupes directly in the field.


2012 ◽  
Vol 134 (1) ◽  
Author(s):  
Zhi Huang ◽  
Xinsheng Zhang ◽  
Ming Zhou ◽  
Xiaoding Xu ◽  
Xianzheng Zhang ◽  
...  

Increasing functionality demands more heat dissipation from the skin of handheld devices. The maximum amount of heat that can be dissipated passively, prescribed by the natural convection and blackbody radiation theories, is becoming the bottleneck. In this letter, we propose a novel bio-inspirited technique that may overcome this passive cooling limit. It is made possible by using a biomimetic skin capable of perspiration on demand. The key component of the biomimetic skin is a thin layer of temperature sensitive hydro gel (TSHG). The TSHG layer can sweat the skin with moisture when the skin temperature is higher than the TSHG’s lower critical solution temperature (LCST), and thus boost the heat dissipation rate through evaporation. The TSHG layer can absorb moisture at low temperature to replenish. With this novel passive cooling technology, a handheld device can have nearly four times more power beyond the traditional passive cooling limit, and may be powerful enough to run a desktop operation system like a full functional personal computer.


Sign in / Sign up

Export Citation Format

Share Document