Development of a PVC Membrane Potentiometric Sensor with Low Detection Limit and Wide Linear Range for the Determination of Maprotiline in Pharmaceutical Formulations

2022 ◽  
Vol 7 (2) ◽  
Author(s):  
Serkan Tekce ◽  
Yaver Subasi ◽  
Fatih Coldur ◽  
Gulsah Saydan Kanberoglu ◽  
Mehmet Zahmakiran
2018 ◽  
Vol 54 (98) ◽  
pp. 13782-13785 ◽  
Author(s):  
Yu Liu ◽  
Yonggang Ding ◽  
Ying Gao ◽  
Rui Liu ◽  
Xiaorong Hu ◽  
...  

The metal stable isotope detection strategy demonstrates a wide linear range and a low detection limit, showing promising potential in clinical diagnosis.


2015 ◽  
Vol 39 (7) ◽  
pp. 5522-5528 ◽  
Author(s):  
Lihui Tian ◽  
Lei Liu ◽  
Yueyuan Li ◽  
Qin Wei ◽  
Wei Cao

A signal amplifying sandwich-type immunosensor with a wide linear range and a low detection limit is developed with potential clinical and diagnostic applications.


2015 ◽  
Vol 15 (11) ◽  
pp. 6199-6207 ◽  
Author(s):  
Gulsah Saydan Kanberoglu ◽  
Fatih Coldur ◽  
Cihan Topcu ◽  
Osman Cubuk

RSC Advances ◽  
2015 ◽  
Vol 5 (23) ◽  
pp. 17372-17378 ◽  
Author(s):  
Chao Liu ◽  
Jiansheng Li ◽  
Jing Wang ◽  
Junwen Qi ◽  
Wenhong Fan ◽  
...  

A novel nonenzymatic H2O2 sensor is fabricated based on Ag@SiO2 yolk–shell nanoparticles (YSNs) via a sequential impregnation–reduction approach. These exhibit outstanding H2O2 reduction, with a fast amperometric response, a low detection limit and a wide linear range.


2016 ◽  
Vol 8 (24) ◽  
pp. 4912-4918 ◽  
Author(s):  
Pengfei Pang ◽  
Fuqing Yan ◽  
Haizhen Li ◽  
Haiyan Li ◽  
Yanli Zhang ◽  
...  

A graphene quantum dots-Nafion composite as a novel electrode material was developed for ultrasensitive detection of dopamine with a low detection limit of 0.45 nM and a wide linear range of 5 nM to 100 μM.


2020 ◽  
Vol 21 (8) ◽  
pp. 2853 ◽  
Author(s):  
Veerappan Mani ◽  
T.S.T. Balamurugan ◽  
Sheng-Tung Huang

Designing and engineering nanocomposites with tailored physiochemical properties through teaming distinct components is a straightforward strategy to yield multifunctional materials. Here, we describe a rapid, economical, and green one-pot microwave synthetic procedure for the preparation of ternary nanocomposites carbon/polydopamine/Au nanoparticles (C/PDA/AuNPs; C = carbon nanotubes (CNTs), reduced graphene oxide (rGO)). No harsh reaction conditions were used in the method, as are used in conventional hydrothermal or high-temperature methods. The PDA unit acts as a non-covalent functionalizing agent for carbon, through π stacking interactions, and also as a stabilizing agent for the formation of AuNPs. The CNTs/PDA/AuNPs modified electrode exhibited excellent electrocatalytic activity to oxidize chloramphenicol and the resulting sensor exhibited a low detection limit (36 nM), wide linear range (0.1–534 μM), good selectivity (against 5-fold excess levels of interferences), appreciable reproducibility (3.47%), good stability (94.7%), and practicality (recoveries 95.0%–98.4%). Likewise, rGO/PDA/AuNPs was used to fabricate a sensitive folic acid sensor, which exhibits excellent analytical parameters, including wide linear range (0.1–905 μM) and low detection limit (25 nM). The described synthetic route includes fast reaction time (5 min) and a readily available household microwave heating device, which has the potential to significantly contribute to the current state of the field.


2019 ◽  
Vol >15 (5) ◽  
pp. 492-500
Author(s):  
Lizhai Pei ◽  
Fanglv Qiu ◽  
Yue Ma ◽  
Feifei Lin ◽  
Chuangang Fan ◽  
...  

Background: Formaldehyde belongs to important pollutant and is usually found in liquid environment, such as juices, beer, cleaning products and biological fluid of the human. The electrochemical sensors using glassy carbon electrode (GCE) modified with polyaniline/Zn bismuthate nanocomposites can effectively detect formaldehyde with broad linear range and good reproducibility. Methods: Polyaniline/Zn bismuthate nanocomposites were prepared by in-situ aniline polymerizing route in aqueous solution. The structure and morphologies of the nanocomposites were analyzed by X-ray diffraction (XRD) and transmission electron microscopy. The electrochemical performance for formaldehyde detection has been investigated by cyclic voltammetry (CV) method using polyaniline/ Zn bismuthate nanocomposites modified GCE. Results: XRD shows that ZnBi38O58 phase exists in the nanocomposites. Amorphous polyaniline attaches to the surface of the Zn bismuthate nanorods. The 20wt.% polyaniline/Zn bismuthate nanocomposites modified GCE shows an irreversible cyclic voltammetry (CV) peak at –0.06 V. The peak current increases sharply with increased scan rate, formaldehyde concentration and acidity. The electrochemical response dependences including the linear range, detection limit were analyzed. 20wt.% polyaniline/Zn bismuthate nanocomposites modified GCE shows low detection limit of 0.0095 µM and wide linear range of 0.00001-2 mM. The detection limit for formaldehyde decreases from 0.028 µM to 0.0075 µM with the increase in the polyaniline content from 10wt.% to 40wt.%. Conclusion: The low detection limit and wide linear range make the nanocomposites modified GCE valuable for sensor application. Polyaniline/Zn bismuthate nanocomposites are identified as the prominent electrode materials for sensitive formaldehyde detection.


RSC Advances ◽  
2016 ◽  
Vol 6 (109) ◽  
pp. 107851-107858 ◽  
Author(s):  
Cui'e Zou ◽  
Duan Bin ◽  
Beibei Yang ◽  
Ke Zhang ◽  
Yukou Du

The novel Au–Ag nanorings/NG modified electrode was found to have a wide linear range from 0.05 μM to 241.2 μM (S/N = 3) with a low detection limit of 0.01 μM when it was employed for rutin detection.


2017 ◽  
Vol 9 (1) ◽  
pp. 134-140 ◽  
Author(s):  
Jinfeng Zou ◽  
Zhiguang Liu ◽  
Yujing Guo ◽  
Chuan Dong

A sensitive electrochemical sensor for Bisphenol A is developed based on TM-β-CD-Gr/PtNPs. This method has wide linear range and low detection limit. Moreover, it is convenient and cost-effective.


Sign in / Sign up

Export Citation Format

Share Document