Investigates the Impact of Insulation Material on the Building Performance in Different Weather Zones of India

Author(s):  
Shaheen Hasan ◽  
Sabah Khan ◽  
Saif Uddin
2016 ◽  
Vol 41 (2) ◽  
pp. 162-189
Author(s):  
Nolwenn Hurel ◽  
Mickaël Pailha ◽  
Géraldine Garnier ◽  
Monika Woloszyn

Poor airtightness in buildings can lead to an over-consumption of energy and to many issues such as moisture damage and poor indoor climate. The timber frame constructions are particularly subject to air leakages, and further knowledge in this field is needed to meet the regulation requirements tightened by the development of low-energy and passive houses. This article focuses on a three-scale experimental study carried out in laboratories to quantify the impact of a number of construction details on timber frame wall airtightness. For this purpose, we built two original experimental setups and to complement an existing large-scale facility. Each setup enables to carry out pressurization tests at a different scale. The results put all together give quantitative information for more accurate simulations of building performance. Some specific construction details were investigated. It has been found in particular that the density of the insulation material is significant since a soft glass wool can have an air permeability three times higher than a rigid one with the same thermal performances. Moreover, it has been pointed out that the bond between the gypsum board and the insulation has a significant impact on the resulting pressure–flow law, and to ensure that there is no air gap the whole interface should be glued. The air flow directions also influence the flow values for high-pressure differences. Finally, at wall scale we have found that the sealing of the gypsum boards and the vapor barrier against the bottom wall plate is not very significant as long as the exterior side is sealed correctly. On the other hand, a proper sealing on both sides of a window is required because of the air gaps along it.


2021 ◽  
Vol 6 (6) ◽  
pp. 79
Author(s):  
Nuno M. M. Ramos ◽  
Joana Maia ◽  
Andrea R. Souza ◽  
Ricardo M. S. F. Almeida ◽  
Luís Silva

Near-infrared (NIR) reflective materials are being developed for mitigating building cooling needs. Their use contributes to broadening the range of colours, responding to the urban aesthetic demand without compromising the building performance. Despite the increase in NIR reflective pigments investigation, there is still a knowledge gap in their applicability, impact, and durability in multilayer finishing coatings of External Thermal Insulation Composite Systems (ETICS). Hence, the main goal of this work consists of evaluating the impact of incorporating NIR reflective pigments (NRP) in the solar reflectance of the surface layer of ETICS, without affecting the colour perception, as well as their influence on the colour durability and surface temperature. As such, colour, solar reflectance, and surface temperature were monitored for 2 years in dark-coloured specimens of ETICS, with and without NRP and a primer layer. It was confirmed that the main contribution of NRP is the increase of solar reflectance and, consequently, the decrease in surface temperature, especially for high exterior temperatures (around 30 ºC). Moreover, these pigments highly increase the NIR reflectance without affecting the visible colour. In addition, they contribute to maintaining the colour characteristics. The application of primer increased the surface temperature, especially for higher exterior temperatures. However, it contributes to a lower colour difference and solar reflectance variation, which is an important achievement for durability purposes.


2021 ◽  
Vol 10 (1) ◽  
Author(s):  
Jun Yin ◽  
Lian Liu ◽  
Yashu Zang ◽  
Anni Ying ◽  
Wenjie Hui ◽  
...  

AbstractHere, an engineered tunneling layer enhanced photocurrent multiplication through the impact ionization effect was proposed and experimentally demonstrated on the graphene/silicon heterojunction photodetectors. With considering the suitable band structure of the insulation material and their special defect states, an atomic layer deposition (ALD) prepared wide-bandgap insulating (WBI) layer of AlN was introduced into the interface of graphene/silicon heterojunction. The promoted tunneling process from this designed structure demonstrated that can effectively help the impact ionization with photogain not only for the regular minority carriers from silicon, but also for the novel hot carries from graphene. As a result, significantly enhanced photocurrent as well as simultaneously decreased dark current about one order were accomplished in this graphene/insulation/silicon (GIS) heterojunction devices with the optimized AlN thickness of ~15 nm compared to the conventional graphene/silicon (GS) devices. Specifically, at the reverse bias of −10 V, a 3.96-A W−1 responsivity with the photogain of ~5.8 for the peak response under 850-nm light illumination, and a 1.03-A W−1 responsivity with ∼3.5 photogain under the 365 nm ultraviolet (UV) illumination were realized, which are even remarkably higher than those in GIS devices with either Al2O3 or the commonly employed SiO2 insulation layers. This work demonstrates a universal strategy to fabricate broadband, low-cost and high-performance photo-detecting devices towards the graphene-silicon optoelectronic integration.


2016 ◽  
Vol 52 (4) ◽  
pp. 2951-2960 ◽  
Author(s):  
Malgorzata Sumislawska ◽  
Konstantinos N. Gyftakis ◽  
Darren F. Kavanagh ◽  
Malcolm D. McCulloch ◽  
Keith J. Burnham ◽  
...  

2018 ◽  
Vol 163 ◽  
pp. 08004 ◽  
Author(s):  
Ewa Sudoł ◽  
Dawid Dębski ◽  
Renata Zamorowska ◽  
Barbara Francke

In the paper the results of an experimental program intended to determine factors influencing the impact resistance of the External Thermal Insulation Composite Systems (ETICS) were presented. For the research the systems based on polystyrene have been chosen. The insulation material was faced with a rendering consisting of base coat reinforced with standard or armored glass fibre mesh and silicone or silicone-silicate binders as finishing coats. The influence of various renderings components was evaluated with respect to resistance to hard body impact and resistance to hail. The test results were discussed in the context of the possible impact level on ETICS in use.


2020 ◽  
Vol 172 ◽  
pp. 09006
Author(s):  
Kamilla Heimar Andersen ◽  
Sverre B. Holøs ◽  
Aileen Yang ◽  
Kari Thunshelle ◽  
Øystein Fjellheim ◽  
...  

This study evaluates typical faults occurring in demand-controlled ventilation (DCV) system and the impact on three output results: energy use, thermal comfort, and indoor air quality. The methodologies used in this study were qualitative interviews of selected Norwegian Heating Ventilation Air Condition (HVAC) system experts and numerical modeling using the building performance simulation tool IDA ICE. The faults deduced from the qualitative interviews were modeled as the fault's different consequences to account for a large variety of faults. With a Norwegian school classroom as a case study, a local approach applying a one-at-a-time (OAT) simulation was used to perform an analysis of the extreme fault conditions that can occur. The results from the fault modeling demonstrated that greater attention is needed to avoid faults in the HVAC systems due to its impact on the indoor environment quality and energy efficiency of buildings.


Holzforschung ◽  
2018 ◽  
Vol 72 (8) ◽  
pp. 681-689 ◽  
Author(s):  
Mostafa Mohammadabadi ◽  
Vikram Yadama ◽  
LiHong Yao ◽  
Debes Bhattacharyya

AbstractProfiled hollow core sandwich panels (SPs) and their components (outer layers and core) were manufactured with ponderosa and lodgepole pine wood strands to determine the effects of low-velocity impact forces and to observe their energy absorption (EA) capacities and failure modes. An instrumented drop weight impact system was applied and the tests were performed by releasing the impact head from 500 mm for all the specimens while the impactors (IMPs) were equipped with hemispherical and flat head cylindrical heads. SPs with cavities filled with a rigid foam insulation material (SPfoam) were also tested to understand the change in EA behavior and failure mode. Failure modes induced by both IMPs to SPs were found to be splitting, perforating, penetrating, core crushing and debonding between the core and the outer layers. SPfoams absorbed 26% more energy than unfilled SPs. SPfoams with urethane foam suffer less severe failure modes than SPs. SPs in a ridge-loading configuration absorbed more impact energy than those in a valley-loading configuration, especially when impacted by a hemispherical IMP. Based on the results, it is evident that sandwich structure is more efficient than a solid panel concerning impact energy absorption, primarily due to a larger elastic section modulus of the core’s corrugated geometry.