Segregation of impurity elements in porous iron

1986 ◽  
Vol 25 (3) ◽  
pp. 254-258 ◽  
Author(s):  
I. D. Radomysel'skii ◽  
Yu. V. Mil'man ◽  
Yu. N. Ivashchenko ◽  
R. K. Ivashchenko ◽  
N. I. Shcherban' ◽  
...  
Author(s):  
D. A. Petrochenkov

Fossils of marine reptiles are a new jewelry and ornamental material and collected in the Ulyanovsk region from the Upper Jurassic deposits. They consist of (wt. %): calcite — 52, apatite — 24 and pyrite — 23, and also gypsum presents. The contents of radioactive and carcinogenic elements are close to background. The original bone structure of reptiles is preserved. Apatite replaces the bone tissue of marine reptiles, forming a cellular framework. According to the chemical composition, apatite refers to fluorohydroxyapatite with an increased Sr content. The size of the crystals is finely-dispersed. Calcite and pyrite fill the central parts of the cells. Calcite crystals of isometric and elongated shape, 0,01—0,05 mm in size, form blocks up to 0,3 mm during intergrowth. Calcite fills thin, discontinuous veins along the contour of cells with a width of up to 0,03 mm. In calcite, among the impurity elements, there are (wt. %, on the average): Mg — 0,30, Mn — 0,39 and Fe — 0,96. Pyrite forms a dispersed impregnation in calcite and apatite, content of impurities is, wt. %: Ni — up to 0,96 and Cu — up to 0,24. On technological and decorative characteristics of fossils of sea reptiles of Ulyanovsk region are qualitative jewelry and ornamental materials of biomineral group, allowing to make a wide assortment of jewelry and souvenir products.


2021 ◽  
Vol 127 (8) ◽  
Author(s):  
R. Radhakrishnan Sumathi

AbstractAluminium nitride (AlN) is a futuristic material for efficient next-generation high-power electronic and optoelectronic applications. Sublimation growth of AlN single crystals with hetero-epitaxial approach using silicon carbide substrates is one of the two prominent approaches emerged, since the pioneering crystal growth work from 1970s. Many groups working on this hetero-epitaxial seeding have abandoned AlN growth altogether due to lot of persistently encountered problems. In this article, we focus on most of the common problems encountered in this process such as macro- and micro-hole defects, cracks, 3D-nucleation, high dislocation density, and incorporation of unintentional impurity elements due to chemical decomposition of the substrate at very high temperatures. Possible ways to successfully solve some of these issues have been discussed. Other few remaining challenges, namely low-angle grain boundaries and deep UV optical absorption, are also presented in the later part of this work. Particular attention has been devoted in this work on the coloration of the crystals with respect to chemical composition. Wet chemical etching gives etch pit density (EPD) values in the order of 105 cm-2 for yellow-coloured samples, while greenish coloration deteriorates the structural properties with EPD values of at least one order more.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Bernd Wegener ◽  
Maik Behnke ◽  
Stefan Milz ◽  
Volkmar Jansson ◽  
Christian Redlich ◽  
...  

AbstractDespite the high potential of healthy bone to regenerate, the reconstruction of large bone defects remains a challenge. Due to the lack of mechanical stability of existing bone substitutes, recently developed degradable metallic alloys are an interesting alternative providing higher load-bearing capabilities. Degradable iron-based alloys therefore might be an attractive innovation. To test the suitability of a newly-designed iron-based alloy for such applications, an animal experiment was performed. Porous iron-based degradable implants with two different densities and a control group were tested. The implants were positioned in the proximal tibia of Merino sheep. Over a period of 6 and 12 months, blood and histological parameters were monitored for signs of inflammation and degradation. In the histological evaluation of the implants` environment we found degraded alloy particles, but no inflammatory reaction. Iron particles were also found within the popliteal lymph nodes on both sides. The serum blood levels of phosphorus, iron and ferritin in the long term groups were elevated. Other parameters did not show any changes. Iron-based degradable porous bone replacement implants showed a good biocompatibility in this experiment. For a clinical application, however, the rate of degradation would have to be significantly increased. Biocompatibility would then have to be re-evaluated.


2008 ◽  
Vol 130 (9) ◽  
pp. 2869-2876 ◽  
Author(s):  
Suzanne M. Neville ◽  
Gregory J. Halder ◽  
Karena W. Chapman ◽  
Martin B. Duriska ◽  
Peter D. Southon ◽  
...  

Author(s):  
Dong Feng ◽  
Zhaobo Qin ◽  
Quanxing Ren ◽  
Shihao Sun ◽  
Qian Xia ◽  
...  

2011 ◽  
Vol 32 (3) ◽  
pp. 150-228 ◽  
Author(s):  
Lifeng Zhang ◽  
Xuewei Lv ◽  
Alex Tryg Torgerson ◽  
Mujun Long

Sign in / Sign up

Export Citation Format

Share Document