Inductive pressure transducers

1971 ◽  
Vol 14 (1) ◽  
pp. 165-166
Author(s):  
L. V. Novikov ◽  
V. S. Khomenko ◽  
V. V. Ivanov
1974 ◽  
Vol 17 (2) ◽  
pp. 172-173
Author(s):  
B. Ya. Grinshtein ◽  
I. B. Karpovich ◽  
A. P. Kurochkin ◽  
�. L. Noskin

1992 ◽  
Vol 72 (1) ◽  
pp. 302-306 ◽  
Author(s):  
P. H. Saldiva ◽  
W. A. Zin ◽  
R. L. Santos ◽  
D. H. Eidelman ◽  
J. Milic-Emili

In open-chest rats, alveolar pressure was measured with alveolar capsules connected via pliable tubing to inductive pressure transducers. By means of the interrupter technique during constant-flow inflation, it was possible to determine pulmonary static elastance (Est,L) and tissue and airway resistances (Rdiff,L and Rinit,L, respectively). In eight anesthetized paralyzed mechanically ventilated rats, 118 measurements of Rdiff,L and Est,L were performed over a wide range of flows and tidal volumes. There was excellent agreement between the data calculated using transpulmonary pressures and those computed using capsule pressures, the latter being measured at different points of the lung. In another group of rats studied under the same experimental conditions, two capsules were simultaneously placed on different pulmonary lobes. No regional differences in pulmonary mechanics could be detected in either experiment. In addition, alveolar pressure could also be measured accurately by a catheter inserted into lung parenchyma.


1979 ◽  
Vol 101 (4) ◽  
pp. 436-442 ◽  
Author(s):  
R. E. Kirmse

Measurements of velocities and pressure gradients in pulsating turbulent pipe flow are performed by means of a directionally sensitive Laser-Doppler Velocimeter and inductive pressure transducers. The desired accuracy of the instrumentation was confirmed by preliminary tests in turbulent pipe flow without pulsations and in laminar oscillating flow. The temporal and spatial velocity field in the pulsating turbulent pipe flow could be satisfactorily determined for the entire flow field with the exception of the region extremely close to the wall (y < 0.0065, where y expresses the ratio of wall distance to pipe radius). The results are discussed and compared with results of theoretical calculations.


2003 ◽  
Author(s):  
Yuan Mao Huang ◽  
Sheng An Yang

This study introduces an experimental method that can measure air pressures in the vane segments when a sliding-vane rotary compressor performs suction and compression phases in stable or unstable rotational speeds. When the air pressures of these two phases can be measured, the intake effect of the compressor’s inlet and the seal effect of the vane segments can be evaluated, respectively. Because a frequency converter provides unstable rotational speeds when it controls rotational speeds of a motor with a compressor, an encoder mounted on the output shaft of the motor was applied to record the angular location of the compressor rotor. Two strain gauge type pressure transducers were inserted into the cover plate of the compressor to measure air pressures in the vane segments. Comparing the signals of the encoder with pressure transducers, the air pressures in completions of suction and compression phases could be determined in stable or unstable rotational speeds. The air pressures when the compressor performed suction and compression phases were 99.5 kPa and 153 kPa, respectively, in 1400 rpm. The air pressure when the compressor performed suction phase decreased with the rotational speed faster than 800 rpm. The size or shape of the inlet port of the compressor should be enlarged or modified to provide the suction air pressure without dropping too much. The designed air pressure when the compressor performed compression phase was 244 kPa in 140 rpm, the manufacture precision of the compressor should be increased to decrease leakage.


1991 ◽  
Vol 261 (2) ◽  
pp. G263-G268 ◽  
Author(s):  
M. D. Crowell ◽  
G. Bassotti ◽  
L. J. Cheskin ◽  
M. M. Schuster ◽  
W. E. Whitehead

This study monitored high-amplitude propagated contractions (HAPCs) in ambulating subjects over a 24-h period using a new ambulatory recording system. Twelve healthy volunteers aged 34 +/- 5.96 yr participated. Approximately 12 h after a Colyte bowel prep, a small catheter (OD less than 3 mm), containing three solid-state pressure transducers spaced 5 cm apart, was positioned by flexible sigmoidoscope at 40-50 cm from the anal verge. A battery-operated data recorder sampled the pressure at each port at 1 Hz and stored the values on all ports if any port exceeded 75 mmHg. At the conclusion of the 24-h period, an X-ray was taken to confirm the location of the catheter. Fifty-four percent of all HAPCs preceded a bowel movement by less than or equal to 1 h. Forty-nine percent of all HAPCs occurred within 1 h after a high-fat meal, and 33% occurred within 1 h of morning awakening. Reverse propagated waves, not previously described in the colon, were observed in three individuals. Spontaneous high-amplitude caudally propagated contractions occur 6.9 +/- 1.5 times/24 h in the sigmoid colon in ambulating asymptomatic individuals and are temporally related to defecation and meals. Peristaltic activity is decreased during sleep. This recording technique was reliable and well tolerated in all participants.


Energies ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 2099
Author(s):  
Jian Gao ◽  
Anren Yao ◽  
Yeyi Zhang ◽  
Guofan Qu ◽  
Chunde Yao ◽  
...  

The super-knock poses new challenges for further increasing the power density of spark ignition (SI) engines. The critical factors and mechanism connecting regarding the occurrence of super-knock are still unclear. Misfire is a common phenomenon in SI engines that the mixture in cylinder is not ignited normally, which is often caused by spark plug failure. However, the effect of misfire on engine combustion has not been paid enough attention to, particularly regarding connection to super-knock. The paper presents the results of experimental investigation into the relationship between super-knock and misfires at low speed and full load conditions. In this work, a boosted gasoline direct injection (GDI) engine with an exhaust manifold integrated in the cylinder head was employed. Four piezoelectric pressure transducers were used to acquire the data of a pressure trace in cylinder. The spark plugs of four cylinders were controlled manually, of which the ignition system could be cut off as demanded. In particular, a piezoelectric pressure transducer was installed at the exhaust pipe before the turbocharger to capture the pressure traces in the exhaust pipe. The results illustrated that misfires in one cylinder would cause super-knock in the other cylinders as well as the cylinder of itself. After one cylinder misfired, the unburned mixture would burn in the exhaust pipe to produce oscillating waves. The abnormal pressure fluctuation in the exhaust pipe was strongly correlated with the occurrence of super-knock. The sharper the pressure fluctuation, the greater the intensity of knock in the power cylinder. The cylinder whose exhaust valve overlapped with the exhaust valve of the misfired cylinder was prone to super-knock.


1978 ◽  
Vol 100 (1) ◽  
pp. 111-120 ◽  
Author(s):  
F. O. Carta ◽  
A. O. St. Hilaire

Tests were performed on a linear cascade of airfoils oscillating in pitch about their midchords at frequencies up to 17 cps, at free-stream velocities up to 200 ft/s, and at interblade phase angles of 0 deg and 45 deg, under conditions of high aerodynamic loading. The measured data included unsteady time histories from chordwise pressure transducers and from chordwise hot films. Unsteady normal force coefficient, moment coefficient, and aerodynamic work per cycle of oscillation were obtained from integrals of the pressure data, and indications of the nature and extent of the separation phenomenon were obtained from an analysis of the hot-film response data. The most significant finding of this investigation is that a change in interblade phase angle from 0 deg to 45 deg radically alters the character of the unsteady blade loading (which governs its motion in a free system) from stable to unstable. Furthermore, the stability or instability is governed primarily by the phase angle of the pressure distribution (relative to the blade motion) over the forward 10–15 percent of the blade chord. Reduced frequency and mean incidence angle changes were found to have a relatively minor effect on stability for the range of parameters tested.


Sign in / Sign up

Export Citation Format

Share Document