Complete determination of direct reaction amplitude in fluctuation experiment with polarized beam

1985 ◽  
Vol 320 (4) ◽  
pp. 621-624
Author(s):  
S. Yu. Kun
1991 ◽  
Vol 24 (6) ◽  
pp. 982-986 ◽  
Author(s):  
T. Ishikawa ◽  
K. Hirano ◽  
S. Kikuta

A new method for complete determination of polarization state in the hard X-ray region is described. The system consists of a perfect-crystal phase retarder and a linear polarization analyzer. This method gives not only the amplitude ratio of mutually perpendicular electric vector components and the phase shift between them but also the proportion of unpolarized radiation.


2014 ◽  
Vol 68 (11) ◽  
Author(s):  
Pavel Mikuška ◽  
Lukáš Bružeňák ◽  
Zbyněk Večeřa

AbstractA method for the rapid and sensitive determination of peroxyacetyl nitrate (PAN) in air based on a chemiluminescence reaction with an alkaline solution of luminol in the chemiluminescence aerosol detector is described. The PAN is chromatographically separated from nitrogen dioxide and ozone in a packed column filled with 5 % OV-1 on Chromosorb 30/60 and the eluted PAN is detected via the direct reaction with the luminol solution consisting of 0.002 mol L−1 luminol, 1 vol. % Brij-35 and 0.1 mol L−1 KOH. The limit of detection is 14.9 ng m−3 (3 ppt) of PAN. Alternatively, the PAN after separation is thermally converted to NO2 which is detected by the chemiluminescence reaction with a solution consisting of 0.002 mol L−1 luminol, 0.5 mol L−1 KOH, 0.2 mol L−1 Na2SO3, 0.1 mol L−1 KI, 0.05 mol L−1 EDTA and 0.5 vol. % triton X-100. The alternative approach affords the simultaneous determination of PAN and NO2. The limit of detection is 50 ppt of PAN and 50 ppt of NO2. The time resolution is 3 min. The method was applied to the measurement of ambient peroxyacetyl nitrate in air.


2021 ◽  
Vol 81 (8) ◽  
Author(s):  
Claudio Corianò ◽  
Matteo Maria Maglio ◽  
Dimosthenis Theofilopoulos

AbstractWe elaborate on the structure of the conformal anomaly effective action up to 4-th order, in an expansion in the gravitational fluctuations (h) of the background metric, in the flat spacetime limit. For this purpose we discuss the renormalization of 4-point functions containing insertions of stress-energy tensors (4T), in conformal field theories in four spacetime dimensions with the goal of identifying the structure of the anomaly action. We focus on a separation of the correlator into its transverse/traceless and longitudinal components, applied to the trace and conservation Ward identities (WI) in momentum space. These are sufficient to identify, from their hierarchical structure, the anomaly contribution, without the need to proceed with a complete determination of all of its independent form factors. Renormalization induces sequential bilinear graviton-scalar mixings on single, double and multiple trace terms, corresponding to $$R\square ^{-1}$$ R □ - 1 interactions of the scalar curvature, with intermediate virtual massless exchanges. These dilaton-like terms couple to the conformal anomaly, as for the chiral anomalous WIs. We show that at 4T level a new traceless component appears after renormalization. We comment on future extensions of this result to more general backgrounds, with possible applications to non local cosmologies.


2012 ◽  
Vol 58 (1) ◽  
pp. 88-94
Author(s):  
K. Li ◽  
L.Z. Nu ◽  
K.L. Khe ◽  
K.H. Song

A sensitive chemiluminescence method, based on the enhancive effect of phenobarbital on the chemiluminescence reaction between luminol and dissolved oxygen in a flow injection system, was proposed for the determination of phenobarbital. The chemiluminescence intensity responded to the concentration of phenobarbital linearly ranging from 0.05 to 10 ng⋅ml-1 with the detection limit of 0.02 ng⋅ml-1 (3σ). At a flow rate of 2.0 ml⋅min-1, a complete determination of phenobarbital, including sampling and washing, could be accomplished in 0.5 min, offering the sampling efficiency of 120 h-1 accordingly. The method was applied successfully in an assay of PB for pharmaceutical preparations, human urine and serum without any pretreatment with recovery from 95.7 to 106.7% and RSDs of less than 3.0%.


1968 ◽  
Vol 8 (3) ◽  
pp. 115-121 ◽  
Author(s):  
P. Bohler ◽  
W. Schumann

Sign in / Sign up

Export Citation Format

Share Document