scholarly journals Lung ultrasound findings in pediatric patients with COVID-19

Author(s):  
Carmina Guitart ◽  
◽  
Ricardo Suárez ◽  
Mònica Girona ◽  
Sara Bobillo-Perez ◽  
...  
2015 ◽  
Vol 21 ◽  
pp. 200
Author(s):  
Adriana Herrera ◽  
Claudia Zapata ◽  
Parul Jayakar ◽  
Aparna Rajadhyaksha ◽  
Ricardo Restrepo ◽  
...  

Author(s):  
Yale Tung Chen ◽  
Milagros Martí de Gracia ◽  
Maria Luz Parra Gordo ◽  
Silvia Ossaba Velez ◽  
Sergio Agudo-Fernández

2020 ◽  
Vol 8 (1) ◽  
pp. 50-50
Author(s):  
Seyed Hossein Ojaghi Haghighi ◽  
Neda Hamed ◽  
Shiva Ebrahimi ◽  
Jafar Ghobadi ◽  
Hoorolnesa Ameli

Introduction: Congestive heart failure is heart muscle failure that causes pulmonary congestion and eventually pulmonary edema, which despite recent medical advances, is still a progressive syndrome with high mortality, the prevalence of which has increased in recent decades. Therefore, in this study we compared lung ultrasound findings in acute heart failure patients with the BNP. Methods: This study was performed in the emergency room of Imam Reza hospital in Tabriz. For patients entering the emergency room after taking a history, both standard gold (BNP) tests and beside ultrasound of the lung were performed. Ultrasound was performed at the same time as obtaining blood sample to ensure that the ultrasound specialist did not know the result of diagnosis. During the ultrasound, if there were multiple B-Lines that were at least 3 mm apart, patient was diagnosed with pulmonary edema due to heart failure. Results: Number of participants in this study was 108 people, 54.6% of whom were men and the rest were women. The correlation coefficient between width and number of kerley lines was 0.79, between NT-pro BNP and width of kerley lines was 0.65 and between NT-pro BNP and number of kerley lines was 0.77, which indicates a significant positive correlation (P value <0.001). Conclusion: The results of present study showed that in patients with acute heart failure, the number and width of kerley lines in pulmonary ultrasound evaluation increase rapidly. There is also a high correlation between number and length of kerley lines with NT-pro BNP serum values.


2021 ◽  
Vol 26 (Supplement_1) ◽  
pp. e65-e66
Author(s):  
Noah Marzook ◽  
Alexander Dubrovsky

Abstract Primary Subject area Emergency Medicine - Paediatric Background Unlike the lung ultrasound (LU) findings of pneumonia, bronchiolitis, pleural effusions and pneumothorax, which have all been well described, the sonographic pattern of asthma remains unclear. Previous pediatric studies have shown that pediatric patients with acute asthma exacerbations had positive LU findings. It is also unclear whether these findings were the result of acute infections associated with the exacerbation or if the findings would be present at baseline, outside an exacerbation in an asthmatic patient. Objectives The primary objective of this study is to characterize lung ultrasound (LU) findings in stable asthma pediatric patients presenting in a tertiary care asthma or respiratory clinic. Design/Methods Eligible patients &gt;6 years of age, underwent a LU by the study sonographer between December 19, 2017 to June 25, 2019, during their regular follow up visit at the pulmonology clinic or scheduled pulmonary function test. Patients were defined as asthmatic if they had a positive methacholine challenge test (MCT) or spirometry at the day of the visit or in the past. Patients were excluded if they had an upper respiratory tract infection in the past 4 weeks, or had any other known pulmonary diseases. Baseline demographic and asthma severity (ISAAC score, ACQ-7) questionnaires were filled out by the patients, following which they underwent a LU by a novice sonographer using a 6-zone protocol. A blinded expert sonographer interpreted the images offline. A positive LU was defined as presence of more than 3 B-lines, consolidation (&lt;1cm or &gt;1cm), absent lung slide, and/or presence of pleural fluid. Results Fifty-two patients were enrolled in the study and 19.2% (CI 8.31-30.15) of the asthma patients had positive LU findings. The positive LU findings were diverse including B-lines (80%), small consolidation (80%), pleural line anomalies (10%). Positive LU findings were not correlated to any demographic value. Conclusion In our study, 19.2% of asthma patients at baseline have a positive LU. Lung consolidations larger than 1 cm were rarely seen. There were no significant differences between demographic data in asthmatic patients with positive compared to those with negative LUS. This positive LU scan rate is in keeping with a prior study on LU in pediatrics.


2018 ◽  
Vol 6 (1) ◽  
pp. 202-207 ◽  
Author(s):  
Elke Platz ◽  
Allison Merz ◽  
Montane Silverman ◽  
Eldrin Lewis ◽  
John D. Groarke ◽  
...  

2020 ◽  
Author(s):  
Letizia Consoli ◽  
Vittorio Bendotti ◽  
Sara Cicchinelli ◽  
Federico Gaioni ◽  
Paola Prandolini ◽  
...  

Abstract In December 2019, a novel coronavirus (SARS-Cov-2) was first reported in Wuhan, China, and rapidly spread around the world, leading to an international emerging public health emergency. As reported from Chinese experiences, approximately 20% of patients had a severe course, requiring intensive care, with an overall case fatality rate of 2.3%. In diagnosis, chest computed tomography most commonly showed ground-glass opacity with or without consolidative patterns.Herein we report a case of a patient affected by COVID-19 pneumonia referred in the emergency department of our institution on 4 April 2020 with peculiar lung ultrasound findings.


Author(s):  
Mustafa J. Musa ◽  
Mohamed Yousef ◽  
Mohammed Adam ◽  
Awadalla Wagealla ◽  
Lubna Boshara ◽  
...  

: Lung ultrasound [LUS] has evolved considerably over the last years. The aim of the current review is to conduct a systematic review reported from a number of studies to show the usefulness of [LUS] and point of care ultrasound for diagnosing COVID-19. A systematic search of electronic data was conducted including the national library of medicine, and the national institute of medicine, PubMed Central [PMC] to identify the articles depended on [LUS] to monitor COVID-19. This review highlights the ultrasound findings reported in articles before the pandemic [11], clinical articles before COVID-19 [14], review studies during the pandemic [27], clinical cases during the pandemic [5] and other varying aims articles. The reviewed studies revealed that ultrasound findings can be used to help in the detection and staging of the disease. The common patterns observed included irregular and thickened A-lines, multiple B-lines ranging from focal to diffuse interstitial consolidation, and pleural effusion. Sub-plural consolidation is found to be associated with the progression of the disease and its complications. Pneumothorax was not recorded for COVID-19 patients. Further improvement in the diagnostic performance of [LUS] for COVID-19 patients can be achieved by using elastography, contrast-enhanced ultrasound, and power Doppler imaging.


2021 ◽  
pp. respcare.09108
Author(s):  
Caroline Espersen ◽  
Elke Platz ◽  
Kristoffer Grundtvig Skaarup ◽  
Mats Christian Højbjerg Lassen ◽  
Jannie Nørgaard Lind ◽  
...  

2020 ◽  
Vol 8 ◽  
pp. 2050313X2095891
Author(s):  
Debo Yun ◽  
Yan Cui ◽  
Yuan Geng ◽  
Yujiao Yang

Knowledge of lung ultrasound characteristics of coronavirus disease 2019 pneumonia might be useful for early diagnosis and clinical monitoring of patients, and lung ultrasound can help to control the spread of infection in healthcare settings. In this case report, a 36-year-old man with severe acute respiratory syndrome coronavirus 2 infection was diagnosed by reverse transcription-polymerase chain reaction testing of a nasopharyngeal swab. The lung ultrasound findings for this patient were the interstitial-alveolar damage showing bilateral, diffuse pleural line abnormalities, subpleural consolidations, white lung areas and thick, irregular vertical artifacts. When the patient recovered from the severe acute respiratory syndrome coronavirus 2 infection, lung ultrasound images showed a normal pleural line with A-lines regularly reverberating. Performing lung ultrasound at the bedside minimizes the need to move the patient, thus reducing the risk of spreading infection among healthcare staff. Lung ultrasound is useful for early diagnosis and evaluation of the severity of coronavirus disease 2019 pneumonia and for monitoring its progress over the course of the disease.


2020 ◽  
Vol 7 ◽  
Author(s):  
Davide Pata ◽  
Piero Valentini ◽  
Cristina De Rose ◽  
Rita De Santis ◽  
Rosa Morello ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document