scholarly journals Numerical Study of Atrial Fibrillation Effects on Flow Distribution in Aortic Circulation

2020 ◽  
Vol 48 (4) ◽  
pp. 1291-1308 ◽  
Author(s):  
Amin Deyranlou ◽  
Josephine H. Naish ◽  
Christopher A. Miller ◽  
Alistair Revell ◽  
Amir Keshmiri
Author(s):  
Amin Deyranlou ◽  
Christopher A. Miller ◽  
Alistair Revell ◽  
Amir Keshmiri

AbstractAtrial fibrillation (AF) can alter intra-cardiac flow and cardiac output that subsequently affects aortic flow circulation. These changes may become more significant where they occur concomitantly with ageing. Aortic ageing is accompanied with morphological changes such as dilation, lengthening, and arch unfolding. While the recognition of AF mechanism has been the subject of numerous studies, less focus has been devoted to the aortic circulation during the AF and there is a lack of such investigation at different ages. The current work aims to address the present gap. First, we analyse aortic flow distribution in three configurations, which attribute to young, middle and old people, using geometries constructed via clinical data. We then introduce two transient inlet flow conditions representative of key AF-associated defects. Results demonstrate that both AF and ageing negatively affect flow circulation. The main consequence of concomitant occurrence is enhancement of endothelial cell activation potential (ECAP) throughout the vascular domain, mainly at aortic arch and descending thoracic aorta, which is consistent with some clinical observations. The outcome of the current study suggests that AF exacerbates the vascular defects occurred due to the ageing, which increases the possibility of cardiovascular diseases per se.


Author(s):  
Miad Yazdani ◽  
Jamal Seyed-Yagoobi

The control of fluid flow distribution in micro-scale tubes is numerically investigated. The flow distribution control is achieved via electric conduction mechanism. In electrohydrodynamic (EHD) conduction pumping, when an electric field is applied to a fluid, dissociation and recombination of electrolytic species produces heterocharge layers in the vicinity of electrodes. Attraction between electrodes and heterocharge layers induces a fluid motion and a net flow is generated if the electrodes are asymmetric. The numerical domain comprises a 2-D manifold attached to two bifurcated tubes with one of the tubes equipped with a bank of uniquely designed EHD-conduction electrodes. In the absence of electric field, the total flow supplied at the manifold’s inlet is equally distributed among the tubes. The EHD-conduction, however, operates as a mechanism to manipulate the flow distribution to allow the flow through one branch surpasses the counterpart of the other branch. Its performance is evaluated under various operating conditions.


2018 ◽  
Vol 140 (5) ◽  
Author(s):  
Binaya Baidar ◽  
Jonathan Nicolle ◽  
Chirag Trivedi ◽  
Michel J. Cervantes

The Winter-Kennedy (WK) method is commonly used in relative discharge measurement and to quantify efficiency step-up in hydropower refurbishment projects. The method utilizes the differential pressure between two taps located at a radial section of a spiral case, which is related to the discharge with the help of a coefficient and an exponent. Nearly a century old and widely used, the method has shown some discrepancies when the same coefficient is used after a plant upgrade. The reasons are often attributed to local flow changes. To study the change in flow behavior and its impact on the coefficient, a numerical model of a semi-spiral case (SC) has been developed and the numerical results are compared with experimental results. The simulations of the SC have been performed with different inlet boundary conditions. Comparison between an analytical formulation with the computational fluid dynamics (CFD) results shows that the flow inside an SC is highly three-dimensional (3D). The magnitude of the secondary flow is a function of the inlet boundary conditions. The secondary flow affects the vortex flow distribution and hence the coefficients. For the SC considered in this study, the most stable WK configurations are located toward the bottom from θ=30deg to 45deg after the curve of the SC begins, and on the top between two stay vanes.


Author(s):  
Thomas D. Foust ◽  
Kurt D. Hamman ◽  
Brent A. Detering

The performance and capacity of Kraft recovery boilers is sensitive to black liquor velocity, droplet size and flow distribution in the furnace. Studies have shown that controlling droplet size and flow distribution improves boiler efficiency while allowing increased flight drying and devolatilization, and decreased carryover. The purpose of this study is to develop a robust two-phase numerical model to predict black liquor splashplate nozzle spray characteristics. A three-dimensional time dependent numerical study of black liquor sheet formation and sheet breakup is described. The volume of fluid (VOF) model is used to simulate flow through the splashplate nozzle up to initial sheet breakup and droplet formation. The VOF model solves the conservation equations of volume fraction and momentum utilizing the finite volume technique. Black liquor velocity, droplet size and flow distribution over a range of operating parameters are simulated using scaled physical models of splashplate nozzles. The VOF model is compared to results from a flow visualization experiment and experimental data found in the literature. The details of the simulation and experimental results are presented.


Author(s):  
Manoj Siva ◽  
Arvind Pattamatta ◽  
Sarit Kumar Das

A common assumption in basic heat exchanger design theory is that fluid is distributed uniformly at the inlet of the exchanger on each fluid side and throughout the core. However in reality, uniform flow distribution is never achieved in a heat exchanger and is referred to as flow maldistribution. Flow maldistribution is generally well understood for the macrochannel system. But it is still unclear whether the assumptions underlying the flow distribution in conventional macrochannel heat exchangers hold good for microchannel system. In this regard, extensive numerical simulations are carried out in a ‘U’ type parallel micro-channel system in order to study flow and heat transfer maldistribution and validated with in-house experimental data. A detailed parametric analysis is carried out to characterize flow maldistribution in a microchannel system and to study the effect of geometrical factors such as number of channels, n, Area of cross section of the channel Ac, manifold cross section area Ap, and flow parameter such as Reynolds number, Re, on the pressure and temperature distribution. In order to minimize the variation in pressure and to reduce temperature hot spots in the microchannel, a Response surface based surrogate approximation (RSA) and a gradient based search algorithm are used to arrive at the best configuration of microchannel cooling system. A three level factorial design involving three parameters namely Ac/Ap, Re, n are considered. The results from the optimization indicate that the case of n = 5, Ac/Ap = 0.12, and Re = 100 is the best possible configuration to alleviate flow maldistribution and hotspot formation in microchannel cooling system.


Author(s):  
Selvan Bellan ◽  
Cristina Cerpa Saurez ◽  
Jose Gonzalez-Aguilar ◽  
Manuel Romero

A lab-scale solar thermochemical reactor is designed and fabricated to study the thermal reduction of non-volatile metal oxides, which operates simultaneously as solar collector and as chemical reactor. The main purpose of this reactor is to achieve the first step in two-step thermochemical cycles. The chemical conversion rate strongly depends on the temperature and fluid flow distribution around the reactant, which are determined by the reactor geometry. The optimal design depends on the constraints of the problem and on the operating parameters. Hence, the objective of this investigation is to analyze the heat and mass transfer in the vertically-oriented chemical reactor by a CFD model and to optimize the reactor design. The developed numerical model is validated by comparing the simulation results with reported model. The influence of different technical and operating parameters on the temperature distribution and the fluid flow of the reactor are studied.


Author(s):  
V. Manoj Siva ◽  
Arvind Pattamatta ◽  
Sarit Kumar Das

A common assumption in basic heat exchanger design theory is that fluid is distributed uniformly at the inlet of the exchanger on each fluid side and throughout the core. However, in reality, uniform flow distribution is never achieved in a heat exchanger and is referred to as flow maldistribution. Flow maldistribution is generally well understood for the macrochannel system. But it is still unclear whether the assumptions underlying the flow distribution in conventional macrochannel heat exchangers hold good for microchannel system. In this regard, extensive numerical simulations are carried out in a “U” type parallel microchannel system in order to study flow and heat transfer maldistribution and validated with in-house experimental data. A detailed parametric analysis is carried out to characterize flow maldistribution in a microchannel system and to study the effect of geometrical factors such as number of channels, n, Area of cross section of the channel Ac, manifold cross section area Ap, and flow parameter such as Reynolds number, Re, on the pressure and temperature distribution. In order to minimize the variation in pressure and to reduce temperature hot spots in the microchannel, a response surface based surrogate approximation and a gradient based search algorithm are used to arrive at the best configuration of microchannel cooling system. A three level factorial design involving three parameters namely Ac/Ap, Re, n are considered. The results from the optimization indicate that the case of n = 7, Ac/Ap = 0.69, and Re = 100 is the best possible configuration to alleviate flow maldistribution and hotspot formation in microchannel cooling system.


2011 ◽  
Vol 110-116 ◽  
pp. 2529-2536 ◽  
Author(s):  
Nityanand Pawar ◽  
R.S. Maurya

The performance of a plate heat exchanger (PHE) is severely influenced by non-uniform distribution of flow among its channels. Not only the PHEs, but many other process equipment needs uniform flow distribution for their optimum performance. Flow maldistribution (non-uniform distribution) is a common design problem which always puzzles process equipment designers. Being important design parameters, it has been investigated by several researchers and case based solution has been proposed and documented. Present numerical work is intended to target this aspect of the problem of PHEs but starts with a general investigation with simple multichannel geometry. The numerical setup consists of two headers having multiple channels for U-and Z-turn flow configuration under multichannel geometry and a simplified PHE for plate heat exchanger simulation. The problem has been investigated from hydrodynamic and thermodynamic view point. For hydrodynamic study, flow has been varied for Reynolds number 120 to 17600. It has been found that channel flow goes on reducing along downstream side. In thermal study the effect of wall temperature on air flow mal distribution has been investigated. Numerical results have been validated with the experimental results. Investigation reveals new features of flow mal-distribution which is helpful in better understanding of associated mal-distribution physics.


2017 ◽  
Vol 79 (7-3) ◽  
Author(s):  
Amirah M. Sahar ◽  
A. I. M. Shaiful

Parallel microchannels have been widely used in cooling of compact electronic equipment due to large contact area with liquid and availability of large mass of fluid to carry away heat. However, understanding of flow distribution for microchannel parallel system is still unclear and there still lack of studies give a clear pictures to understand the complex flow features which cause the flow maldistribution. Generally, the geometrical structure of the manifold and micro channels play an important role in flow distribution between micro channels, which might affects the heat and mass transfer efficiency, even the performance of micro exchangers. A practical design of exchanger basically involves the selection of an optimized solution, keeping an optimal balance between gain in heat transfer and pressure drop penalty. A parallel microchannels configurations consisting inlet and outlet rectangular manifold were simulated to study flow distribution among the channels were investigated numerically by using Ansys Fluent 14.5. The numerical results was validated using existing experimental data and showed a similar trend with values 1% higher than experimental data. The influence of inlet/outlet manifold area and inlet/outlet arrangement on flow distribution in channels were carried out in this study. Based on the predicted flow non-uniformity value, 𝜙, Z- type flow arrangement exhibits higher value of 𝜙, which is 8%, followed by U-type, 2.6% and the I-type, 2.49%. Thus, a better uniformity of velocity and temperature distributions can be achieved in I-shape flow arrangement. The behavior of the flow distributions inside channels is due to the vortices that occurred at manifold. Besides comparing the pressure drop for case 1(D1) and case 2(D2), it is worth to mention that, as the area of inlet and outlet manifold decrease by 50%, the pressure drop is increasing about 5%. However, the inlet/outlet area of manifold on velocity and fluid temperature distributions was insignificant.


Sign in / Sign up

Export Citation Format

Share Document