The New LMK Primary Standard for Dew-Point Sensor Calibration: Evaluation of the High-Range Saturator Efficiency

2008 ◽  
Vol 29 (5) ◽  
pp. 1652-1659 ◽  
Author(s):  
Domen Hudoklin ◽  
Janko Drnovšek
Author(s):  
Doaa Mohamed Abd El-Gelil ◽  
Mohamed Gamal Ahmed

Extension of dew-point temperature scale has been performed using a two-temperature (2-T), constant pressure humidity generator that is developed for the first time by the National Institute of Standard (NIS) in order to extend the calibration capabilities to the high dew-point temperature range at NIS. It relies on the saturation of a stream of gas flowing over a water surface maintained at constant, well-known, temperature. In this paper, primary realization of dew-point temperature scale in a dew-point temperature range up to +50 °C was performed to extend calibration capabilities and to improve the uncertainties of the dew-point temperature scale realization. Several experiments were carried out in order to characterize the generator. Characterization comprises studies of the saturator efficiency, temperature stability and a comparison with a calibrated chilled-mirror hygrometer. The results of the efficiency tests showed good performance of the generator. For uncertainty of measurements, a thorough analysis was also described representing estimations of contributions for all the sources that possibly affect measurements.


Sensors ◽  
2020 ◽  
Vol 20 (3) ◽  
pp. 584
Author(s):  
Han Haitjema

Displacement measuring sensors play an essential role in all aspects of dimensional metrology. They can be used for direct displacement measurements but more often they are part of a measurement system, such as an atomic force microscope, roughness tester or a coordinate measuring machine (CMM). In order to achieve traceable measurements that can be related to the meter, these sensors must be calibrated against a reference standard that is more noise- and error-free than the sensor under test. A description of the various methods to achieve the ultimate traceability, repeatability and accuracy of such a calibration system is the main part of this paper. Various interferometric methods will be reviewed including several methods that use directly a primary standard as a reference: either an iodine-stabilized laser or a frequency comb. It is shown that various methods exist to quantify or mitigate the periodic errors that are inherent to interferometric methods. Also it is shown that knowledge of this periodicity may lead to a separation of periodic and non-periodic non-linearity errors of both the calibration instrument as the sensor under test. This review is limited to small-range sensors, typically with a range <100 μm. It is concluded that today’s technology enables sound and traceable sensor calibration up to the sub-nano and even picometer level of uncertainties


1968 ◽  
Vol 19 (03/04) ◽  
pp. 423-429 ◽  
Author(s):  
G. M Thelin ◽  

SummaryA stable, lyophilized AHF reference plasma has been prepared from pooled plasma from at least 50 normal healthy donors and standardized against a primary standard of fresh plasma from 20 healthy male donors aged 20 to 40. Average AHF potency of a typical lot is 98.8%, and moisture content is less than 0.5%. Under storage at -25° C, this AHF reference plasma is stable for at least 18 months. It has been used in several major coagulation laboratories, and has given consistently satisfactory and reproducible results in AHF assays.


2020 ◽  
pp. 8-12
Author(s):  
Alexandr V. Oborin ◽  
Anna Y. Villevalde ◽  
Sergey G. Trofimchuk

The results of development of the national primary standard of air kerma, air kerma rate, exposure, exposure rate and energy flux for X-rays and gamma radiation GET 8-2011 in 2019 are presented according to the recommendations of the ICRU Report No. 90 “Key Data for Ionizing-Radiation Dosimetry: Measurement Standards and Applications”. The following changes are made to the equations for the units determination with the standard: in the field of X-rays, new correction coefficients of the free-air ionization chambers are introduced and the relative standard uncertainty of the average energy to create an ion pair in air is changed; in the field of gamma radiation, the product of the average energy to create an ion pair in air and the electron stopping-power graphite to air ratio for the cavity ionization chambers is changed. More accurate values of the units reproduced by GET 8-2019 are obtained and new metrological characteristics of the standard are stated.


2020 ◽  
pp. 6-10
Author(s):  
A.E. Aslanyan ◽  
E.G. Aslanyan ◽  
S.M. Gavrilkin ◽  
A.S. Doynikov ◽  
A.N. Shchipunov

The article presents the results of studies to improve the National primary standard machine for hardness of metals on the shore D scale GET 161-2001, which were performed in FSUE “VNIIFTRI” from 2016 to 2018 in accordance with the technical task of Rosstandart.The improvement was carried out in order to ensure the uniformity of hardness measurements on the Leeb scales. The created new parts of the primary standard machine, which are settings for reproducing hardness numbers on the Leeb scales, are considered. Metrological characteristics of the upgraded and adopted National primary standard machine (GET 161-2019) were investigated, the budget of measurement uncertainty was calculated for reproducing hardness numbers on the Leeb scales.


2020 ◽  
pp. 3-7
Author(s):  
Vladlen Ya. Shifrin ◽  
Denis I. Belyakov ◽  
Alexander E. Shilov ◽  
Denis D. Kosenko

The results of works aimed at increasing the level of uniformity of measurements of the magnetic induction of a constant field – the basic value in the field of magnetic measurements. A set of equipment for reproducing a unit of magnetic induction of a constant field in the range of 1–25 mT was created and described. The inclusion of this complex in the State primary standard of units of magnetic induction, magnetic flux, magnetic moment and magnetic induction gradient GET 12-2011 will ensure the reproduction and direct transmission of the unit of permanent magnetic induction in the ranges of not only weak (10–3–1 mT), but medium (1–25 mT) and strong (0.025–1 T) magnetic fields. A quantum cesium magnetometer based on the resolved structure of cesium atoms was created to transmit the unit of magnetic induction to the region of medium fields. The procedure for calculating the frequency conversion coefficients to magnetic induction of the created quantum cesium magnetometer is described. The uncertainty budget for reproducing a unit of magnetic induction of a constant field using the created complex is estimated.


2020 ◽  
pp. 59-63
Author(s):  
A.S. Bondarenko ◽  
A.S. Borovkov ◽  
I.M. Malay ◽  
V.A. Semyonov

The analysis of the current state of the reflection coefficient measurements in waveguides at millimeter waves is carried out. An approach for solving the problem of reproducing the reflection coefficient measurement scale is proposed. Mathematical equations, which are the basis of the reflection coefficient measurement equation are obtained. The method of determining the metrological performance of reflection coefficient unit’s reference standards is developed. The results of electrodynamic modeling and analytical calculations by the developed method are compared. It is shown that this method can be used for reproducing the reflection coefficient unit in the development of the State primary standard.