Lipolytic Effect of Staphylococcus warneri for Obtaining High-Quality Fishmeal from Fish Waste Fermentation

Author(s):  
Quintero P. Natalia ◽  
Ramírez T. Cristina ◽  
Bolivar E. Germán
RSC Advances ◽  
2014 ◽  
Vol 4 (59) ◽  
pp. 31462-31468 ◽  
Author(s):  
Devarapaga Madhu ◽  
Bhaskar Singh ◽  
Yogesh C. Sharma

A low cost raw material obtained from the discarded parts of fish (Cirrhinus mrigala, Cirrhinus cirrhosa, Cirrhinus reba) was utilized as feedstock oil and catalyst for the synthesis of biodiesel.


1973 ◽  
Vol 30 (11) ◽  
pp. 1745-1747 ◽  
Author(s):  
Y. Onoue ◽  
V. M. Riddle

A high quality proteinaceous product is recoverable in 35% yield from fish waste by a process of peptic hydrolysis followed by a pepsin-catalyzed recombination of soluble peptides to form plastein. Hydrolysis is at pH 2.0 and 37 C for 6 hr. Soluble peptides are then separated from insoluble residue, adjusted to pH 4.5, concentrated at 45 C to 30% protein solids, and incubated for 24 hr at 37 C with additional pepsin. The insoluble plastein formed during incubation is filtered, washed, and dried. In a pilot experiment with fillet waste from Petrale sole (Eopsetta jordani), the yield was 35% of total original protein. Proximate composition of the product was: protein, 96.1%; moisture, 2.9%; ash, 0.5%; and lipid, 0.0%. The plastein contained a higher proportion of essential amino acids than did a hydrolysate of the whole waste, all except tryptophan exceeding FAO reference standards.


Molecules ◽  
2019 ◽  
Vol 24 (12) ◽  
pp. 2234 ◽  
Author(s):  
Chi-Hao Wang ◽  
Chien Thang Doan ◽  
Van Bon Nguyen ◽  
Anh Dzung Nguyen ◽  
San-Lang Wang

Seafood such as fish, shellfish, and squid are a unique source of nutrients. However, many marine processing byproducts, such as viscera, shells, heads, and bones, are discarded, even though they are rich sources of structurally diverse bioactive nitrogenous components. Based on emerging evidence of their potential health benefits, these components show significant promise as functional food ingredients. Fish waste components contain significant levels of high-quality protein, which represents a source for biofunctional peptide mining. The chitin contained in shrimp shells, crab shells, and squid pens may also be of value. The components produced by bioconversion are reported to have antioxidative, antimicrobial, anticancer, antihypertensive, antidiabetic, and anticoagulant activities. This review provides an overview of the extraordinary potential of processing fish and chitin-containing seafood byproducts via chemical procedures, enzymatic and fermentation technologies, and chemical modifications, as well as their applications.


1966 ◽  
Vol 24 ◽  
pp. 51-52
Author(s):  
E. K. Kharadze ◽  
R. A. Bartaya

The unique 70-cm meniscus-type telescope of the Abastumani Astrophysical Observatory supplied with two objective prisms and the seeing conditions characteristic at Mount Kanobili (Abastumani) permit us to obtain stellar spectra of a high quality. No additional design to improve the “climate” immediately around the telescope itself is being applied. The dispersions and photographic magnitude limits are 160 and 660Å/mm, and 12–13, respectively. The short-wave end of spectra reaches 3500–3400Å.


Author(s):  
R. L. Lyles ◽  
S. J. Rothman ◽  
W. Jäger

Standard techniques of electropolishing silver and silver alloys for electron microscopy in most instances have relied on various CN recipes. These methods have been characteristically unsatisfactory due to difficulties in obtaining large electron transparent areas, reproducible results, adequate solution lifetimes, and contamination free sample surfaces. In addition, there are the inherent health hazards associated with the use of CN solutions. Various attempts to develop noncyanic methods of electropolishing specimens for electron microscopy have not been successful in that the specimen quality problems encountered with the CN solutions have also existed in the previously proposed non-cyanic methods.The technique we describe allows us to jet polish high quality silver and silver alloy microscope specimens with consistant reproducibility and without the use of CN salts.The solution is similar to that suggested by Myschoyaev et al. It consists, in order of mixing, 115ml glacial actic acid (CH3CO2H, specific wt 1.04 g/ml), 43ml sulphuric acid (H2SO4, specific wt. g/ml), 350 ml anhydrous methyl alcohol, and 77 g thiourea (NH2CSNH2).


Author(s):  
A. V. Crewe ◽  
J. Wall ◽  
L. M. Welter

A scanning microscope using a field emission source has been described elsewhere. This microscope has now been improved by replacing the single magnetic lens with a high quality lens of the type described by Ruska. This lens has a focal length of 1 mm and a spherical aberration coefficient of 0.5 mm. The final spot size, and therefore the microscope resolution, is limited by the aberration of this lens to about 6 Å.The lens has been constructed very carefully, maintaining a tolerance of + 1 μ on all critical surfaces. The gun is prealigned on the lens to form a compact unit. The only mechanical adjustments are those which control the specimen and the tip positions. The microscope can be used in two modes. With the lens off and the gun focused on the specimen, the resolution is 250 Å over an undistorted field of view of 2 mm. With the lens on,the resolution is 20 Å or better over a field of view of 40 microns. The magnification can be accurately varied by attenuating the raster current.


Author(s):  
L. Mulestagno ◽  
J.C. Holzer ◽  
P. Fraundorf

Due to the wealth of information, both analytical and structural that can be obtained from it TEM always has been a favorite tool for the analysis of process-induced defects in semiconductor wafers. The only major disadvantage has always been, that the volume under study in the TEM is relatively small, making it difficult to locate low density defects, and sample preparation is a somewhat lengthy procedure. This problem has been somewhat alleviated by the availability of efficient low angle milling.Using a PIPS® variable angle ion -mill, manufactured by Gatan, we have been consistently obtaining planar specimens with a high quality thin area in excess of 5 × 104 μm2 in about half an hour (milling time), which has made it possible to locate defects at lower densities, or, for defects of relatively high density, obtain information which is statistically more significant (table 1).


Author(s):  
C. O. Jung ◽  
S. J. Krause ◽  
S.R. Wilson

Silicon-on-insulator (SOI) structures have excellent potential for future use in radiation hardened and high speed integrated circuits. For device fabrication in SOI material a high quality superficial Si layer above a buried oxide layer is required. Recently, Celler et al. reported that post-implantation annealing of oxygen implanted SOI at very high temperatures would eliminate virtually all defects and precipiates in the superficial Si layer. In this work we are reporting on the effect of three different post implantation annealing cycles on the structure of oxygen implanted SOI samples which were implanted under the same conditions.


Author(s):  
Judith M. Brock ◽  
Max T. Otten ◽  
Marc. J.C. de Jong

A Field Emission Gun (FEG) on a TEM/STEM instrument provides a major improvement in performance relative to one equipped with a LaB6 emitter. The improvement is particularly notable for small-probe techniques: EDX and EELS microanalysis, convergent beam diffraction and scanning. The high brightness of the FEG (108 to 109 A/cm2srad), compared with that of LaB6 (∼106), makes it possible to achieve high probe currents (∼1 nA) in probes of about 1 nm, whilst the currents for similar probes with LaB6 are about 100 to 500x lower. Accordingly the small, high-intensity FEG probes make it possible, e.g., to analyse precipitates and monolayer amounts of segregation on grain boundaries in metals or ceramics (Fig. 1); obtain high-quality convergent beam patterns from heavily dislocated materials; reliably detect 1 nm immuno-gold labels in biological specimens; and perform EDX mapping at nm-scale resolution even in difficult specimens like biological tissue.The high brightness and small energy spread of the FEG also bring an advantage in high-resolution imaging by significantly improving both spatial and temporal coherence.


Author(s):  
Yoshichika Bando ◽  
Takahito Terashima ◽  
Kenji Iijima ◽  
Kazunuki Yamamoto ◽  
Kazuto Hirata ◽  
...  

The high quality thin films of high-Tc superconducting oxide are necessary for elucidating the superconducting mechanism and for device application. The recent trend in the preparation of high-Tc films has been toward “in-situ” growth of the superconducting phase at relatively low temperatures. The purpose of “in-situ” growth is to attain surface smoothness suitable for fabricating film devices but also to obtain high quality film. We present the investigation on the initial growth manner of YBCO by in-situ reflective high energy electron diffraction (RHEED) technique and on the structural and superconducting properties of the resulting ultrathin films below 100Å. The epitaxial films have been grown on (100) plane of MgO and SrTiO, heated below 650°C by activated reactive evaporation. The in-situ RHEED observation and the intensity measurement was carried out during deposition of YBCO on the substrate at 650°C. The deposition rate was 0.8Å/s. Fig. 1 shows the RHEED patterns at every stage of deposition of YBCO on MgO(100). All the patterns exhibit the sharp streaks, indicating that the film surface is atomically smooth and the growth manner is layer-by-layer.


Sign in / Sign up

Export Citation Format

Share Document