scholarly journals Aeromagnetic and electrical resistivity mapping for groundwater development around Ilesha schist belt, southwestern Nigeria

Author(s):  
Cyril Chibueze Okpoli ◽  
Blessing omobolanle Akinbulejo

AbstractAeromagnetic and vertical electrical sounding around Ijano, southwestern Nigeria, was investigated for groundwater potential. Aeromagnetic dataset and vertical electrical sounding were acquired and used to investigate the study area. Oasis Montaj, Microsoft Excel and Arc GIS were used to present the results in maps, images and profiles. In order to map out the geological structures of the study area, magnetic image enhancing filters applied to the total magnetic intensity using Geosoft (Oasis Montaj) are reduction to equator, vertical derivative, total horizontal derivative and upward continuation. These filters helped define the lithological boundaries, geological structures, faults, folds and contacts. The lineament of aeromagnetic map was generated from derived field intensity gradients and solutions of Euler deconvolution carried out on the aeromagnetic data using structural index of 0.5 and 1. The processed image shows the lineaments trends majorly towards NE–SW directions. From these combined results of the study area, consistent aeromagnetic lineament map was generated showing the probable positions and trends of the suspected fractured/faulted zone as well as other basement structures. Hydro-lineament density maps based on lineament were produced from the generalized structure trends in the area. The result from the depth sounding data interpretation indicates three curve types which are H, HA and KH, where curve type H has the highest occurrence. The results from the vertical electrical sounding data revealed that the areas with the highest hydro-lineament density are good for groundwater prospect and development. The study has led to the delineation of areas where groundwater occurrences are most promising for sustainable supply, suggesting that an area with high concentrations of lineament density has a high tendency for groundwater prospecting. The results from the study show that the aeromagnetic technique is capable of extracting lineament trends in an inaccessible tropical forest.

Author(s):  
Adebo A. Babatunde ◽  
Ilugbo Stephen Olubusola ◽  
Oladetan Folorunso Emmanuel

A geoelectric investigation of groundwater prospect at Omitogun Estate, along Benin/Ilesha express way Akure, within the basement complex of southwestern Nigeria was carried out with a view to providing information on the geoelectric characteristic of the subsurface sequence, bedrock topography, subsurface structural features and their hydrogeologic significance, in order to identify aquifer units and determine possible areas for groundwater potential zones. The study involved the use of Schlumberger vertical electrical sounding data at thirty (30) stations. The vertical electrical sounding data presented as field curves were interpreted quantitatively by partial curve matching method and computer iteration technique. Fracture resistivity map, aquifer resistivity map, aquifer thickness map and overburden thickness map were generated from the results. Groundwater potential map was also generated from the integration of these maps using multi-criteria decision analysis (MCDA). The study area has been classified into low, medium, high groundwater potential zones and the results from well data across the entire study area were used to validate the accuracy of the groundwater potential map. From the results obtained, it could be concluded that the study area is generalized to be of low groundwater potential.  


2020 ◽  
Vol 24 (7) ◽  
pp. 1209-1215
Author(s):  
A.S. Salami ◽  
E.M. Babafemi

Electrical resistivity methods using dipole-dipole and Schlumberger configurations of Vertical Electrical Sounding (VES) were carried out to evaluate the near-surface structural and lithological features suitable for groundwater development in parts of Igarra, Southwestern Nigeria. Two profiles with lengths of greater than 350m were carried out. A total of fifteen sounding locations along the profile lines were occupied. Dipole-dipole data were interpreted using DiprofWin software while interpretation of the VES data followed two stages of qualitative and quantitative data  interpretation using Resist software. Dipole-dipole interpretation results indicate the occurrence of local fractures while VES interpretation results reveal the typical basement rock profile ranging from topsoil, lateritic sand, weathered front, fractured to fresh basement. The significant variations in terms of persistence and thicknesses of these basement vertical rock profiles were revealed by the geoelectrical correlation panels, which indicate typical basement inhomogeneities over short distances. The local structural domains, the weathered front (where thick) and the fractured basement are demonstrably potential sources of groundwater, at least for domestic and small scale enterprises in this part of Igarra. Keywords: 2-D Pseudosection, Dipole-dipole, Fracture Basement, Vertical Electrical Sounding


Author(s):  
O. E. Odeyemi ◽  
O. M. Odeyemi ◽  
S. A. Owolabi ◽  
E. A. Mamukuyomi ◽  
R. A. Salako

Owing to fast increase in number of staff and students of Joseph Ayo Babalola University, Ikeji Arakeji, Southwestern Nigeria, it is therefore very important to carry out this research in order to recommend the actual locations where boreholes can be sunk for good potential yields of groundwater when the time comes. The aim of this research is to carry out vertical electrical sounding geophysical survey at study area with a view to determining good aquifers that are good for the accumulation of groundwater. The study area is located between latitude 0820225 m to 0820345 m (UTM) Northings and longitude 717320 m to 717450 m (UTM) Eastings. Schlumberger electrode array was employed for the study using Ohmega Resistivity meter for the data acquisition. The geoelectric survey of the study area comprised of twelve vertical electrical soundings, with maximum current electrode spacing (AB) of 100 m. The modeled curves are mainly KH-type. The geoelectric sections generated from the sounding curves revealed 4 major layers earth models. The topsoil is made up of clay, clayey sand/lateritic sand with resistivity and thicknesses varying from 54.7 – 210.1ohm-m and 0.2 –0.8m respectively. The second layer is the lateritic clay with resistivities and thicknesses varying from 334 – 963ohm-m and 1.5 – 10.8m respectively. The third layer constitutes the clay / sandy fractured quartzite and it serves as the aquifer unit. The resistivity values lie between 71.7 and 498 ohm-m while the thicknesses vary from 2.1 – 76.3 m. The fourth layer is the fractured/presumably fresh basement bedrock with the resistivity varying from 1879 – 13991.8 ohm-m. Areas characterized with fractured basement of low resistivity with appreciable thickness are therefore recommended for the siting of boreholes. It is concluded that the vertical electrical sounding points of the study area are good aquifers for groundwater accumulation.


2021 ◽  
Vol 5 (2) ◽  
pp. 59-66
Author(s):  
Kazeem O.Olomo ◽  
Oluwatoyin K. Olaleye ◽  
Temitayo O. Ale ◽  
Michael T. Asubiojo ◽  
Oluyemi E. Faseki

Assessment of groundwater potential of Iperindo area, Southwestern Nigeria was conducted by mapping spatial distribution of groundwater availability within the area and consequently locating areas of groundwater reserve to serve the community and its environs. This was achieved by integrating geophysical techniques involving landsat ETM-7 satellite data, aeromagnetic data, VLF-EM and electrical resistivity methods to delineate subsurface structures, understand the direction of groundwater flow, and detect the depth to groundwater aquifer. The result of landsat and aeromagnetic revealed some lineament intersection approximately NE-SW direction and interpreted to be potential sites for groundwater development. VLF-EM revealed geologic structures of significant hydrogeological importance at depths of 40 m to 200 m. Vertical electrical sounding (VES) confirmed high groundwater prospect in the areas with estimated depth to water table between 30 m and 100 m. The integrated results of the study revealed adequate groundwater spatial distribution for effective groundwater development in the area.


2017 ◽  
Vol 15 (1) ◽  
pp. 70-81
Author(s):  
V MAKINDE ◽  
A O ERUOLA ◽  
S A GANIYU ◽  
O T OLURIN ◽  
O O ADELEKE ◽  
...  

Evaluation of groundwater potential in Odeda Local Government Area, Ogun State, Southwestern Nigeria, has been carried out in this study using Vertical Electrical Sounding method. The study area is underlain by Precambrian Basement Complex rocks of Southwestern Nigeria. These rocks are inher-ently characterized by low porosity and permeability. The interpretation of thirty (30) vertical electrical sounding (VES) conducted using the Schlumberger electrode array shows four geo-electric layers in the subsurface within the study area. The overburden thickness varies from 5.9 to 39 m across the study area. This was used to prepare the groundwater potential map which assisted in the zoning of the area into low, medium and high groundwater potential zones. The study showed that about 60% of the study area falls within the low/medium rated groundwater potential zone while the remaining 40% constituted the high groundwater potential zone. Hence, the groundwater potential rating of the area is generally low.


2020 ◽  
Vol 5 (2) ◽  
Author(s):  
Olayiwola G Olaseeni ◽  
Ajibola Oyebamiji ◽  
Oluwaseun Olaoye ◽  
Bosede Ojo ◽  
Ayokunle Akinlalu

This study aimed at evaluating the potential for groundwater development in the eastern part of Ado-Ekiti, Southwestern Nigeria using Vertical Electrical Sounding (VES). Data were acquired with ABEM SAS 300 and processed through partial curve matching techniques and assisted with 1-D forward modelling. Geoelectric parameters were determined from the VES interpreted result. Seven (7) different VES type curves (H, A, HA, KH, HK, QH and HKH) indicating inhomogeneity of the subsurface layer beneath the study area were observed. Weathered layer resistivity map having values ranging from 3.2 – 272 Ωm, overburden thickness of value vary between 0 and 28m and  bedrock relief values range from 360 – 480 m were delineated. It was estimated from the result that the northwestern and southeastern part which constituted about 15%of the study area possess high groundwater potential while the remaining 85% of the study area exhibit low/moderate potentials for yielding substantial water. Hence, the groundwater potential rating of the area was considered generally low.Keywords- Geoelectric, Groundwater potential, Overburden thickness, Vertical Electrical Sounding


2021 ◽  
Vol 25 (2) ◽  
pp. 233-238
Author(s):  
A. Ojo ◽  
E. Babafemi ◽  
E. Faleye ◽  
O. Shado

This work is an attempt to combine dipole-dipole profiling and vertical electrical sounding techniques of electrical resistivity methods to investigate the groundwater potential within the premises of a 3-star hotel facility in Osogbo, Nigeria by delineating the geoelectric layers, delineating the low resistivity layers, determining the lithologies and hence, delineating the groundwater bearing zones. The five vertical electrical sounding data were collected along two pre-surveyed dipole-dipole traverses at right angle to each other beside the fences of the premises using the ABEM SAS 300c terrameter. The observed data were interpreted quantitatively using curve matching and computer-assisted iteration method using the WinResist and Dipro software. The results of the inversion show that the lithology comprises of the top soil and an intermittent sequence of sand and lateritic clay having varying resistivity and thickness. The aquiferous layer was observed to be located at a depth of 23 m to 25 m due to the low resistivity and high thickness of the aquiferous layer. The result of the 2-D imaging closely correlates with the result of the vertical electrical sounding. Thus, combining these techniques in groundwater investigation has achieved similar result as the Werner technique and has reduced ambiguity and error in positioning for drilling. Keywords: Resistivity, Groundwater Exploration, Dipole-Dipole


2020 ◽  
Vol 4 (2) ◽  
pp. 99-102
Author(s):  
Johnson C. Ibuot ◽  
Moses M. M. Ekpa ◽  
Doris O. Okoroh ◽  
Aniefiok S. Akpan Emmanuel T. Omeje

Geoelectric survey employing Vertical Electrical Sounding (VES) was carried out in order to assess the groundwater repositories. A total of seven soundings were obtained with their layer resistivity, thickness and depth within the maximum electrode separation. The geoelectric parameters obtained were used to estimate the Dar-Zarrouk parameters (longitudinal conductance and transverse resistance), hydraulic conductivity and transmissivity. The result shows the aquifer resistivity ranging from 77.14 to 784.76 Ωm, with thickness ranging from 28.78 to 80.04 m. The longitudinal conductance have values ranging from 0.071 to 0.825 Ω-1 while the values of hydraulic conductivity and transmissivity range from 1.087 to 5.881 m/day and 60.180 to 374.031 𝑚2/day respectively. The contour maps generated show the variation of these parameters across the subsurface, and areas with poor protective capacity were delineated. The results also delineate the groundwater potential of the study area as moderate, while the corrosivity rating indicates non-corrosive and slightly corrosive.


Sign in / Sign up

Export Citation Format

Share Document