scholarly journals Magnetized Micropillar-Enabled Wearable Sensors for Touchless and Intelligent Information Communication

2021 ◽  
Vol 13 (1) ◽  
Author(s):  
Qian Zhou ◽  
Bing Ji ◽  
Fengming Hu ◽  
Jianyi Luo ◽  
Bingpu Zhou

AbstractThe wearable sensors have recently attracted considerable attentions as communication interfaces through the information perception, decoding, and conveying process. However, it is still challenging to obtain a sensor that can convert detectable signals into multiple outputs for convenient, efficient, cryptic, and high-capacity information transmission. Herein, we present a capacitive sensor of magnetic field based on a tilted flexible micromagnet array (t-FMA) as the proposed interaction interface. With the bidirectional bending capability of t-FMA actuated by magnetic torque, the sensor can recognize both the magnitude and orientation of magnetic field in real time with non-overlapping capacitance signals. The optimized sensor exhibits the high sensitivity of over 1.3 T−1 and detection limit down to 1 mT with excellent durability. As a proof of concept, the sensor has been successfully demonstrated for convenient, efficient, and programmable interaction systems, e.g., touchless Morse code and Braille communication. The distinguishable recognition of the magnetic field orientation and magnitude further enables the sensor unit as a high-capacity transmitter for cryptic information interaction (e.g., encoded ID recognition) and multi-control instruction outputting. We believe that the proposed magnetic field sensor can open up a potential avenue for future applications including information communication, virtual reality device, and interactive robotics.

2019 ◽  
Vol 16 (04) ◽  
pp. 1950019
Author(s):  
Ming Xu ◽  
Changlin Han ◽  
Hui Min Lu ◽  
Junhao Xiao ◽  
Jingsheng Tang ◽  
...  

Due to the extremely weak intensity of the biomagnetic field and the serious interference from the environmental magnetic field, the detection of the biomagnetic field becomes such challenging work. After analyzing the deficiencies in the current biomagnetic field sensors, this paper proposes and realizes a high-sensitivity magnetic field sensor, based on the giant magneto-impedance (GMI) effect. Taking advantage of the miniaturized magnetic probe, the multistage multiple amplification and the multiband interference suppression, our sensor mainly makes three achievements: the pT level magnetic resolution, the ability to detect the muscle magnetic field without the magnetic shielding and the resistibility to a small-range wobbling in the state of working, which makes it possible to detect the biomagnetic field by wearable sensors under natural conditions.


1994 ◽  
Vol 144 ◽  
pp. 21-28 ◽  
Author(s):  
G. B. Gelfreikh

AbstractA review of methods of measuring magnetic fields in the solar corona using spectral-polarization observations at microwaves with high spatial resolution is presented. The methods are based on the theory of thermal bremsstrahlung, thermal cyclotron emission, propagation of radio waves in quasi-transverse magnetic field and Faraday rotation of the plane of polarization. The most explicit program of measurements of magnetic fields in the atmosphere of solar active regions has been carried out using radio observations performed on the large reflector radio telescope of the Russian Academy of Sciences — RATAN-600. This proved possible due to good wavelength coverage, multichannel spectrographs observations and high sensitivity to polarization of the instrument. Besides direct measurements of the strength of the magnetic fields in some cases the peculiar parameters of radio sources, such as very steep spectra and high brightness temperatures provide some information on a very complicated local structure of the coronal magnetic field. Of special interest are the results found from combined RATAN-600 and large antennas of aperture synthesis (VLA and WSRT), the latter giving more detailed information on twodimensional structure of radio sources. The bulk of the data obtained allows us to investigate themagnetospheresof the solar active regions as the space in the solar corona where the structures and physical processes are controlled both by the photospheric/underphotospheric currents and surrounding “quiet” corona.


Author(s):  
Xue-Peng Jin ◽  
Hong-Zhi Sun ◽  
Shuo-Wei Jin ◽  
Wan-Ming Zhao ◽  
Jing-Ren Tang ◽  
...  

2016 ◽  
Vol 62 (11) ◽  
pp. 944-952 ◽  
Author(s):  
Lotfi Mhamdi ◽  
Nejib Mhamdi ◽  
Naceur Mhamdi ◽  
Philippe Lejeune ◽  
Nicole Jaffrezic ◽  
...  

This preliminary study focused on the effect of exposure to 0.5 T static magnetic fields on Escherichia coli adhesion and orientation. We investigated the difference in bacterial adhesion on the surface of glass and indium tin oxide-coated glass when exposed to a magnetic field either perpendicular or parallel to the adhesion surface (vectors of magnetic induction are perpendicular or parallel to the adhesion surface, respectively). Control cultures were simultaneously grown under identical conditions but without exposure to the magnetic field. We observed a decrease in cell adhesion after exposure to the magnetic field. Orientation of bacteria cells was affected after exposure to a parallel magnetic field. On the other hand, no effect on the orientation of bacteria cells was observed after exposure to a perpendicular magnetic field.


2014 ◽  
Vol 32 (10) ◽  
pp. 1207-1216 ◽  
Author(s):  
P. Janhunen

Abstract. Plasma brake is a thin, negatively biased tether that has been proposed as an efficient concept for deorbiting satellites and debris objects from low Earth orbit. We simulate the interaction with the ionospheric plasma ram flow with the plasma-brake tether by a high-performance electrostatic particle in cell code to evaluate the thrust. The tether is assumed to be perpendicular to the flow. We perform runs for different tether voltage, magnetic-field orientation and plasma-ion mass. We show that a simple analytical thrust formula reproduces most of the simulation results well. The interaction with the tether and the plasma flow is laminar (i.e. smooth and not turbulent) when the magnetic field is perpendicular to the tether and the flow. If the magnetic field is parallel to the tether, the behaviour is unstable and thrust is reduced by a modest factor. The case in which the magnetic field is aligned with the flow can also be unstable, but does not result in notable thrust reduction. We also correct an error in an earlier reference. According to the simulations, the predicted thrust of the plasma brake is large enough to make the method promising for low-Earth-orbit (LEO) satellite deorbiting. As a numerical example, we estimate that a 5 km long plasma-brake tether weighing 0.055 kg could produce 0.43 mN breaking force, which is enough to reduce the orbital altitude of a 260 kg object mass by 100 km over 1 year.


2006 ◽  
Vol 129 (4) ◽  
pp. 423-428 ◽  
Author(s):  
John R. Lloyd ◽  
Miquel O. Hayesmichel ◽  
Clark J. Radcliffe

Magnetorheological (MR) fluids change their physical properties when subjected to a magnetic field. As this change occurs, the specific values of the physical properties are a function of the fluid’s time-varying organization state. This results in a nonlinear, hysteretic, time-varying fluid property response to direct magnetic field excitation. Permeability, resistivity and permittivity changes of MR fluid were investigated and their suitability to indicate the organizational state of the fluid, and thus other transport properties, was determined. High sensitivity of permittivity and resistivity to particle organization and applied field was studied experimentally. The measurable effect of these material properties can be used to implement an MR fluid state sensor.


Sign in / Sign up

Export Citation Format

Share Document