Push-Out Test on Low-Density Concrete Filled Stiffened Steel Tubular Columns

Author(s):  
S. Sindhuja ◽  
P. Bhuvaneshwari
2018 ◽  
Vol 9 (2) ◽  
pp. 147-160 ◽  
Author(s):  
Peter Schaumann ◽  
Inka Kleibömer

Purpose This paper deals with experimental and numerical investigations of the composite behaviour within concrete-filled tubular columns with embedded massive steel core (CFTES columns). As the inner profile provides the main load-bearing capacity, the load introduction and transfer is of particular interest for the structural detailing of CFTES columns. Currently, no specific design regulations are available – neither for room temperature nor fire design. The presented investigations provide a basis for design recommendations and numerical approaches on reliable shear stresses. Design/methodology/approach Three series of push-out tests at room temperature and high temperatures are analysed in terms of ultimate shear strength, bond strength and shear strength-displacement-curve shape. The test parameters involve the steel core diameter and concrete cover, applying normal strength steel and concrete. Furthermore, a three-dimensional finite element model of the push-out tests is set up in Abaqus. The model implies temperature-dependent contact properties derived from the experimental tests using the cohesive behaviour method. Findings The test data reveal a distinctive reduction in both ultimate shear and bond strength for high temperatures. For high temperatures, the thermal expansion coefficients dominate the composite behaviour. Using the 3D numerical model and applying a temperature-dependent joint stiffness, maximum shear stress criterion and damage evolution, the observed composite behaviour can be described in a realistic manner. Originality/value The presented experimental investigations are unique, both concerning the investigated column type and performing push-out tests at high temperatures. For the first time, a temperature-dependent reduction of capable shear stresses is identified, which is crucial for the design of structural components.


2018 ◽  
Vol 204 ◽  
pp. 634-644 ◽  
Author(s):  
Kaidi Peng ◽  
Tao Yu ◽  
Muhammad N.S. Hadi ◽  
Le Huang

2019 ◽  
Vol 23 (6) ◽  
pp. 1224-1237 ◽  
Author(s):  
Xiushu Qu ◽  
Fei Huang ◽  
Guojun Sun ◽  
Qi Liu ◽  
Hui Wang

In a previous study, 17 rectangular concrete-filled steel tubular columns were tested using a push-out test method to examine the interfacial bond behaviour. In this study, these specimens were subjected to axial compressive tests to study the effects of interfacial damage on the ultimate axial compressive capacity. The variations in both the load–axial displacement curves and load–strain curves were recorded and then compared to study the influences of both the steel tube fabrication method and the D/ B ratio on the axial load–carrying capacity. The axial compressive behaviour of rectangular concrete-filled steel tubular columns with no interfacial damage was then studied using a numerical analysis method. The contact stress distribution along the length and width of the face and at the height of the interface was obtained and discussed. In addition, the ultimate axial compressive capacity of rectangular concrete-filled steel tubular columns with no interfacial damage was calculated using the formulas from three international codes. The influence of interfacial damage on the axial compressive bearing capacity of a rectangular concrete-filled steel tubular column was discussed through a comparison of the results of the numerical simulation, formula calculation and experiments. The influence of the interfacial gaps caused by the push-out tests on the axial bearing capacity of the concrete-filled steel tubular columns can be ignored, because the core concrete was not destroyed and the outside steel tube can provide a sufficient constraint force on the concrete when the two materials yielded. Finally, the influences of the gap type and size on the bearing capacity were discussed.


Author(s):  
P.J. Killingworth ◽  
M. Warren

Ultimate resolution in the scanning electron microscope is determined not only by the diameter of the incident electron beam, but by interaction of that beam with the specimen material. Generally, while minimum beam diameter diminishes with increasing voltage, due to the reduced effect of aberration component and magnetic interference, the excited volume within the sample increases with electron energy. Thus, for any given material and imaging signal, there is an optimum volt age to achieve best resolution.In the case of organic materials, which are in general of low density and electric ally non-conducting; and may in addition be susceptible to radiation and heat damage, the selection of correct operating parameters is extremely critical and is achiev ed by interative adjustment.


Author(s):  
L. Mulestagno ◽  
J.C. Holzer ◽  
P. Fraundorf

Due to the wealth of information, both analytical and structural that can be obtained from it TEM always has been a favorite tool for the analysis of process-induced defects in semiconductor wafers. The only major disadvantage has always been, that the volume under study in the TEM is relatively small, making it difficult to locate low density defects, and sample preparation is a somewhat lengthy procedure. This problem has been somewhat alleviated by the availability of efficient low angle milling.Using a PIPS® variable angle ion -mill, manufactured by Gatan, we have been consistently obtaining planar specimens with a high quality thin area in excess of 5 × 104 μm2 in about half an hour (milling time), which has made it possible to locate defects at lower densities, or, for defects of relatively high density, obtain information which is statistically more significant (table 1).


Author(s):  
Dean A. Handley ◽  
Cynthia M. Arbeeny ◽  
Larry D. Witte

Low density lipoproteins (LDL) are the major cholesterol carrying particles in the blood. Using cultured cells, it has been shown that LDL particles interact with specific surface receptors and are internalized via a coated pit-coated vesicle pathway for lysosomal catabolism. This (Pathway has been visualized using LDL labeled to ferritin or colloidal gold. It is now recognized that certain lysomotropic agents, such as chloroquine, inhibit lysosomal enzymes that degrade protein and cholesterol esters. By interrupting cholesterol ester hydrolysis, chloroquine treatment results in lysosomal accumulation of cholesterol esters from internalized LDL. Using LDL conjugated to colloidal gold, we have examined the ultrastructural effects of chloroquine on lipoprotein uptake by normal cultured fibroblasts.


Author(s):  
Ian M. Anderson

B2-ordered iron aluminide intermetallic alloys exhibit a combination of attractive properties such as low density and good corrosion resistance. However, the practical applications of these alloys are limited by their poor fracture toughness and low room temperature ductility. One current strategy for overcoming these undesirable properties is to attempt to modify the basic chemistry of the materials with alloying additions. These changes in the chemistry of the material cannot be fully understood without a knowledge of the site-distribution of the alloying elements. In this paper, the site-distributions of a series of 3d-transition metal alloying additions in B2-ordered iron aluminides are studied with ALCHEMI.A series of seven alloys of stoichiometry Fe50AL45Me5, with Me = {Ti, V, Cr, Mn, Co, Ni, Cu}, were prepared with identical heating cycles. Microalloying additions of 0.2% B and 0.1% Zr were also incorporated to strengthen the grain boundaries, but these alloying additions have little influence on the matrix chemistry and are incidental to this study.


Author(s):  
C. W. Price ◽  
E. F. Lindsey ◽  
R. M. Franks ◽  
M. A. Lane

Diamond-point turning is an efficient technique for machining low-density polystyrene foam, and the surface finish can be substantially improved by grinding. However, both diamond-point turning and grinding tend to tear and fracture cell walls and leave asperities formed by agglomerations of fragmented cell walls. Vibratoming is proving to be an excellent technique to form planar surfaces in polystyrene, and the machining characteristics of vibratoming and diamond-point turning are compared.Our work has demonstrated that proper evaluation of surface structures in low density polystyrene foam requires stereoscopic examinations; tilts of + and − 3 1/2 degrees were used for the stereo pairs. Coating does not seriously distort low-density polystyrene foam. Therefore, the specimens were gold-palladium coated and examined in a Hitachi S-800 FESEM at 5 kV.


Sign in / Sign up

Export Citation Format

Share Document