scholarly journals Experimental Investigation of Reactive-Inert Particulate Matter Detachment from Metal Fibres at Low Flow Velocities and Different Gas Temperatures

Author(s):  
Julian Zoller ◽  
Amin Zargaran ◽  
Kamil Braschke ◽  
Jörg Meyer ◽  
Uwe Janoske ◽  
...  

Abstract The detachment of particle structures from single fibres in gas flow has been investigated only for inert particle structures yet. This study investigates the detachment of particle structures containing reactive components. These reactive components disappear during the reaction and enhance detachment at low flow velocities. Soot was used as the reactive component and glass spheres as the inert component of the particle structure. The soot disappears due to combustion with oxygen leaving only the glass spheres on the fibre. Without reaction, the detachment phenomenon was observed at superficial flow velocities above 1.9 m/s and with reaction at 0.5 m/s. This shows that reacting and disappearing components of the particle structure can enhance detachment.

Sensors ◽  
2021 ◽  
Vol 21 (12) ◽  
pp. 4025
Author(s):  
Matej Njegovec ◽  
Simon Pevec ◽  
Denis Donlagic

This paper presents a short response time, all-silica, gas-flow-velocity sensor. The active section of the sensor consists of a 16 µm diameter, highly optically absorbing micro-wire, which is heated remotely by a 980 nm light source. The heated microwire forms a Fabry–Perot interferometer whose temperature is observed at standard telecom wavelengths (1550 nm). The short response time of the sensor allows for different interrogation approaches. Direct measurement of the sensor’s thermal time constant allowed for flow-velocity measurements independent of the absolute heating power delivered to the sensor. This measurement approach also resulted in a simple and cost-efficient interrogation system, which utilized only a few telecom components. The sensor’s short response time, furthermore, allowed for dynamic flow sensing (including turbulence detection). The sensor’s bandwidth was measured experimentally and proved to be in the range of around 22 Hz at low flow velocities. Using time constant measurement, we achieved a flow-velocity resolution up to 0.006 m/s at lower flow velocities, while the resolution in the constant power configuration was better than 0.003 m/s at low flow velocities. The sensing system is constructed around standard telecommunication optoelectronic components, and thus suitable for a wide range of applications.


1998 ◽  
Vol 275 (4) ◽  
pp. H1138-H1147 ◽  
Author(s):  
Qiaobing Huang ◽  
Mac Wu ◽  
Cynthia Meininger ◽  
Katherine Kelly ◽  
Yuan Yuan

Platelet-activating factor (PAF) has been implicated in the pathogenesis of ischemic heart disease, reperfusion injury, and inflammatory reactions. Although neutrophils have been shown to primarily mediate PAF-induced microvascular dysfunction, the vasoactive effect of PAF and its neutrophil-dependent mechanism have not been directly and systematically studied in coronary resistance vessels. Therefore, the aim of this study was to examine the effects of PAF on coronary arteriolar function and neutrophil dynamics using an isolated and perfused microvessel preparation. Topical application of PAF to the vessels induced a dose-dependent decrease in the diameter but an increase in the apparent permeability coefficient of albumin. Disruption of the endothelium abolished the vasomotor response to PAF, and perfusion of neutrophils significantly augmented PAF-induced changes in vasomotor tone and permeability. Furthermore, the interaction between neutrophils and the endothelium was studied in the intact perfused coronary arterioles. Under control conditions, there were no adherent neutrophils observed in the vessels at varied intraluminal flow velocities. However, administration of PAF caused neutrophil adhesion to the endothelium of coronary arterioles at low flow velocities. Western blot analysis indicated that PAF upregulated the expression of intercellular adhesion molecule-1 in cultured coronary microvascular endothelial cells. Taken together, the results suggest that 1) PAF induces vasoconstriction and hyperpermeability in coronary arterioles via an endothelium-dependent and neutrophil-mediated mechanism, and 2) PAF is able to stimulate neutrophil adhesion in coronary arterioles under a condition of low flow rate.


Author(s):  
Dana Giacobbi ◽  
Stephanie Rinaldi ◽  
Christian Semler ◽  
Michael P. Pai¨doussis

This paper investigates the dynamics of a slender, flexible, aspirating cantilevered pipe, ingesting fluid at its free end and conveying it towards its clamped end. The problem is interesting not only from a fundamental perspective, but also because applications exist, notably in ocean mining [1]. First, the need for the present work is demonstrated through a review of previous research into the topic — spanning many years and yielding often contradictory results — most recently concluding that the system loses stability by flutter at relatively low flow velocities [2]. In the current paper, that conclusion is refined and expanded upon by exploring the problem in three ways: experimentally, numerically and analytically. First, air-flow experiments, in which the flow velocity of the fluid was varied and the frequency and amplitude of oscillation of the pipe were measured, were conducted using different elastomer pipes and intake shapes. Second, a fully-coupled Computational Fluid Dynamics (CFD) and Computational Structural Mechanics (CSM) model was developed in ANSYS in order to simulate experiments and corroborate experimental results. Finally, using an analytical approach, the existing linear equation of motion describing the system was significantly improved upon, and then solved via the Galerkin method in order to determine its stability characteristics. Heavily influenced by a CFD analysis, the proposed analytical model is different from previous ones, most notably because of the inclusion of a two-part fluid depressurization at the intake. In general, both the actual and numerical experiments suggest a first-mode loss of stability by flutter at relatively low flow velocities, which agrees with the results from the new analytical model.


2021 ◽  
Author(s):  
Sakethraman Mahalingam ◽  
Gavin Munro ◽  
Muhammad Arsalan ◽  
Victor Gawski

Abstract When the gas flow rate of a well significantly changes, the flow rate can fall below that of the operating range of a traditional fixed size Venturi meter, necessitating the replacement of the original meter with one of a smaller size. However, with an adjustable cone meter, the internal reconfiguration feature allows it to automatically switch from high operating flow range to low operating flow range and there is no requirement to disassemble the meter from the flow line assembly. Adjustable cone meters were designed, developed and tested at the wet-gas flow loop at National Engineering Laboratory in East Kilbride, Scotland. After calibrating the meter with dry nitrogen gas, the meter was tested with increasing amounts of liquid being injected into the flowline, upstream of the meter. The liquid caused the differential pressure measurement on the meter to over-read. Based on the differential pressure measurements under varying flow conditions, algorithms were developed to measure the dry gas and liquid fraction. The data obtained from the tests such as differential pressure, pressure, temperature, liquid density were used to build an over-reading model of the meter and a liquid fraction estimation model based on pressure loss ratio derived from an additional differential pressure measurement. The model was used to not only to quantify the gas and liquid flow rates but also the estimated error in each measurement. The measurements show that the Adjustable Cone meter is able to provide low uncertainty in both dry and wet gas conditions and offers a turndown ratio of up to 54:1 in dry gas conditions. In addition, the automatic adjustment of the meter from high flow to low flow positions avoids the need for manual intervention that involves additional risk and cost.


1998 ◽  
Vol 88 (1) ◽  
pp. 66-71 ◽  
Author(s):  
Hiromichi Bito ◽  
Yukako Ikeuchi ◽  
Kazuyuki Ikeda

Background Sevoflurane anesthesia is usually performed with fresh gas flow rates greater than 2 l/min due to the toxicity of compound A in rats and limited clinical experience with sevoflurane in low-flow systems. However, to reduce costs, it would be useful to identify ways to reduce compound A concentrations in low-flow sevoflurane anesthesia. This goal of this study was to determine if compound A concentrations can be reduced by using soda lime with water added. Methods Low-flow sevoflurane anesthesia (fresh gas flow of 1 l/min) was performed in 37 patients using soda lime with water added (perhydrated soda lime) or standard soda lime as the carbon dioxide (CO2) absorbent. The soda lime was not changed between patients, but rather was used until CO2 rebreathing occurred. The perhydrated soda lime was prepared by spraying 100 ml distilled water onto 1 kg fresh soda lime, and water was added only when a new bag of soda lime was placed into the canister. Compound A concentrations in the circle system, soda lime temperatures, inspired and end-tidal CO2 and end-tidal sevoflurane concentrations, and CO2 elimination by the patient were measured during anesthesia. Results Compound A concentrations were significantly lower for the perhydrated soda lime (1.9 +/- 1.8 ppm; means +/- SD) than for the standard soda lime (13.9 +/- 8.2 ppm). No differences were seen between the two types of soda lime with regard to the temperature of the soda lime, end-tidal sevoflurane concentrations, or CO2 elimination. Compound A concentration decreased with the total time of soda lime use for both types of soda lime. The CO2 absorption capacity was significantly less for perhydrated soda lime than for standard soda lime. Conclusions Compound A concentrations in the circuit can be reduced by using soda lime with water added. The CO2 absorption capacity of the soda lime is reduced by adding water to it, but this should not be clinically significant.