1965 ◽  
Vol 43 (1) ◽  
pp. 1-12
Author(s):  
W. A. M. COURTNEY ◽  
R. C. NEWELL

1. The rate of oxygen uptake by single specimens of Branchiostoma lanceolatum has been shown to vary considerably. Some animals in sealed vessels at 50° C. were able to utilize the oxygen linearly down to less than 20% of air saturation. Others ceased to absorb oxygen at high saturations while yet others displayed two different rates in a sequence starting initially with a high rate. 2. There are three possible rates of oxygen utilization, as well as a zero rate, for an animal at any temperature between 10 and 19° C. Animals in gravel exhibit only two rates at lower temperatures. 3. The slowest rate varies exponentially with temperature but the two faster rates show a rapid increase between 10 and 15° C. with little change outside this temperature range. 4. The effect of size and temperature on the increased oxygen uptake during the faster rates of respiration are discussed. It is suggested that ciliary activity of the pharynx could be associated with the extra oxygen utilization. 5. It has been found that there are three inhalant stream velocities, a fast, a slow and a zero rate with no intermediate rates. 6. Study of the isolated portions of the pharyngeal wall confirm that the fast inhalant current is set by the activity of all the cilia to give a feeding stream. The slow stream is set up by the lateral cilia, which continue to beat when the frontal cilia and most of the lateral cilia have been inhibited by lowered oxygen concentrations. 7. The lateral cilia have been shown to be under nervous control and to be inhibited by pressure on the pharyngeal bars. This mechanism depends on the presence of a connexion between the pharyngeal bars and the endostyle.


Memorias ◽  
2018 ◽  
pp. 58-66
Author(s):  
Johnny Valencia ◽  
Gerard Olivar ◽  
Johan Manuel Redondo ◽  
Danny Ibarra Vega ◽  
Carlos Peña Rincón

In this paper, we show the preliminary results in a proposed a model for the supply and demand of electricity in a domestic market based on system dynamics. Additionally, the model indicates piecewise smooth differential equations arising from the diagram of flows and levels, using dynamical systems theory for the study of the stability of the equilibrium points that have such a system. A bifurcation analysis approach is proposed to define and understand the complex behavior. Until now, no work has been reported related to this topic using bifurcations criteria. The growing interest in personal ways of self-generation using renewable sources can lead the national grid to a standstill and low investment in the system. However, it is essential to preserve the national network as a power supply support to domestic and enterprise demand. To understand this scenario, we include an analysis of zero-rate demand growth. Under this hypothesis, a none smooth bifurcation appears related to a policy which involves the variation of the capacity charge. As a first significant result, we found that it is possible to preserve the investments in the market since, through the capacity charge parameter, the system dynamics can be controlled. Then, from a business approach, it is necessary to know the effects of the capacity charge as the strategic policy in the system generation price scheme.


Author(s):  
O.V. Shinkareva

In this article, the peculiarities of applying the zero income tax rate of organizations by medical companies are considered. The requirements that, according to the Tax Code of the Russian Federation, must be fulfilled by medical organizations to impose the profit received at a rate of 0% are considered: the types of activities for which profit is subject at this rate, the presence of a certain percentage of medical personnel, restrictions on the number of employees and other restrictions. Listed are the types of reporting that should be additionally submitted by a medical organization that has expressed a desire to apply a zero rate, as well as the consequences of not submitting these documents. Features of voluntary transition to profit levying at a rate of 20% are shown, practical examples are given.


2019 ◽  
Vol 24 (1) ◽  
pp. 1-7 ◽  
Author(s):  
Holger Sudhoff ◽  
Hans Björn Gehl ◽  
Ercan Boga ◽  
Stefan Müller ◽  
Katharina Wilms ◽  
...  

Background: The insertion of the stapes piston into the vestibule provides the physical basis for a successful stapedotomy. In routine clinical practice, two different ways to handle prosthesis length are performed: (1) an individualized measurement of the stapes prosthesis length or (2) a standard prosthesis length for all cases. Objective: The objective of this study was to compare both ways of handling prosthesis length and the effect of these methods on insertional prosthesis depth. Material and Method: We retrospectively evaluated 39 patients after performing a stapedotomy for radiologically estimated vestibular stapes prosthesis insertion depth. The individual measured length data were hypothetically changed to a standard length of 4.75, 5, 5.25, and 5.5 mm, and the insertion depths were compared. Results: The individually measured prosthesis lengths led to an insertion depth between 0.2 and 1.6 mm (mean 0.74 mm). The ratio of insertion depth/vestibular depth was between 8 and 59.1% (mean 26.6%). The different assumed standard lengths led to different rates of the vestibulum positions and possible bony contacts at the vestibulum floor. Conclusion: The individual measurement led to a zero rate of the vestibulum positions of stapes prosthesis pistons with a low insertion depth/vestibular depth ratio.


1960 ◽  
Vol 15 (2) ◽  
pp. 225-228 ◽  
Author(s):  
John H. Knowles ◽  
William Newman ◽  
Wallace O. Fenn

At the end of a normal expiration the subject inhaled a given volume of gas mixtures containing different concentrations of CO2 in O2 from 5 to 17%. These were held in the lung for 3 and then again for 12 seconds and were then expired and analyzed. Analyses were made with an infrared analyzer and times were obtained from the graphical record. If the rate of change of CO2 tension is plotted against the mean CO2 tension a straight line results which passes through zero rate at the tension which equals the tension of CO2 in the mixed oxygenated venous blood. From the slope of this straight line it is possible to calculate the cardiac output if the lung volume and slope of the CO2 dissociation curve of the blood are known. Data are presented from 37 experiments on 10 subjects. The method is believed to be theoretically sound but has not been validated as a practical clinical method. Occasional erratic points were obtained, especially in untrained subjects. The standard error of the mean value for venous CO2 tension was 1.9 mm Hg. Submitted on July 13, 1959


2018 ◽  
Vol 20 (1) ◽  
Author(s):  
Max Gillman

Abstract The paper presents the welfare cost of inflation in a banking time economy that models exchange credit through a bank production approach. The estimate of welfare cost uses fundamental parameters of utility and production technologies. It is compared to a cash-only economy, and a [Lucas, Robert Jr. E. 2000. “Inflation and Welfare.” Econometrica 68 (2): 247–274.] shopping economy without leisure, as special cases. The paper estimates the welfare cost of a 10% inflation rate instead of zero, for comparison to other estimates, as well as the cost of a 2% inflation rate instead of a zero inflation rate. A zero rate is statutorily specified as the US inflation rate target in the 1978 Employment Act amendments. The paper provides a conservative welfare cost estimate of 2% inflation instead of zero at $33 billion a year. Estimates of the percent of government expenditure that can be financed through a 2% vs. zero inflation rate are also provided.


Author(s):  
R. C. Newell ◽  
H. R. Northcroft

The rate of cirral beat of Balanus balanoides is related to the logarithm of the body weight as an exponential function. In any one animal, there is little effect of temperature on cirral activity between 7·5° and 10° C. Between 10° and 20° C, however, there is a rapid increase in cirral beat with temperature followed by a fall at temperatures above 20° C.Balanus balanoides exhibits a fast, medium and zero rate of oxygen consumption. These rates of oxygen consumption correspond with (a) normal cirral beating, (b) ‘testing’ activity with no cirral movement, and (c) with the closure of the mantle cavity. Both of the possible levels of oxygen uptake are related to the logarithm of the body weight in a logarithmic fashion over the temperature range 7·5°–22·5° C. Temperature affects the two rates of oxygen consumption differently. In the slower rate (rate B) there is an increase in the rate of oxygen consumption between 7·5° and 14° C but there is no significant increase in the rate of oxygen consumption between 14° and 22·5 C°.


2005 ◽  
Vol 51 (2) ◽  
pp. 447-465 ◽  
Author(s):  
A.B. Wagner ◽  
V. Anantharam
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document