95/06411 Friction factor and Nusselt number in flat tubes with rounded edges

1995 ◽  
Vol 36 (6) ◽  
pp. 453
2017 ◽  
Vol 109 ◽  
pp. 461-479 ◽  
Author(s):  
Anil Kumar ◽  
Raj Kumar ◽  
Rajesh Maithani ◽  
Ranchan Chauhan ◽  
Muneesh Sethi ◽  
...  

2016 ◽  
Vol 78 (8-4) ◽  
Author(s):  
Chin Yung Shin ◽  
Normah Mohd-Ghazali

In this research, the trapezoidal shaped chevron plate heat exchanger (PHE) is simulated using computational fluid dynamics (CFD) software to determine its heat transfer capacity and friction factor. The PHE is modelled with chevron angles from 30° to 60°, and also the performances are compared with the plain PHE. The validation is done by comparing simulation result with published references using 30° trapezoidal chevron PHE. The Nusselt number and friction factor obtained from simulation model is plotted against different chevron angles. The Nusselt number and friction factor is also compared with available references, which some of the references used sinusoidal chevron PHE. The general pattern of Nusselt number and friction factor with increasing chevron angle agrees with the references. The heat transfer capacity found in current study is higher than the references used, and at the same time, the friction factor also increased. Besides this, it is also found that the counter flow configuration has better heat transfer capacity performance than the parallel flow configuration.


Author(s):  
Stephen A. Andrews ◽  
William D. E. Allan

An experiment was conducted on the effects of streamwise stagger on heat transfer and pressure drop in a pin-fin array. The data were analyzed so as to highlight how stagger could be used to design a pin fin array for the lowest possible pressure loss. Design of arrays for low pressure loss is important in electronics cooling applications. They require large amounts of heat to be extracted from fixed areas, using a minimum of power to do so. This analysis found that the minimum friction factor occurred at a streamwise stagger of approximately 12% of the range between fully inline and fully staggered. By fixing the pin diameter, varying the stagger resulted in a 63% reduction in friction factor with only a 18% reduction in the Nusselt number, based on the array footprint. Additionally, it was found that for a fixed Nusselt number, the pin diameter could vary within a finite range, with decreasing diameters permitting arrays with more efficient degrees of stagger which continued to carry the required heating/cooling load.


Author(s):  
Md. Islam ◽  
Z. Chong ◽  
S. Bojanampati

Various technologies have been developed to enhance flow mixing and heat transfer in order to develop an efficient compact heat exchanging devices. Vortex generators/turbulent promoters generate the vortices which reduce the boundary layer thickness and introduce the better mixing of the fluid to enhance the heat transfer. In this research experimental investigations have been carried out to study the effect of delta winglet vortex generator pairs on heat transfer and flow behavior. To generate longitudinal vortex flow, two pairs of the delta winglet vortex generators (DWVG) with the length of 10mm and winglet-pitch to tube-diameter ratio (PR = 4.8) are mounted on the inner wall of a circular tube. The DWVG pairs with two different winglet-height to tube-diameter ratios (Blockage ratio, BR = 0.1 and 0.2), three attack angles (α = 10°, 20°, 30°) and three spacings between leading edges (S = 10, 15 and 20mm) are studied. The experiments were conducted with DWVGs pairs for the air flow range of Reynolds numbers 5000–25000. The influence of the DWVGs on heat transfer and pressure drop was investigated in terms of the Nusselt number and friction factor. The experimental results indicate that DWVG pair in a tube results in a considerable enhancement in Nusselt number (Nu) with some pressure penalty. It is found that DWVG increases Nu up to 85% over the smooth tube. It is also observed that Nusselt number increases with Re, blockage ratio and attack angle. Friction factor decreases with Re but increases with blockage ratio, spacing and attack angle. And 30° DWVG pair with S = 20mm, BR = 0.2 gets the highest friction factor. The Highest thermal performance enhancement (TPE) was noticed for α = 10°, S = 20mm, BR = 0.2 for turbulent flows. To obtain qualitative information on the flow behavior and vortex structures, flow was visualized by laser sheet using smoke as a tracer supplied at the entrance of the test section. The generation and development of longitudinal vortices influenced by DWVG pairs were clearly observed.


Author(s):  
Shashank R Chaurasia ◽  
RM Sarviya

An experimental analysis has been carried out to investigate the thermal and friction factor characteristics of fluid flow in a tube with double strip helical screw tape (DS-HST) inserts with different values of twist ratio and compared with single strip helical screw tape inserts and plain tube. Water is used as a working fluid at different flow rates with constant heat flux conditions. CFD analysis is also carried out to visualize thermal and fluid flow characteristics of fluid flow in tube with inserts. Experimental results have showed that Nusselt number and friction factor have attained excellent enhancement with double strip helical screw tape inserts in the range of flow rates than single strip helical screw tape inserts at the value of twist ratio 1.5. Correlation is also developed for Nusselt number with a range of Reynolds number, twist ratio and number of strips. Moreover, the performance ratio has attained maximum value at twist ratio of 2.5 with high values of flow rate. It is concluded that DS-HST is able to attain enhancement in the efficiency of heat exchanger, causing a reduction in size for thermal applications.