THE ROLE OF FILAMENTOUS MICROORGANISMS IN ACTIVATED SLUDGE SETTLING

Author(s):  
Mesut Sezgin
1994 ◽  
Vol 30 (11) ◽  
pp. 159-169 ◽  
Author(s):  
Jiri Wanner

The paper briefly surveys topics covered by the IAWQ Specialist Group on Activated Sludge Population Dynamics. The activated sludge population dynamics has been formulated as a branch of water science and technology concerned with phenomena governing the relationships between activated sludge microorganisms and their functions. The characterization of organic pollution fractions in wastewaters according to their rate of biodegradation has been discussed and the role of wastewater as an inoculum stressed. The characterization of activated sludge biomass has been evaluated from two viewpoints: grouping according to metabolic abilities and identification and classification of activated sludge microorganisms. The basic selection mechanisms influencing the microbial composition of activated sludge have been described. The problems with activated sludge settling and thickening properties have been mentioned as a typical example of applied population dynamics research.


1994 ◽  
Vol 29 (7) ◽  
pp. 157-165 ◽  
Author(s):  
Gert Holm Kristensen ◽  
Per Elberg Jørgensen ◽  
Per Halkjær Nielsen

In 1989-91, a study was performed to investigate the settling characteristics of activated sludge in Danish treatment plants with biological nutrient removal. The study included three screening series on 38 treatment plants. Furthermore, the study included investigations during one year on seasonal variations in sludge settling characteristics at three treatment plants. The screening investigations were performed in November 1989 and May and September, 1990. Results showed that in the May-screening, 35-45% of the plants had a filament index of 2-2.5 or above, corresponding to a sludge volume index above 150 ml/g. When comparing data for diluted and non-diluted sludge volume indices, a SVI value of 150 ml/g seemed parallel to a DSVI of 110 ml/g. In the November- and September-screenings, some 30% of the plants had activated sludge showing a filament index in or above the critical area. Dominating filamentous microorganisms were found to be (in decreasing order): Microthrix parvicella, Type 0041, Type 021N, Type 0092, Type 0914, and Type 1851. A distinct variation over the year in sludge settling characteristics was found for the three plants. Sludge settling characteristics improved during summer, and deteriorated during winter. For activated sludge with a high content of filamentous microorganisms, the best parameter to follow the variations in sludge settling properties was the filament number. If the activated sludge concentration, the MLSS, varied significantly, the specific filament number was to be applied.


1988 ◽  
Vol 20 (4-5) ◽  
pp. 1-8 ◽  
Author(s):  
Jiri Wanner ◽  
Petr Grau

Behaviour of filamentous microorganisms under anaerobic, anoxic, and oxic conditions has been reviewed from the point of view of filamentous bulking in nutrient removal activated sludge systems. It was concluded that the growth of most filamentous microorganisms is considerably suppressed under anaerobic and anoxic conditions and that the filamentous bulking in nutrient removal systems is chiefly caused by the growth of filamentous microorganisms in oxic zones. The role of particulate substrate hydrolysis was also discussed and the necessity of compartmentalization of oxic zones was shown.


1994 ◽  
Vol 29 (7) ◽  
pp. 185-188 ◽  
Author(s):  
L. Cingolani ◽  
E. Ciccarelli ◽  
M. Cossignani ◽  
Q. Tornari ◽  
V. Scarlata

A study was made at nine papermill activated sludge treatment plants, affected by bulking phenomena, on the behaviour of filamentous microorganisms in connection with plant performances. In the sludge samples 24 organisms were identified, the most frequently observed being type 0041 and 0675. The principal causes of inconvenience, isolated through statistical analysis, were identified as low oxygenation, high load, low F/M, nutrient deficiency. Changes made in operating conditions improved bulking in some plants.


1980 ◽  
Vol 15 (1) ◽  
pp. 73-82 ◽  
Author(s):  
J.G. Henry ◽  
E.E. Salenieks

Abstract This study examined the effect of temperature on the settleabi1ity of activated sludge at various organic loading rates. Five completely mixed, bench-scale, activated sludge plants, operating under similar conditions at 5, 10 and 19°C, were continuously fed diluted, settled sewage supplemented with carbohydrate (sucrose). Hydraulic loading rates, MLSS and pH were maintained at constant levels during the experiments to eliminate these factors are variables. Dissolved oxygen was kept in excess of 3 mg/1 so that it would not be a limiting factor. Sludge Volume Indices (SVI ) and zone settling velocities were used to indicate changes in sludge settleability. Microscopic examination of the activated sludge indicated significant differences in the morphological features of filamentous microorganisms present at the two temperature extremes. At 19°C, the predominant forms were characterized by long curving trichomes, occasionally falsely branching, containing short cylindrical cells. At 5 °C, much smaller straight filaments, composed of long, narrow, rod-shaped cells appeared to be the principal microorganisms responsible for bulking. Various other filamentous forms were always present at each of the temperatures studied. Stirred sludge settling tests of moderately bulking sludges generally exhibited much higher settling velocities and lower SVI's than unstirred bulking samples. However, extremely filamentous bulking sludge exhibited comparable stirred and unstirred settling velocity and SVI values. The standard SVI test was found to be an inadequate indicator of the extent of bulking when trying to correlate the SVI failures from bench-scale performance with the results from continuous units. Lower temperature had no appreciable effect on COD removal efficiency as long as bulking did not cause a loss of solids in the effluent. However, results suggested that less than half the organic load could be accepted at 5°C, that could be handled at 19°C, before filamentous bulking occurred. A plot of loading versus temperature for various SVI's provided a visual indication of the safe loading limit below which bulking was unlikely to occur. The study clearly demonstrated that temperature can have a significant effect on sludge settleability.


1991 ◽  
Vol 23 (4-6) ◽  
pp. 899-905 ◽  
Author(s):  
Y. Matsuzawa ◽  
T. Mino

Activated sludge mixed cultures were cultivated with a glucose containing substrate in order to investigate the relationship between the feeding pattern (continuous or intermittent feeding) and the glycogen reservation capacity of activated sludge. An experimental method to measure the maximum capacity of glycogen reservation in the sludge was developed. Sludge with higher glycogen reservation capacity has an ability to synthesize glycogen faster, which ensures the higher glucose uptake. Therefore, sludge which has high glycogen reservation capacity becomes predominant in intermittently fed reactors. When the feeding pattern was changed from continuous feeding to intermittent feeding, a filamentous bacterium, Type 1701, started to decrease and a gram positive tetrad coccus became predominant. When the feeding pattern was returned to continuous feeding, Type 1701 re-appeared. Type 1701 has lower glycogen reservation capacity than the tetrad coccus. Therefore, the former cannot dominate over the latter in intermittently fed reactors.


1995 ◽  
Vol 32 (9-10) ◽  
pp. 75-84 ◽  
Author(s):  
A. D. Andreadakis ◽  
G. H. Kristensen ◽  
A. Papadopoulos ◽  
C. Oikonomopoulos

The wastewater from the city of Thessaloniki is discharged without treatment to the nearby inner part of the Thessaloniki Gulf. The existing, since 1989, treatment plant offers only primary treatment and did not operate since the expected effluent quality is not suitable for safe disposal to the available recipients. Upgrading of the plant for advanced biological treatment, including seasonal nitrogen removal, is due from 1995. In the mean time, after minor modifications completed in February 1992, the existing plant was put into operation as a two-stage chemical-biological treatment plant for 40 000 m3 d−1, which corresponds to about 35% of the total sewage flow. The operational results obtained during the two years operation period are presented and evaluated. All sewage and sludge treatment units of the plant perform better than expected, with the exception of the poor sludge settling characteristics, due to severe and persistent bulking caused by excessive growth of filamentous microorganisms, particularly M. Parvicella. Effective control of the bulking problem could lead to more cost-effective operation and increased influent flows.


2010 ◽  
Vol 150 ◽  
pp. 44-44 ◽  
Author(s):  
Kimchhayarasy. Phuong ◽  
Kazuo. Kakii ◽  
Toshiyuki. Nikata

Sign in / Sign up

Export Citation Format

Share Document