Impact of air distribution on indoor formaldehyde abatement with/without passive removal material: A CFD modeling

2022 ◽  
pp. 108792
Author(s):  
Mojtaba Malayeri ◽  
Mitra Bahri ◽  
Fariborz Haghighat ◽  
Apoorv Shah
Author(s):  
Hamza Begdouri ◽  
Luis Rosario ◽  
Muhammad M. Rahman

This study considers airflow simulations to evaluate the impact of different window air-conditioner locations on the thermal comfort in an office rooms (OR). This paper compares the air distribution for an office room by using computational fluid dynamics (CFD) modeling. The air distribution was modeled for a typical office room window air conditioning unit, air supply from a high pressure on the top and the low pressure exhaust on the bottom considering the existing manufacturing ratios for surface areas. Calculations were done for steady-state conditions including an occupant and a light source. The discharge angle for the supply grill of the AC unit was varied from 20 to 40 degrees. The position of the air conditioner was also varied and studied at 60%, 75% and 90% of the total height of the room. In addition the location of the occupant within the office room was varied. Predictions of the air movement, room temperature, room relative humidity, comfort level, and distribution of contaminants within the office room are shown. Analysis of these simulations is discussed. The positions of the air-conditioner unit, the inlet angle and the occupant position in the office room have shown to have important impacts on air quality and thermal comfort. Results are in good agreement with available experimental data.


Author(s):  
Ali Fazeli ◽  
Mohsen Behnam

Producing hydrogen from natural gas for a mini scale fuel cell is a new challenge for researchers. Therefore, modeling of hydrogen production microreactors should be helpful for designing and developing new microreactors. Experimental sensing of velocity, concentration, temperature and reaction rates in numerous points of the microreactor is impracticable. A microreactor in special geometry was considered for hydrogen production and a CFD model was developed in order to incorporate the mechanism of autothermal reforming. This mechanism includes three main reactions and Langmuir-Hinshelwood type kinetic rates. A three dimensional reformer model was developed to simulate the reactive laminar flow model of this microreactor. Effects of styles of feed entrance, air to fuel ratio and adding water to methane were studied. This model shows that there are hot spots near the entrance of the microreactor where the total oxidation of methane occurs and air distribution along the microreactor is a good solution for hot spot problems. The model shows that air distribution is good for fuel cell application because of high hydrogen production and low CO content in the outlet.


Solar Energy ◽  
2006 ◽  
Author(s):  
Kybum Jeong ◽  
Moncef Krarti ◽  
Zhiqiang Zhai

The partition air distribution systems evaluated in this study allow occupants to control the system mode (on/off) and the supply air velocity and direction with similar flexibility as occupants in automobiles. To find optimal specifications for the partition air distribution systems that are able to achieve comfortable micro-environment, a CFD modeling tool was used to simulate the airflow and thermal performance of the partition air distribution systems in a typical office space. By analyzing the distribution characteristics of indoor air temperature, air velocity and thermal comfort index, the study assessed the performance of the partition air distribution systems with different operating parameters. The simulation results were analyzed and evaluated to assess both occupant’s thermal comfort and system energy consumption. The study shows that space cooling energy can be reduced while maintaining acceptable indoor thermal comfort level using a partition air distribution system with a higher supply air temperature.


Author(s):  
Greg Epelbaum

American Ref-Fuel Company (ARC) spends millions of dollars each year on corrosion related costs in the boilers. The corrosion is caused by chloride salts in the slag that deposit on the boiler tubes, coupled with the high temperatures of flue gas going through the boiler. Corrosion rates are known to be very sensitive to the flue gas temperature and velocity, surface temperature and heat flux through the slag, oxygen in flue gas distribution, etc. These parameters are primarily determined by the firing rate of the boiler, and they are also affected by combustion control and air distribution in the boiler. Some design parameters, such as surface area of refractory, tile, and inconel overlay, also affect the flue gas temperature throughout the boiler, and thereby impact corrosion.


TAPPI Journal ◽  
2015 ◽  
Vol 14 (1) ◽  
pp. 51-60
Author(s):  
HONGHI TRAN ◽  
DANNY TANDRA

Sootblowing technology used in recovery boilers originated from that used in coal-fired boilers. It started with manual cleaning with hand lancing and hand blowing, and evolved slowly into online sootblowing using retractable sootblowers. Since 1991, intensive research and development has focused on sootblowing jet fundamentals and deposit removal in recovery boilers. The results have provided much insight into sootblower jet hydrodynamics, how a sootblower jet interacts with tubes and deposits, and factors influencing its deposit removal efficiency, and have led to two important innovations: fully-expanded sootblower nozzles that are used in virtually all recovery boilers today, and the low pressure sootblowing technology that has been implemented in several new recovery boilers. The availability of powerful computing systems, superfast microprocessors and data acquisition systems, and versatile computational fluid dynamics (CFD) modeling capability in the past two decades has also contributed greatly to the advancement of sootblowing technology. High quality infrared inspection cameras have enabled mills to inspect the deposit buildup conditions in the boiler during operation, and helped identify problems with sootblower lance swinging and superheater platens and boiler bank tube vibrations. As the recovery boiler firing capacity and steam parameters have increased markedly in recent years, sootblowers have become larger and longer, and this can present a challenge in terms of both sootblower design and operation.


Author(s):  
B. S. Soroka

The article considers the role and place of water and water vapor in combustion processes with the purpose of reduction the effluents of nitrogen oxides and carbon oxide. We have carried out the complex of theoretical and computational researches on reduction of harmful nitrogen and carbon oxides by gas fuel combustion in dependence on humidity of atmospheric air by two approaches: CFD modeling with attraction of DRM 19 chemical kinetics mechanism of combustion for 19 components along with Bowman’s mechanism used as “postprocessor” to determine the [NO] concentration; different thermodynamic models of predicting the nitrogen oxides NO formation. The numerical simulation of the transport processes for momentum, mass and heat being solved simultaneously in the united equations’ system with the chemical kinetics equations in frame of GRI methane combustion mechanism and NO formation calculated afterwards as “postprocessor” allow calculating the absolute actual [CO] and [NO] concentrations in dependence on combustion operative conditions and on design of furnace facilities. Prediction in frame of thermodynamic equilibrium state for combustion products ensures only evaluation of the relative value of [NO] concentration by wet combustion the gas with humid air regarding that in case of dry air – oxidant. We have developed the methodology and have revealed the results of numerical simulation of impact of the relative humidity of atmospheric air on harmful gases formation. Range of relative air humidity under calculations of atmospheric air under impact on [NO] and [CO] concentrations at the furnace chamber exit makes φ = 0 – 100%. The results of CFD modeling have been verified both by author’s experimental data and due comparing with the trends stated in world literature. We have carried out the complex of the experimental investigations regarding atmospheric air humidification impact on flame structure and environmental characteristics at natural gas combustion with premixed flame formation in open air. The article also proposes the methodology for evaluation of the nitrogen oxides formation in dependence on moisture content of burning mixture. The results of measurements have been used for verification the calculation data. Coincidence of relative change the NO (NOx) yield due humidification the combustion air revealed by means of CFD prediction has confirmed the qualitative and the quantitative correspondence of physical and chemical kinetics mechanisms and the CFD modeling procedures with the processes to be studied. A sharp, more than an order of reduction in NO emissions and simultaneously approximately a two-fold decrease in the CO concentration during combustion of the methane-air mixture under conditions of humidification of the combustion air to a saturation state at a temperature of 325 K.


2019 ◽  
Vol 46 (2) ◽  
pp. 101-112
Author(s):  
Nidhal Hnaien ◽  
Saloua Marzouk ◽  
Lioua Kolsi ◽  
Hatem Gasmi ◽  
Habib Ben Aissia ◽  
...  
Keyword(s):  
Wall Jet ◽  

Sign in / Sign up

Export Citation Format

Share Document