CFD Modeling of Film Cooling Flow with Inclined Jets

Author(s):  
Majid Almas ◽  
2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Jianlong Chang ◽  
Xinlei Duan ◽  
Yang Du ◽  
Baoquan Guo ◽  
Yutian Pan

AbstractBy combining the synthetic jet and film cooling, the incident cooling flow is specially treated to find a better film cooling method. Numerical simulations of the synthetic coolant ejected are carried out for analyzing the cooling performance in detail, under different blowing ratios, hole patterns, Strouhal numbers, and various orders of incidence for the two rows of holes. By comparing the flow structures and the cooling effect corresponding to the synthetic coolant and the steady coolant fields, it is found that within the scope of the investigations, the best cooling effect can be obtained under the incident conditions of an elliptical hole with the aspect ratio of 0.618, the blow molding ratio of 2.5, and the Strouhal number St = 0.22. Due to the strong controllability of the synthetic coolant, the synthetic coolant can be controlled through adjusting the frequency of blowing and suction, so as to change the interaction between vortex structures for improving film cooling effect in turn. As a result, the synthetic coolant ejection is more advisable in certain conditions to achieve better outcomes.


Author(s):  
S. Friedrichs ◽  
H. P. Hodson ◽  
W. N. Dawes

The endwall film-cooling cooling configuration investigated by Friedrichs et al. (1996, 1997) had in principle sufficient cooling flow for the endwall, but in practice, the redistribution of this coolant by secondary flows left large endwall areas uncooled. This paper describes the attempt to improve upon this datum cooling configuration by redistributing the available coolant to provide a better coolant coverage on the endwall surface, whilst keeping the associated aerodynamic losses small. The design of the new, improved cooling configuration was based on the understanding of endwall film-cooling described by Friedrichs et al. (1996, 1997). Computational fluid dynamics were used to predict the basic flow and pressure field without coolant ejection. Using this as a basis, the above described understanding was used to place cooling holes so that they would provide the necessary cooling coverage at minimal aerodynamic penalty. The simple analytical modelling developed in Friedrichs et al. (1997) was then used to check that the coolant consumption and the increase in aerodynamic loss lay within the limits of the design goal. The improved cooling configuration was tested experimentally in a large scale, low speed linear cascade. An analysis of the results shows that the redesign of the cooling configuration has been successful in achieving an improved coolant coverage with lower aerodynamic losses, whilst using the same amount of coolant as in the datum cooling configuration. The improved cooling configuration has reconfirmed conclusions from Friedrichs et al. (1996, 1997); firstly, coolant ejection downstream of the three-dimensional separation lines on the endwall does not change the secondary flow structures; secondly, placement of holes in regions of high static pressure helps reduce the aerodynamic penalties of platform coolant ejection; finally, taking account of secondary flow can improve the design of endwall film-cooling configurations.


Author(s):  
Siavash Khajehhasani ◽  
Bassam Jubran

A numerical study on the effects of sister holes locations on film cooling performance is presented. This includes the change of the location of the individual discrete sister holes in the streamwise and spanwise directions, where each one of these directions includes 9 different locations, The simulations are performed using three-dimensional Reynolds-Averaged Navier Stokes analysis with the realizable k–ε model combined with the standard wall function. The variation of the sister holes in the streamwise direction provides similar film cooling performance as the base case for both blowing ratios of 0.5 and 1. On the other hand, the spanwise variation of the sister holes’ location has a more prominent effect on the effectiveness. In some cases, as a result of the anti-vortices generated from the sister holes and the repositioning of the sister holes in the spanwise direction, the jet lift-off effect notably decreases and more volume of coolant is distributed in the spanwise direction.


1997 ◽  
Vol 119 (3) ◽  
pp. 568-573 ◽  
Author(s):  
P. M. Ligrani ◽  
R. Gong ◽  
J. M. Cuthrell

Experimental results are presented that describe the effects of bulk flow pulsations on film cooling from a single row of simple angle film cooling holes. The pulsations are in the form of sinusoidal variations of static pressure and streamwise velocity. Such pulsations are important in turbine studies because: (i) Static pressure pulsations result in significant periodic variations of film cooling flow rates, coverage, and trajectories, and (ii) static pressure pulsations occur near blade surfaces in operating engines from potential flow interactions between moving blade rows and from families of passing shock waves. Distributions of ensemble-averaged and time-averaged Reynolds stress tensor components are investigated just downstream of the holes along with distributions of all three mean velocity components. Important changes are evident in all measured quantities. In particular, maximum Reynolds shear stresses −2u′υ′/u∞2 are lower in regions containing the largest film concentrations because the strong shear layer produced by the injectant is more three dimensional, larger in extent, and oscillates its position from the wall with time.


Author(s):  
Todd A. Oliver ◽  
Joshua B. Anderson ◽  
David G. Bogard ◽  
Robert D. Moser ◽  
Gregory Laskowski

Results of a recent joint experimental and computational investigation of the flow through a plenum-fed 7-7-7 shaped film cooling hole are presented. In particular, we compare the measured adiabatic effectiveness and mean temperature against implicit large eddy simulation (iLES) for blowing ratio approximately 2, density ratio 1.6, and Reynolds number 6000. The results overall show reasonable agreement between the iLES and the experimental results for the adiabatic effectiveness and gross features of the mean temperature field. Notable discrepancies include the centerline adiabatic effectiveness near the hole, where the iLES under-predicts the measurements by Δη ≈ 0.05, and the near-wall temperature, where the simulation results show features not present in the measurements. After showing this comparison, the iLES results are used to examine features that were not measured in the experiments, including the in-hole flow and the dominant fluxes in the mean internal energy equation downstream of the hole. Key findings include that the flow near the entrance to the hole is highly turbulent and that there is a large region of backflow near the exit of the hole. Further, the well-known counter-rotating vortex pair downstream of the hole is observed. Finally, the typical gradient diffusion hypothesis for the Reynolds heat flux is evaluated and found to be incorrect.


Author(s):  
Rui Hou ◽  
Fengbo Wen ◽  
Yuxi Luo ◽  
Xiaolei Tang ◽  
Songtao Wang

Author(s):  
Steven W. Burd ◽  
Terrence W. Simon

Experimental hot-wire anemometry and thermocouple measurements are taken to document the sensitivity which film cooling performance has to the hole length and the geometry of the plenum which supplies cooling flow to the holes. This sensitivity is described in terms of the effects these geometric features have on hole-exit velocity and turbulence intensity distributions and on adiabatic effectiveness values on the surface downstream. These measurements were taken under high freestream turbulence intensity (12%) conditions, representative of operating gas turbine engines. Coolant is supplied to the film cooling holes by means of (1) an unrestricted plenum, (2) a plenum which restricts the flow approaching the holes, forcing it to flow co-current with the freestream, and (3) a plenum which forces the flow to approach the holes counter-current with the freestream. Short-hole (L/D = 2.3) and long-hole (L/D = 7.0) comparisons are made. The geometry has a single row of film cooling holes with 35°-inclined streamwise injection. The film cooling flow is supplied at the same temperature as that of the freestream for hole-exit measurements and 10°C above the freestream temperature for adiabatic effectiveness measurements, yielding density ratios in the range 0.96–1.0. Two coolant-to-freestream velocity ratios, 0.5 and 1.0, are investigated. The results document the effects of (1) supply plenum geometry, (2) velocity ratio, and (3) hole L/D.


Author(s):  
Felipe A. C. Viana ◽  
Jack Madelone ◽  
Niranjan Pai ◽  
Genghis Khan ◽  
Sanghum Baik

To achieve high efficiency, modern gas turbines operate at temperatures that exceed melting points of metal alloys used in turbine hot gas path parts. Parts exposed to hot gas are actively cooled with a portion of the compressor discharge air (e.g., through film cooling) to keep the metal temperature at levels needed to meet durability requirements. However, to preserve efficiency, it is important to optimize the cooling system to use the least amount of cooling flow. In this study, film cooling optimization is achieved by varying cooling hole diameters, hole to hole spacing, and film row placements so that the specified targets for maximum metal temperature are met while preserving (or saving) cooling flow. The computational cost of the high-fidelity physics models, the large number of design variables, the large number and nonlinearity of responses impose severe challenges to numerical optimization. Design of experiments and cheap-to-evaluate approximations (radial basis functions) are used to alleviate the computational burden. Then, the goal attainment method is used for optimizing of film cooling configuration. The results for a turbine blade design show significant improvements in temperature distribution while maintaining/reducing the amount of used cooling flow.


Author(s):  
Kam S. Chana ◽  
Mary A. Hilditch ◽  
James Anderson

Cooling is required to enable the turbine components to survive and have acceptable life in the very high gas temperatures occurring in modern engines. The cooling air is bled from the compression system, with typically about 15% of the core flow being diverted in military engines and about 20% in civil turbofans. Cooling benefits engine specific thrust and efficiency by allowing higher cycle temperatures to be employed, but the bleed air imposes cycle penalties and also reduces the aerodynamic efficiency of the turbine blading, typically by 2–4%. Cooling research aims to develop and validate improved design methodologies that give maximum cooling effectiveness for minimum cooling flow. This paper documents external cooling research undertaken in the Isentropic Light Piston Facility at QinetiQ as part of a European collaborative programme on turbine aerodynamics and heat transfer. In Phase I, neither the ngv nor the rotor was cooled; cooling was added to the ngv only for Phase II, and to the rotor and ngv in Phase III. Coolant blowing rates and density ratios were also varied in the experiments. This paper describes the ILPF and summarises the results of this systematic programme, paying particular attention to the variation in aerofoil heat transfer with changing coolant conditions, and the effects coolant ejection has on the aerofoil’s aerodynamic performance.