Feasibility of in situ enriching anammox bacteria in a sequencing batch biofilm reactor (SBBR) for enhancing nitrogen removal of real domestic wastewater

2018 ◽  
Vol 352 ◽  
pp. 847-854 ◽  
Author(s):  
Jianhua Zhang ◽  
Liang Zhang ◽  
Yuanyuan Miao ◽  
Yawen Sun ◽  
Xiyao Li ◽  
...  
Processes ◽  
2022 ◽  
Vol 10 (1) ◽  
pp. 109
Author(s):  
Yu Huang ◽  
Yongzhen Peng ◽  
Donghui Huang ◽  
Jiarui Fan ◽  
Rui Du

A partial-denitrification coupling with anaerobic ammonium oxidation (anammox) process (PD/A) in a continuous-flow anoxic/oxic (A/O) biofilm reactor was developed to treat carbon-limited domestic wastewater (ammonia (NH4+-N) of 55 mg/L and chemical oxygen demand (COD) of 148 mg/L in average) for about 200 days operation. Satisfactory NH4+-N oxidation efficiency above 95% was achieved with rapid biofilm formation in the aerobic zone. Notably, nitrite (NO2−-N) accumulation was observed in the anoxic zone, mainly due to the insufficient electron donor for complete nitrate (NO3−-N) reduction. The nitrate-to-nitrite transformation ratio (NTR) achieved was as high as 64.4%. After the inoculation of anammox-enriched sludge to anoxic zones, total nitrogen (TN) removal was significantly improved from 37.3% to 78.0%. Anammox bacteria were effectively retained in anoxic biofilm utilizing NO2−-N produced via the PD approach and NH4+-N in domestic wastewater, with the relative abundance of 5.83% for stable operation. Anammox pathway contributed to TN removal by a high level of 38%. Overall, this study provided a promising method for mainstream nitrogen removal with low energy consumption and organic carbon demand.


2020 ◽  
Vol 81 (5) ◽  
pp. 1071-1079
Author(s):  
Caimeng Wang ◽  
Lirong Lei ◽  
Fangrui Cai ◽  
Youming Li

Abstract In this study, the completely autotrophic nitrogen removal over nitrite (CANON) process was initiated in a sequencing batch biofilm reactor (SBBR). Then the reactor was operated under different IC/N ratios. The total inorganic nitrogen removal efficiency (TINRE) at IC/N ratios of 0.75, 1.0, 1.25, 1.5 and 2.0 were 37.0 ± 11.0%, 58.9 ± 10.2%, 73.9 ± 3.2%, 73.6 ± 1.8% and 72.6 ± 2.0%, respectively. The suitable range of IC/N ratio in this research is 1.25–2.0. The poor nitrogen removal performance at IC/N ratio of 0.75 was due to the lack of growth substrate for AnAOB and low pH simultaneously; at IC/N ratio of 1.0 this was because the substrate concentration was insufficient for fully recovering the AnAOB activities. Microbial analysis indicated that Nitrosomonas, Nitrospira and Candidatus Brocadia were the main ammonium oxidation bacteria (AOB), nitrite oxidation bacteria (NOB) and anammox bacteria (AnAOB), respectively. In addition, at IC ratios of 1.25 or higher, denitrification was promoted with the rise of IC/N ratio, which might be because the change of IC concentrations caused cell lysis of microorganisms and provided organic matter for denitrification.


2014 ◽  
Vol 955-959 ◽  
pp. 2318-2321
Author(s):  
Dong Yuan

The objective of this work was to evaluate the performances of A lab-scale innovative sequencing batch biofilm reactor (SBBR) to treat domestic wastewater,in which a acryl cylinder (height 200 mm, diameter 70 mm) was equipped and many fiber threads were attached to the surface of the cylinder as the bacteria carrier. No time and volume for settling was required in this system. After one year’s operation, each parameter achieved the wastewater discharged criterion in 2 cycles (4 h). It was found that COD removal efficiency was up to 90% in 3 h, and ammonium nitrogen concentration approached the least value; total nitrogen removal efficiency reached 55%-71%. In this SBBR system simultaneous nitrification and denitrification was completed at the end of 2 cycles.


2010 ◽  
Vol 62 (11) ◽  
pp. 2599-2606 ◽  
Author(s):  
Hong Xiao ◽  
Ping Yang ◽  
Hong Peng ◽  
Yanzong Zhang ◽  
Shihuai Deng ◽  
...  

A study was conducted regarding the biological nitrogen removal from the livestock and poultry breeding wastewater (LPBWs) using a novel sequencing batch biofilm reactor (SBBR). Nitrogen removal process was studied under three aeration strategies/modes, referred to as MODE 1, 2, and 3. The results showed that MODE 2 (one operation period: instant fill of LPBWs, 3.0 h aeration, 1.5 h non-aeration, 1.5 h aeration, 1.0 h non-aeration and rapid drain of treated LPBWs) performed the best in nitrogen removal. Under MODE 2, the removal efficiencies were as high as 96.1 and 92.1% for NH3-N and TN, respectively. Simultaneous nitrification and denitrification (SND), as well as shortcut nitrification and denitrification are likely to be the two main mechanisms for the nitrogen removal in this study. Nitrifying bateria were not inhibited by heterotrophic bacteria with C/N ratios ranging from 18.1 to 21.4 and DO concentration of 2.0 mg/l. Alternation between aeration and non-aeration played an important role in NO2−-N accumulation.


2016 ◽  
Vol 74 (11) ◽  
pp. 2666-2674 ◽  
Author(s):  
A. Sarti ◽  
A. W. Lamon ◽  
A. Ono ◽  
E. Foresti

This study proposes a new approach to selecting a biofilm carrier for immobilization using dissolved oxygen (DO) microsensors to measure the thickness of aerobic and anaerobic layers in biofilm. The biofilm carriers tested were polyurethane foam, mineral coal (MC), basaltic gravel, and low-density polyethylene. Development of layers in the biofilm carrier surface was evaluated using a flow cell device, and DO profiles were conducted to determine the size of the layers (aerobic and anaerobic). MC was the biofilm carrier selected due to allowing the development of larger aerobic and anaerobic layers in the biofilm (896 and 1,058 μm, respectively). This ability is supposed to improve simultaneous nitrogen removal by nitrification and denitrification biological processes. Thus, as a biofilm carrier, MC was used in a fixed-bed sequencing batch biofilm reactor (FB-SBBR) for treatment of wastewater with a high ammonia concentration (100–400 mgNH4+-N L−1). The FB-SBBR (15.0 L) was filled with matrices of the carrier and operated under alternating aeration and non-aeration periods of 6 h each. At a mean nitrogen loading rate of 0.55 ± 0.10 kgNH4+-N m−3 d−1, the reactor attained a mean nitrification efficiency of 95 ± 9% with nitrite as the main product (aerobic period). Mean denitrification efficiency during the anoxic period was 72 ± 13%.


Sign in / Sign up

Export Citation Format

Share Document