Nitrogen removal from livestock and poultry breeding wastewaters using a novel sequencing batch biofilm reactor

2010 ◽  
Vol 62 (11) ◽  
pp. 2599-2606 ◽  
Author(s):  
Hong Xiao ◽  
Ping Yang ◽  
Hong Peng ◽  
Yanzong Zhang ◽  
Shihuai Deng ◽  
...  

A study was conducted regarding the biological nitrogen removal from the livestock and poultry breeding wastewater (LPBWs) using a novel sequencing batch biofilm reactor (SBBR). Nitrogen removal process was studied under three aeration strategies/modes, referred to as MODE 1, 2, and 3. The results showed that MODE 2 (one operation period: instant fill of LPBWs, 3.0 h aeration, 1.5 h non-aeration, 1.5 h aeration, 1.0 h non-aeration and rapid drain of treated LPBWs) performed the best in nitrogen removal. Under MODE 2, the removal efficiencies were as high as 96.1 and 92.1% for NH3-N and TN, respectively. Simultaneous nitrification and denitrification (SND), as well as shortcut nitrification and denitrification are likely to be the two main mechanisms for the nitrogen removal in this study. Nitrifying bateria were not inhibited by heterotrophic bacteria with C/N ratios ranging from 18.1 to 21.4 and DO concentration of 2.0 mg/l. Alternation between aeration and non-aeration played an important role in NO2−-N accumulation.

Author(s):  
Mehdi Hajsardar ◽  
Seyed Mehdi Borghei ◽  
Amir Hessam Hassani ◽  
Afshin Takdastan

Abstract A series of reactors including a sequencing batch reactor (SBR) and a sequencing batch biofilm reactor (SBBR) were used for nitrogen removal. The aim of this study was simultaneous removal of NH4+-N and NOx–-N from synthetic wastewater. In the novel proposed method, the effluent from SBR was sequentially introduced into SBBR, which contained 0.030 m3 biofilm carriers, so the system operated under a paired sequence of aerobic-anoxic conditions. The effects of different carbon sources and aeration conditions were investigated. A low dissolved oxygen (DO) level in the biofilm depth of the fixed-bed process (SBBR) simulated the anoxic phase conditions. Accordingly, a portion of NH4+-N that was not converted to NO3–-N by the SBR process was converted to NO3–-N in the outer layer of the biofilm in the SBBR process. Further, simultaneous nitrification and denitrification (SND) was achieved in the SBBR where NO2–-N was converted to N2 directly, before NO3–-N conversion (partial nitrification). The level of mixed liquid suspended solids (MLSS) was 2740 mg/l at the start of the experiments. The required carbon source (C: N ratio of 4) was provided by adding an internal carbon source (through step feeding) or ethanol. Firstly, as part of the system (SBR and SBBR), SBR operated at a DO level of 1 mg/l while SBBR operated at a DO concentration of 0.3 mg/l during Run-1. During Run-2, the system operated at the low DO concentration of 0.3 mg/l. When the source of carbon was ethanol, the nitrogen removal rate (RN) was higher than the operation with an internal carbon source. When the reactors were operated at the same DO concentration of 0.3 mg/l, 99.1 % of the ammonium was removed. The NO3–-N produced during the aerobic SBR operation of the novel method was removed in SBBR reactor by 8.3 %. The concentrations of NO3--N and NO2–-N in the SBBR effluent were reduced to 2.5 and 5.5 mg/l, respectively. Also, the total nitrogen (TN) removal efficiency was 97.5 % by adding ethanol at the DO level of 0.3 mg/l. When C:N adjustment was carried out SND efficiency at C:N ratio of 6.5 reached to 99 %. The increasing nitrogen loading rate (NLR) to 0.554 kg N/m3 d decreased SND efficiency to 80.7 %.


2020 ◽  
Vol 218 ◽  
pp. 03033
Author(s):  
Yafeng Li ◽  
Jianbo Wu ◽  
Yuemeng Bai ◽  
Ning Feng

In order to improve the efficiency of biological nitrogen removal, the experiment used the luffa cylindrical sponge carrier sequencing batch biofilm reactor to treat domestic sewage, and it studied the temperature on the removal effect of TN in the sewage in the reactor and the changes of various types of nitrogen. The results showed that the TN treatment rate of the luffa cylindrical sponge carrier SBBR reached the peak at 30 °C, the removal rate was 82.25%, indicating that the luffa cylindrical sponge carrier SBBR is very suitable for the removal of nitrogen from domestic sewage.


Processes ◽  
2022 ◽  
Vol 10 (1) ◽  
pp. 109
Author(s):  
Yu Huang ◽  
Yongzhen Peng ◽  
Donghui Huang ◽  
Jiarui Fan ◽  
Rui Du

A partial-denitrification coupling with anaerobic ammonium oxidation (anammox) process (PD/A) in a continuous-flow anoxic/oxic (A/O) biofilm reactor was developed to treat carbon-limited domestic wastewater (ammonia (NH4+-N) of 55 mg/L and chemical oxygen demand (COD) of 148 mg/L in average) for about 200 days operation. Satisfactory NH4+-N oxidation efficiency above 95% was achieved with rapid biofilm formation in the aerobic zone. Notably, nitrite (NO2−-N) accumulation was observed in the anoxic zone, mainly due to the insufficient electron donor for complete nitrate (NO3−-N) reduction. The nitrate-to-nitrite transformation ratio (NTR) achieved was as high as 64.4%. After the inoculation of anammox-enriched sludge to anoxic zones, total nitrogen (TN) removal was significantly improved from 37.3% to 78.0%. Anammox bacteria were effectively retained in anoxic biofilm utilizing NO2−-N produced via the PD approach and NH4+-N in domestic wastewater, with the relative abundance of 5.83% for stable operation. Anammox pathway contributed to TN removal by a high level of 38%. Overall, this study provided a promising method for mainstream nitrogen removal with low energy consumption and organic carbon demand.


2016 ◽  
Vol 74 (11) ◽  
pp. 2666-2674 ◽  
Author(s):  
A. Sarti ◽  
A. W. Lamon ◽  
A. Ono ◽  
E. Foresti

This study proposes a new approach to selecting a biofilm carrier for immobilization using dissolved oxygen (DO) microsensors to measure the thickness of aerobic and anaerobic layers in biofilm. The biofilm carriers tested were polyurethane foam, mineral coal (MC), basaltic gravel, and low-density polyethylene. Development of layers in the biofilm carrier surface was evaluated using a flow cell device, and DO profiles were conducted to determine the size of the layers (aerobic and anaerobic). MC was the biofilm carrier selected due to allowing the development of larger aerobic and anaerobic layers in the biofilm (896 and 1,058 μm, respectively). This ability is supposed to improve simultaneous nitrogen removal by nitrification and denitrification biological processes. Thus, as a biofilm carrier, MC was used in a fixed-bed sequencing batch biofilm reactor (FB-SBBR) for treatment of wastewater with a high ammonia concentration (100–400 mgNH4+-N L−1). The FB-SBBR (15.0 L) was filled with matrices of the carrier and operated under alternating aeration and non-aeration periods of 6 h each. At a mean nitrogen loading rate of 0.55 ± 0.10 kgNH4+-N m−3 d−1, the reactor attained a mean nitrification efficiency of 95 ± 9% with nitrite as the main product (aerobic period). Mean denitrification efficiency during the anoxic period was 72 ± 13%.


Sign in / Sign up

Export Citation Format

Share Document