Hemoglobin (Hb) immobilized on amino-modified magnetic nanoparticles for the catalytic removal of bisphenol A

Chemosphere ◽  
2011 ◽  
Vol 83 (3) ◽  
pp. 255-264 ◽  
Author(s):  
Tiantian Tang ◽  
Hai Fan ◽  
Shiyun Ai ◽  
Ruixia Han ◽  
Yanyan Qiu
NANO ◽  
2019 ◽  
Vol 14 (05) ◽  
pp. 1950065
Author(s):  
Yongsheng Jia ◽  
Enze Li ◽  
Zhiping Du ◽  
Jianfeng Li ◽  
Fangqin Cheng

Bisphenol A is not only one of the frequent contaminants of industrial wastewater, but also one of the main ingredients in polycarbonate and epoxy resins. This study synthesizes a pH-triggered Fe3O4@mSiO2@DPDES adsorbent for recycling Bisphenol A through adsorption–desorption process. Due to the strong [Formula: see text]–[Formula: see text] interaction between the phenyl groups in diphenyldiethoxysilane modified magnetic nanoparticles (MNPs) and Bisphenol A, absorbance reached 120.17[Formula: see text]mg/g at pH 7, allowing the bisphenol A adsorbed to Fe3O4@mSiO2@DPDES to be trivially separated from aqueous solutions with a magnet. Desorption of the adsorbed bisphenol A in aqueous solution occurred at pH 2, allowing an impressive 95% recovery rate. The durability of the Fe3O4@mSiO2@DPDES adsorbent was tested by repeated separation of bisphenol A from an aqueous solution, with the recovery efficiency remaining greater than 85% after five cycles.


Langmuir ◽  
2011 ◽  
Vol 27 (6) ◽  
pp. 3106-3112 ◽  
Author(s):  
Fei Xu ◽  
James H. Geiger ◽  
Gregory L. Baker ◽  
Merlin L. Bruening

2021 ◽  
Vol 22 (12) ◽  
pp. 6571
Author(s):  
Yu-Chen Liu ◽  
Katragunta Kumar ◽  
Cheng-Hsiu Wu ◽  
Kai-Chih Chang ◽  
Cheng-Kang Chiang ◽  
...  

A nucleic acid aptamer that specifically recognizes methicillin-resistant Staphylococcus aureus (MRSA) has been immobilized on magnetic nanoparticles to capture the target bacteria prior to mass spectrometry analysis. After the MRSA species were captured, they were further eluted from the nanoparticles and identified using matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS). The combination of aptamer-based capture/enrichment and MS analysis of microorganisms took advantage of the selectivity of both techniques and should enhance the accuracy of MRSA identification. The capture and elution efficiencies for MRSA were optimized by examining factors such as incubation time, temperature, and elution solvents. The aptamer-modified magnetic nanoparticles showed a capture rate of more than 90% under the optimized condition, whereas the capture rates were less than 11% for non-target bacteria. The as-prepared nanoparticles exhibited only a 5% decrease in the capture rate and a 9% decrease in the elution rate after 10 successive cycles of utilization. Most importantly, the aptamer-modified nanoparticles revealed an excellent selectivity towards MRSA in bacterial mixtures. The capture of MRSA at a concentration of 102 CFU/mL remained at a good percentage of 82% even when the other two species were at 104 times higher concentration (106 CFU/mL). Further, the eluted MRSA bacteria were successfully identified using MALDI mass spectrometry.


Sign in / Sign up

Export Citation Format

Share Document