scholarly journals Novel cationic surfactants from fatty acids and their corrosion inhibition efficiency for carbon steel pipelines in 1M HCl

2011 ◽  
Vol 20 (2) ◽  
pp. 47-57 ◽  
Author(s):  
A.M. Al-Sabagh ◽  
N.Gh. Kandil ◽  
O. Ramadan ◽  
N.M. Amer ◽  
R. Mansour ◽  
...  
Materials ◽  
2020 ◽  
Vol 13 (19) ◽  
pp. 4245
Author(s):  
Gaetano Palumbo ◽  
Kamila Kollbek ◽  
Roma Wirecka ◽  
Andrzej Bernasik ◽  
Marcin Górny

The effect of CO2 partial pressure on the corrosion inhibition efficiency of gum arabic (GA) on the N80 carbon steel pipeline in a CO2-water saline environment was studied by using gravimetric and electrochemical measurements at different CO2 partial pressures (e.g., PCO2 = 1, 20 and 40 bar) and temperatures (e.g., 25 and 60 °C). The results showed that the inhibitor efficiency increased with an increase in inhibitor concentration and CO2 partial pressure. The corrosion inhibition efficiency was found to be 84.53% and 75.41% after 24 and 168 h of immersion at PCO2 = 40 bar, respectively. The surface was further evaluated by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), grazing incidence X-ray diffraction (GIXRD), and X-ray photoelectron spectroscopy (XPS) measurements. The SEM-EDS and GIXRD measurements reveal that the surface of the metal was found to be strongly affected by the presence of the inhibitor and CO2 partial pressure. In the presence of GA, the protective layer on the metal surface becomes more compact with increasing the CO2 partial pressure. The XPS measurements provided direct evidence of the adsorption of GA molecules on the carbon steel surface and corroborated the gravimetric results.


2018 ◽  
Vol 34 (5) ◽  
pp. 2471-2476 ◽  
Author(s):  
Hamida Edan Salman ◽  
Asim A. Balakit ◽  
Ali Ahmed Abdulridha

A new aromatic Schiff base with azo linkage (AS) has been synthesized and characterized by FT-IR, 1H NMR and 13C NMR spectroscopic techniques. The new compound (AS) has been evaluated as carbon steel corrosion inhibitor at different concentrations (0.005, 0.01, 0.02, 0.04 and 0.08 mM) and different temperatures (303 – 333 K). The corrosion inhibition efficiency was studied by potentiodynamic polarization and weight loss measurements. The effects of concentration and temperature on the inhibition efficiency were studied by potentiodynamic polarization studies, the results showed that increasing concentration of AS increases the inhibition efficiency while increasing the temperature decreases it, the highest corrosion inhibition efficiency, 93.9% was recorded with 0.08 mM of AS at 313 K in 1 M H2SO4. Weight loss measurements showed that the inhibition efficiency reached 97.1% in the presence of AS (0.08 mM) at 313 K. The adsorption process was found to obey Langmuir isotherm, and the adsorption thermodynamic parameters were studied. Scanning electron microscope (SEM) was used to confirm the results.


2012 ◽  
Vol 21 (2) ◽  
pp. 89-100 ◽  
Author(s):  
A.M. Al-Sabagh ◽  
H.M. Abd-El-Bary ◽  
R.A. El-Ghazawy ◽  
M.R. Mishrif ◽  
B.M. Hussein

RSC Advances ◽  
2017 ◽  
Vol 7 (58) ◽  
pp. 36688-36696 ◽  
Author(s):  
Sami Ben Aoun

The corrosion inhibition efficiency of 1-hexylpyridinium bromide for carbon steel in molar hydrochloric acid has been investigated by gravimetric, linear polarization, electrochemical impedance spectroscopy and scanning electron microscopy techniques.


2018 ◽  
Vol 2018 ◽  
pp. 1-9 ◽  
Author(s):  
Liang Liu ◽  
Ting-Ting Cao ◽  
Qi-Wei Zhang ◽  
Chong-Wei Cui

Circulating cooling water plays an important role in industrial water use. In this study, the corrosion inhibition effects of PBTCA, HEDP, and ATMP organic phosphorus inhibitors were investigated using the weight loss method by varying the dosage of inhibitors, ClO2 concentrations, and pH values on carbon steel in recirculating cooling water with a low concentration of ClO2 solution. The results showed that the three corrosion inhibitors had a satisfactory corrosion inhibition effect and that corrosion inhibition efficiency is positively correlated with the concentration of organic phosphorus inhibitors and pH. The average corrosion inhibition efficiency of the three inhibitors was about 80% at the concentration of inhibitors = 35 mg/L, pH = 9.0, and the concentration of ClO2 = 7.0 mg/L, of which the single-phosphorus molecular corrosion inhibitor proved to be the best inhibitor. When the ClO2 concentration was 7 mg/L, the corrosion inhibition efficiencies of the three corrosion inhibitors were relatively stable. Using the density functional theory (DFT) algorithm in the Gaussian 09 program, the optimization calculation was completed by the B3LYP/6-31G (d, p) method at the microlevel. The molecular structures of the three organic phosphorus inhibitors and the number of phosphorus-containing atoms were compared to the sustained-release properties. Organic phosphorus inhibitors, as an electronic buffer, not only provided electrons but also received electrons. They formed a complex with iron and zinc ions in water in order to attach to the surface of the carbon steel and to alleviate corrosion. In addition, the adsorption with a metal surface followed the Langmuir adsorption isotherm.


Sign in / Sign up

Export Citation Format

Share Document