Evaluation of a ground source geothermal heat pump to save energy and reduce CO 2 and noxious gas emissions in a pig house

2016 ◽  
Vol 111 ◽  
pp. 446-454 ◽  
Author(s):  
Md. Manirul Islam ◽  
Hong-Seok Mun ◽  
A. B. M. Rubayet Bostami ◽  
Sonia Tabasum Ahmed ◽  
Keum-Joo Park ◽  
...  
2020 ◽  
Vol 5 ◽  
pp. 11
Author(s):  
Sabrin Korichi ◽  
Bachir Bouchekima ◽  
Nabiha Naili ◽  
Messaouda Azzouzi

Motivated by the rapid spread of the novel pandemic disease (COVID-19) that swept the most countries in the world, a new radiation heating system consists of wall radiator panel system connected to a reversible geothermal heat pump (GHP) coupled with horizontal ground heat exchanger (HGHX) was proposed as fast and permanent solution to the risks of the dispersion of airborne infectious diseases in air-conditioned enclosed spaces. An experimental system was installed and tested in the laboratory of thermal process of Research and Technology Center of Energy (CRTEn), Tunisia, in order to achieve the two main goals of this work: developing a new radiation heating system with quick and inexpensive implementation while ensuring high efficiency and environment-friendly performance for the entire system. The results obtained show that it is feasible to use the novel RPHs as heat rejecter of the horizontal ground source heat pump system (HGSHPs) for heating buildings with limited surface land areas epically those located in the Mediterranean regions such as Tunisia, the average performance coefficients of the geothermal heat pump COPhp and the overall system COPsys are found to be 6.3 and 3, respectively. The thermal comfort analysis indicates that there is only a small vertical temperature fluctuation in the test room that would not produce any negative effect on thermal comfort.


2011 ◽  
Vol 347-353 ◽  
pp. 1801-1805
Author(s):  
Arif Hepbasli ◽  
Mustafa Tolga Balta ◽  
Zeyad Alsuhaibani

In this study, we considered a building, which had a volume of 336 m3 and a floor area of 120 m2, with indoor and outdoor air temperatures of 20 oC and 0 oC, respectively. For heating this building, we selected two options, namely (i) a ground-source (geothermal) heat pump system (Case 1), and (ii) a solar collector heating system (Case 2). We employed both energy and exergy analysis methods to assess their performances and compare them through energy and exergy efficiencies and sustainability index. We also investigated energy and exergy flows for this building and illustrated from the primary energy transformation through the heat production system and a distribution system to a heating system, and from there, via the indoor air, across the building envelope to the surrounding air. We calculated that the total exergy efficiencies for Cases 1 and 2 were 4.7%, and 26.1% while sustainability index values for both cases were 1.049 and 1.353 at a reference (dead) state temperature of 0 oC, respectively.


2013 ◽  
Vol 2013 ◽  
pp. 1-6 ◽  
Author(s):  
Silvia Cocchi ◽  
Sonia Castellucci ◽  
Andrea Tucci

The need to address climate change caused by greenhouse gas emissions attaches great importance to research aimed at using renewable energy. Geothermal energy is an interesting alternative concerning the production of energy for air conditioning of buildings (heating and cooling), through the use of geothermal heat pumps. In this work a model has been developed in order to simulate an air conditioning system with geothermal heat pump. A ground source heat pump (GSHP) uses the shallow ground as a source of heat, thus taking advantage of its seasonally moderate temperatures. GSHP must be coupled with geothermal exchangers. The model leads to design optimization of geothermal heat exchangers and to verify the operation of the geothermal plant.


Animals ◽  
2020 ◽  
Vol 10 (11) ◽  
pp. 2075
Author(s):  
Hong Seok Mun ◽  
Muhammad Ammar Dilawar ◽  
Myeong Gil Jeong ◽  
Dhanushka Rathnayake ◽  
Jun Sung Won ◽  
...  

This study examined the effects of a heating system using a ground source geothermal heat pump (GHP). A GHP was installed in a pig house, and a comparative analysis was performed between the GHP and the control (conventional heating system) in terms of the production performance, housing environment, noxious gas emissions, electricity consumption, and economics. The geothermal system performance index, such as the coefficient of performance (COP), inlet, and outlet temperature, were also evaluated. The outflow temperature during each period (weaning, growing, and finishing) was significantly higher than the inflow temperature in all three components of the GHP system. Similarly, the average internal temperature of the GHP-connected pig house was increased (p < 0.05) during each period. The carbon dioxide (CO2) concentration, electricity usage, and cost of electricity during the 16-week experimental period were reduced significantly in the GHP system relative to the control. The concentrations of ammonia (NH3) during the growing and finishing period and the concentrations of formaldehyde during the weaning phase were also lower in the GHP-installed pig house (p < 0.05). These results indicate that the GHP system can be used as an environmentally friendly renewable energy source in pig houses for sustainable pig production without harming the growth performance.


2017 ◽  
Vol 6 (2) ◽  
pp. 145 ◽  
Author(s):  
Clément Rousseau ◽  
Jean-Louis Comlan Fannou ◽  
Louis Lamarche ◽  
Stanislaw Kajl

Geothermal heat pump technology is currently one of the most interesting technologies used to heat buildings. There are two designs used in the industry: geothermal heat pump using a secondary ground loop and Direct Expansion (DX) ground source heat pump. The latter is less used, possibly because less research has been carried out for the design of this kind of heat pump. In this paper, a transient model using the Comsol Multiphysic of a DX ground heat pump is presented in heating mode with R22, and a comparison with experimental results is presented with a 24-hour test. It is shown that the model was adequately validated by our experiment with only a maximum difference of 15%. Following this validation, a parametric analysis was realised on the geometry of the borehole. This study concluded that to have the best heat extraction of the ground, the pipes shank spacing need to be important without increasing the borehole diameter.Keywords: Direct Expansion geothermal heat pump, Modeling, R22Article History: Received January 16th 2017; Received in revised form May 28th 2017; Accepted June 6th 2017; Available onlineHow to Cite This Article: Rousseau, C., Fannou, J.L.C., Lamarche, L. and Kajl, S. (2017) Modeling and Experimental Validation of a Transient Direct Expansion Heat Pump. International Journal of Renewable Energy Develeopment, 6(2), 145-155.https://doi.org/10.14710/ijred.6.2.145-155


Author(s):  
Abdeen Omer

Globally buildings are responsible for approximately 40% of the total world annual energy consumption. Most of this energy is for the provision of lighting, heating, cooling and air conditioning. An increase in awareness of the environmental impact of CO2, NOx and CFCs emissions triggered a renewed interest in environmentally friendly cooling and heating technologies. Under the 1997 Montreal Protocol, governments agreed to phase out chemicals used as refrigerants that have the potential to destroy stratospheric ozone. An approach isneeded to integrate renewable energies in a way to achieve high building performance standards. However, because renewable energy sources are stochastic and geographically diffuse, their ability to match demand is determined by the adoption of one of the following two approaches: the utilisation of a capture area greater than that occupied by the community to be supplied, or the reduction of the community’s energy demands to a level commensurate with the locally available renewable resources. Ground source heat pump (GSHP) systems (also referred to as geothermal heat pump systems, earth-energy systems and GeoExchange systems) have received considerable attention in recent decades as an alternative energy source for residential and commercial space heating and cooling applications. The GSHP applications are one of three categories of geothermal energy resources as defined by ASHRAE and include high-temperature (>150°C) for electric power production, intermediate temperature (<150°C) for direct-use applications and GSHP applications (generally (<32°C). The GSHP applications are distinguished from the others by the fact that they operate at relatively low temperatures.


Sign in / Sign up

Export Citation Format

Share Document