Thermal performance of a heating system combining solar air collector with hollow ventilated interior wall in residential buildings on Tibetan Plateau

Energy ◽  
2019 ◽  
Vol 182 ◽  
pp. 93-109 ◽  
Author(s):  
Tao Yu ◽  
Bowan Liu ◽  
Bo Lei ◽  
Yanping Yuan ◽  
Haiquan Bi ◽  
...  
2014 ◽  
Vol 13 (8) ◽  
pp. 1965-1970 ◽  
Author(s):  
Spiru Paraschiv ◽  
Lizica Simona Paraschiv ◽  
Ion V. Ion

2020 ◽  
Vol 13 (1) ◽  
pp. 201
Author(s):  
Pau Chung Leng ◽  
Gabriel Hoh Teck Ling ◽  
Mohd Hamdan Ahmad ◽  
Dilshan Remaz Ossen ◽  
Eeydzah Aminudin ◽  
...  

The provision requirement of 10% openings of the total floor area stated in the Uniform Building By-Law 1984 Malaysia is essential for natural lighting and ventilation purposes. However, focusing on natural ventilation, the effectiveness of thermal performance in landed residential buildings has never been empirically measured and proven, as most of the research emphasized simulation modeling lacking sufficient empirical validation. Therefore, this paper drawing on field measurement investigates natural ventilation performance in terraced housing with an air-well system. The key concern as to what extent the current air-well system serving as a ventilator is effective to provide better thermal performance is to be addressed. By adopting an existing single-story air-welled terrace house, indoor environmental conditions and thermal performance were monitored and measured using HOBO U12 air temperature and humidity, the HOBO U12 anemometer, and the Delta Ohm HD32.3 Wet Bulb Globe Temperature meter for a six-month duration. The results show that the air temperature of the air well ranged from 27.48 °C to 30.92 °C, with a mean relative humidity of 72.67% to 79.25%. The mean air temperature for a test room (single-sided ventilation room) ranged from 28.04 °C to 30.92 °C, with a relative humidity of 70.16% to 76.00%. These empirical findings are of importance, offering novel policy insights and suggestions. Since the minimum provision of 10% openings has been revealed to be less effective to provide desirable thermal performance and comfort, mandatory compliance with and the necessity of the bylaw requirement should be revisited.


2011 ◽  
Vol 71-78 ◽  
pp. 2073-2076
Author(s):  
Fen E Hu ◽  
Zhi Juan Wang

A solar air drying system including solar air collector, drying cabinet and air blower for notoginseng drying has been constructed and tested. Two identical air solar collectors with two air channels, V-groove absorption heat plates and a single glass cover have been employed. The results of test show that the solar air collectors can obtain a good thermal performance in winter season. When the air flow mass rate is fixed at 0.0597kg·s-1, the maximum values of thermal efficiency and outlet air temperature are 76.0% and 62.2°C, respectively. The experimental analysis between two sampling notoginseng drying suggests that the solar drying is very effective, and the drying time has been shorten to about 440 minutes from 990 minutes of the traditional drying by sun. It is also observed that using the solar drying system notoginseng has a higher quality than traditional drying method.


2013 ◽  
Vol 482 ◽  
pp. 81-84
Author(s):  
Ke Wei Ding ◽  
Wu Sun ◽  
Dong Chen

This paper introduces a new type of rock wool color steel sandwich which is produced by Anhui sambo steel co.,Ltd. The thermal performance analysis of this kind of sandwich is conducted through the finite element software ANSYS in this paper, which reveal the widespread existence of cold bridge phenomenon. And this paper also propose several new ideas on how to reduce the cold bridge condensation of interior wall panels of building.


2014 ◽  
Vol 10 (1) ◽  
pp. 172-183 ◽  
Author(s):  
Sushil B. Bajracharya

This paper seeks to investigate into the aspects of thermal performance of traditional residential buildings in traditional settlements of Kathmandu valley. This study proceeds to analyze the detailed field data collected, with a view to identify the indoor thermal environment with respect to outdoor thermal environment in different seasons. This paper also compares the thermal performance of traditional buildings with modern residential buildings of traditional settlements of the valley. There is a regression analysis to obtain information about the thermal environment of different traditional and modern residential buildings with different conditions. The paper concludes that, thermal performance of traditional residential building, adapted in various ways to the changing thermal regime for thermal comfort is better than that of contemporary buildings.DOI: http://dx.doi.org/10.3126/jie.v10i1.10898Journal of the Institute of Engineering, Vol. 10, No. 1, 2014,  pp. 172–183


Sign in / Sign up

Export Citation Format

Share Document