Mechanical instability of a solid inclusion in a soft matrix due to indentation

Author(s):  
Shengchen Liu ◽  
Kai-tak Wan
2020 ◽  
Vol 67 (1) ◽  
pp. 111-115
Author(s):  
Sergey A. Voynash ◽  
Viktoriya A. Sokolova ◽  
Viktor I. Kretinin ◽  
Viktor A. Markov ◽  
Elena A. Alekseeva Alekseeva ◽  
...  

One of the main factors that determine the resistance of blade working bodies against damage under dynamic loads is their resistance to plastic crumpling, brittle or fatigue failure. Hard alloys that strengthen the blades of tillage parts are more brittle materials than steel, so the blunting of their edges is caused by the formation of cracks, their gradual growth or microchipping, even from a possible single impact of a solid inclusion in the soil. In addition to the usual brittle fracture of hard alloys, fatigue failure occurs under cyclic impact conditions. (Research purpose) The research purpose is in identifying the pattern of destruction of the blade edge of soil-cutting parts of forestry machines and theoretically justifying the algorithm for assessing the strength to determine the rational thickness of the wear-resistant coating during hardening. (Materials and methods) The article presents the main regularities of the influence of material properties and geometric parameters of the blade on the radius of rounding. (Results and discussion) The process of breaking the edge of the blade of hardened working bodies of forestry machines has been studied. The claim that the blunting of the blades is mainly due to its destruction and not to wear has been proved. The article presents a method for evaluating the strength of bimetallic blades of soil-cutting parts of forestry machines. It was found that the blunting of the blade occurs as a result of edge destruction in the process of multiple impacts of solid soil inclusions along the edge of the blade. (Conclusions) The article shows that the destruction of the edge of the blade leads to blunting of soil-cutting parts, which affects their performance. It was found that the sharpness of a self-sharpening hardened blade is determined by the thickness of the reinforcing layer and its ability to resist destruction under impact.


2020 ◽  
Vol 10 (8) ◽  
pp. 2790
Author(s):  
Wenzheng Zhuang ◽  
Chao Yang ◽  
Zhigang Wu

Hybrid corrugated sandwich (HCS) plates have become a promising candidate for novel thermal protection systems (TPS) due to their multi-functionality of load bearing and thermal protection. For hypersonic vehicles, the novel TPS that performs some structural functions is a potential method of saving weight, which is significant in reducing expensive design/manufacture cost. Considering the novel TPS exposed to severe thermal and aerodynamic environments, the mechanical stability of the HCS plates under fluid-structure-thermal coupling is crucial for preliminary design of the TPS. In this paper, an innovative layerwise finite element model of the HCS plates is presented, and coupled fluid-structure-thermal analysis is performed with a parameter study. The proposed method is validated to be accurate and efficient against commercial software simulation. Results have shown that the mechanical instability of the HCS plates can be induced by fluid-structure coupling and further accelerated by thermal effect. The influences of geometric parameters on thermal buckling and dynamic stability present opposite tendencies, indicating a tradeoff is required for the TPS design. The present analytical model and numerical results provide design guidance in the practical application of the novel TPS.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Markus Wenning ◽  
Dominic Gehring ◽  
Thomas Lange ◽  
David Fuerst-Meroth ◽  
Paul Streicher ◽  
...  

Abstract Background Chronic ankle instability (CAI) arises from the two etiological factors of functional (FAI) and mechanical ankle instability (MAI). To distinguish the contributions of the two etiologies, it is necessary to quantitively assess functional and mechanical deficits. Validated and reproducible assessment of mechanical instability remains a challenge in current research and practice. Physical examination, stress sonography and a novel 3D stress MRI have been used, while stress radiography has been called into question and arthrometry is limited to research purposes. The interaction of these primarily mechanical measurements with the functional and subjective components of CAI are subject to debate. The aim of this study was the evaluation of the clinical and biomechanical preferences of the three different methods in the diagnosis of MAI. Methods In this cross-sectional diagnostic study, we compared three different diagnostic approaches to mechanical ankle instability: (1) manual stress testing (anterior drawer test [ADT] and talar tilt test [TTT]), (2) stress sonography and (3) 3D stress MRI (3SAM) The latter includes quantification of 3D cartilage contact area (CCA) in plantarflexion-supination compared to neutral-null position. We applied these measurements to a cohort of patients suffering from chronic mechanical ankle instability (n = 25) to a matched cohort of healthy controls (n = 25). Perceived instability was assessed using the Cumberland Ankle Instability Tool (CAIT) and Forgotten Joint Score (FJS). Functional deficits were measured using postural sway and the y-Balance test. Results Significant differences between the two groups (single-factor “group” ANOVA, p < 0.05) were found in all of the mechanical assessments with strong effect sizes. Spearman’s correlations were strong for CAIT and manual stress testing (TTT rho = − 0.83, ADT rho = − 0.81), 3D stress MRI (rho = − 0.53) and stress sonography (TTT rho = − 0.48, ADT rho = − 0.44). Furthermore, the correlation between manual stress testing and CCA in the fibulotalar articulation (CCAFT) was strong (rho = 0.54) and the correlations to stress sonography were moderate (ADT rho = 0.47 and TTT rho = 0.43). The calculation of cutoff values revealed a distance of > 5.4 mm increase in ligament length during stress sonography (sensitivity 0.92, specificity 0.6) and > 43% loss of articulating surface in the fibulotalar joint (CCAFT in supination-plantarflexion using 3SAM, sensitivity 0.71, specificity 0.8) as potential cutoff values for diagnosing MAI. Conclusions Manual stress testing showed to be a valuable method of identifying mechanical ankle instability. However, due to is subjective character it may overvalue patient-reported instability as a factor which explains the high correlation to the CAIT-score, but this may also reduce its value in diagnosing the isolated mechanical quality of the joint. Thus, there is a persisting need for objective and reproducible alternatives focusing on MAI. According to our results, 3D stress MRI and stress sonography represent valuable alternatives and may be used to quantitively assess mechanical ankle instability in research and practice. Trial registration German Registry of Clinical Trials # DRKS00016356, registered on 05/11/2019.


2020 ◽  
Vol 7 (Supplement_1) ◽  
pp. i45-i53
Author(s):  
Rupesh Kotecha ◽  
Nicolas Dea ◽  
Jay S Detsky ◽  
Arjun Sahgal

Abstract With the growing incidence of new cases and the increasing prevalence of patients living longer with spine metastasis, a methodological approach to the management of patients with recurrent or progressive disease is increasing in relevance and importance in clinical practice. As a result, disease management has evolved in these patients using advanced surgical and radiotherapy technologies. Five key goals in the management of patients with spine metastases include providing pain relief, controlling metastatic disease at the treated site, improving neurologic deficits, maintaining or improving functional status, and minimizing further mechanical instability. The focus of this review is on advanced reirradiation techniques, given that the majority of patients will be treated with upfront conventional radiotherapy and further treatment on progression is often limited by the cumulative tolerance of nearby organs at risk. This review will also discuss novel surgical approaches such as separation surgery, minimally invasive percutaneous instrumentation, and laser interstitial thermal therapy, which is increasingly being coupled with spine reirradiation to maximize outcomes in this patient population. Lastly, given the complexities of managing recurrent spinal disease, this review emphasizes the importance of multidisciplinary care from neurosurgery, radiation oncology, medical oncology, neuro-oncology, rehabilitation medicine, and palliative care.


2021 ◽  
Vol 29 (1) ◽  
pp. 230949902098457
Author(s):  
Chengjie Yuan ◽  
Genrui Zhu ◽  
Zhifeng Wang ◽  
Chen Wang ◽  
Xu Wang ◽  
...  

Purpose: This study aimed to use MRI to evaluate the fibula and talus position difference in functional and mechanical ankle stability patients. Methods: 61 and 68 patients with functional and mechanical instability, and 60 healthy volunteers were involved. Based on the axial MRI images, the rotation of the talus was identified through the Malleolar Talus Index (MTI). The position relative to the talus (Axial Malleolar Index, AMI) and medial malleolus (Intermalleolar Index, IMI) were used to evaluated the displacement of the fibula. Results: Post hoc analysis showed that the values of malleolar talus index was significantly larger among mechanical instability (89.18° ± 2.31°) than that in functional instability patients (86.55° ±61.65°, P < 0.001) and healthy volunteers (85.59° ± 2.42°, P < 0.001). The axial malleolar index of the mechanical instability patients (11.39° ± 1.41°) were significantly larger than healthy volunteers (7.91° ± 0.83°) (P < 0.0001). There were no statistically significant differences in the above three indexes between the functional instability patients and healthy volunteers. Conclusion: The functional instability patients didn’t have a posteriorly positioned fibula and an internally rotated talus. The malleolar talus index was significantly larger among mechanical instability patients than that in functional instability patients. Increased malleolar talus index may become a new indirect MRI sign for identifying functional and mechanical instability patients.


Author(s):  
Arjun Krishnan ◽  
Ashwin Krishnan ◽  
Mark Costello

This article examines the fundamental aspects of controlling ground resonance in rotorcraft equipped with actively controlled landing gear. Ground resonance is a mechanical instability affecting rotorcraft on the ground. It occurs at certain rotor speeds, where the lead–lag motion of the rotor couples with the motion of fuselage creating a self-excited oscillation. Typically, passive or semi-active lag dampers are used to avoid instability; however, these are undesirable from a design and maintenance perspective. Innovations in active landing gear for rotorcraft, such as articulated robotic legs, have provided an alternate approach to avoid the instability, eliminating the need for lag dampers with respect to ground resonance. This article extends classic ground resonance to include movable landing gear and identifies key physical parameters affecting dynamic behavior. Applying LQ optimal control to this model, it is shown that ground resonance instability can be eliminated using active landing gear as the control mechanism, even when there is no lag damping present in the rotor. In addition, while superior performance is achieved when landing gear movement can occur both longitudinally and laterally, it is still possible to stabilize ground resonance with inputs in a single direction, albeit with reduced performance.


2014 ◽  
Vol 112 (9) ◽  
Author(s):  
Sung Hoon Kang ◽  
Sicong Shan ◽  
Andrej Košmrlj ◽  
Wim L. Noorduin ◽  
Samuel Shian ◽  
...  

2017 ◽  
Vol 17 (1) ◽  
pp. 143-146 ◽  
Author(s):  
S. Sobula ◽  
E. Olejnik ◽  
T. Tokarski

Abstract Wear resistance of TiC-cast steel metal matrix composite has been investigated. Composites were obtained with SHSB method known as SHS synthesis during casting. It has been shown the differences in wear between composite and base cast steel. The Miller slurry machine test were used to determine wear loss of the specimens. The slurry was composed of SiC and water. The worn surface of specimens after test, were studied by SEM. Experimental observation has shown that surface of composite zone is not homogenous and consist the matrix lakes. Microscopic observations revealed the long grooves with SiC particles indented in the base alloy area, and spalling pits in the composite area. Due to the presence of TiC carbides on composite layer, specimens with TiC reinforced cast steel exhibited higher abrasion resistance. The wear of TiC reinforced cast steel mechanism was initially by wearing of soft matrix and in second stage by polishing and spalling of TiC. Summary weight loss after 16hr test was 0,14÷0,23 g for composite specimens and 0,90 g for base steel.


Sign in / Sign up

Export Citation Format

Share Document