scholarly journals On Expressive Features for Gait Analysis using Lower Limb Inertial Sensor Data

2020 ◽  
Vol 53 (2) ◽  
pp. 15990-15997
Author(s):  
Felix Laufer ◽  
Michael Lorenz ◽  
Bertram Taetz ◽  
Gabriele Bleser
Sensors ◽  
2021 ◽  
Vol 21 (22) ◽  
pp. 7517
Author(s):  
Vânia Guimarães ◽  
Inês Sousa ◽  
Miguel Velhote Correia

Gait performance is an important marker of motor and cognitive decline in older adults. An instrumented gait analysis resorting to inertial sensors allows the complete evaluation of spatiotemporal gait parameters, offering an alternative to laboratory-based assessments. To estimate gait parameters, foot trajectories are typically obtained by integrating acceleration two times. However, to deal with cumulative integration errors, additional error handling strategies are required. In this study, we propose an alternative approach based on a deep recurrent neural network to estimate heel and toe trajectories. We propose a coordinate frame transformation for stride trajectories that eliminates the dependency from previous strides and external inputs. Predicted trajectories are used to estimate an extensive set of spatiotemporal gait parameters. We evaluate the results in a dataset comprising foot-worn inertial sensor data acquired from a group of young adults, using an optical motion capture system as a reference. Heel and toe trajectories are predicted with low errors, in line with reference trajectories. A good agreement is also achieved between the reference and estimated gait parameters, in particular when turning strides are excluded from the analysis. The performance of the method is shown to be robust to imperfect sensor-foot alignment conditions.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Andrew P. Creagh ◽  
Florian Lipsmeier ◽  
Michael Lindemann ◽  
Maarten De Vos

AbstractThe emergence of digital technologies such as smartphones in healthcare applications have demonstrated the possibility of developing rich, continuous, and objective measures of multiple sclerosis (MS) disability that can be administered remotely and out-of-clinic. Deep Convolutional Neural Networks (DCNN) may capture a richer representation of healthy and MS-related ambulatory characteristics from the raw smartphone-based inertial sensor data than standard feature-based methodologies. To overcome the typical limitations associated with remotely generated health data, such as low subject numbers, sparsity, and heterogeneous data, a transfer learning (TL) model from similar large open-source datasets was proposed. Our TL framework leveraged the ambulatory information learned on human activity recognition (HAR) tasks collected from wearable smartphone sensor data. It was demonstrated that fine-tuning TL DCNN HAR models towards MS disease recognition tasks outperformed previous Support Vector Machine (SVM) feature-based methods, as well as DCNN models trained end-to-end, by upwards of 8–15%. A lack of transparency of “black-box” deep networks remains one of the largest stumbling blocks to the wider acceptance of deep learning for clinical applications. Ensuing work therefore aimed to visualise DCNN decisions attributed by relevance heatmaps using Layer-Wise Relevance Propagation (LRP). Through the LRP framework, the patterns captured from smartphone-based inertial sensor data that were reflective of those who are healthy versus people with MS (PwMS) could begin to be established and understood. Interpretations suggested that cadence-based measures, gait speed, and ambulation-related signal perturbations were distinct characteristics that distinguished MS disability from healthy participants. Robust and interpretable outcomes, generated from high-frequency out-of-clinic assessments, could greatly augment the current in-clinic assessment picture for PwMS, to inform better disease management techniques, and enable the development of better therapeutic interventions.


2021 ◽  
Vol 185 ◽  
pp. 282-291
Author(s):  
Nizam U. Ahamed ◽  
Kellen T. Krajewski ◽  
Camille C. Johnson ◽  
Adam J. Sterczala ◽  
Julie P. Greeves ◽  
...  

Sensors ◽  
2021 ◽  
Vol 21 (7) ◽  
pp. 2480
Author(s):  
Isidoro Ruiz-García ◽  
Ismael Navarro-Marchal ◽  
Javier Ocaña-Wilhelmi ◽  
Alberto J. Palma ◽  
Pablo J. Gómez-López ◽  
...  

In skiing it is important to know how the skier accelerates and inclines the skis during the turn to avoid injuries and improve technique. The purpose of this pilot study with three participants was to develop and evaluate a compact, wireless, and low-cost system for detecting the inclination and acceleration of skis in the field based on inertial measurement units (IMU). To that end, a commercial IMU board was placed on each ski behind the skier boot. With the use of an attitude and heading reference system algorithm included in the sensor board, the orientation and attitude data of the skis were obtained (roll, pitch, and yaw) by IMU sensor data fusion. Results demonstrate that the proposed IMU-based system can provide reliable low-drifted data up to 11 min of continuous usage in the worst case. Inertial angle data from the IMU-based system were compared with the data collected by a video-based 3D-kinematic reference system to evaluate its operation in terms of data correlation and system performance. Correlation coefficients between 0.889 (roll) and 0.991 (yaw) were obtained. Mean biases from −1.13° (roll) to 0.44° (yaw) and 95% limits of agreements from 2.87° (yaw) to 6.27° (roll) were calculated for the 1-min trials. Although low mean biases were achieved, some limitations arose in the system precision for pitch and roll estimations that could be due to the low sampling rate allowed by the sensor data fusion algorithm and the initial zeroing of the gyroscope.


2014 ◽  
Vol 79 ◽  
pp. 417-426 ◽  
Author(s):  
Hsien-Yung Huang ◽  
Jian-Shiang Chen ◽  
Chia-En Huang
Keyword(s):  

2011 ◽  
Vol 467-469 ◽  
pp. 108-113
Author(s):  
Xin Yu Li ◽  
Dong Yi Chen

Accurate tracking for Augmented Reality applications is a challenging task. Multi-sensors hybrid tracking generally provide more stable than the effect of the single visual tracking. This paper presents a new tightly-coupled hybrid tracking approach combining vision-based systems with inertial sensor. Based on multi-frequency sampling theory in the measurement data synchronization, a strong tracking filter (STF) is used to smooth sensor data and estimate position and orientation. Through adding time-varying fading factor to adaptively adjust the prediction error covariance of filter, this method improves the performance of tracking for fast moving targets. Experimental results show the efficiency and robustness of this proposed approach.


Author(s):  
Gunjan Patel ◽  
Rajani Mullerpatan ◽  
Bela Agarwal ◽  
Triveni Shetty ◽  
Rajdeep Ojha ◽  
...  

Wearable inertial sensor-based motion analysis systems are promising alternatives to standard camera-based motion capture systems for the measurement of gait parameters and joint kinematics. These wearable sensors, unlike camera-based gold standard systems, find usefulness in outdoor natural environment along with confined indoor laboratory-based environment due to miniature size and wireless data transmission. This study reports validation of our developed (i-Sens) wearable motion analysis system against standard motion capture system. Gait analysis was performed at self-selected speed on non-disabled volunteers in indoor ( n = 15) and outdoor ( n = 8) environments. Two i-Sens units were placed at the level of knee and hip along with passive markers (for indoor study only) for simultaneous 3D motion capture using a motion capture system. Mean absolute percentage error (MAPE) was computed for spatiotemporal parameters from the i-Sens system versus the motion capture system as a true reference. Mean and standard deviation of kinematic data for a gait cycle were plotted for both systems against normative data. Joint kinematics data were analyzed to compute the root mean squared error (RMSE) and Pearson’s correlation coefficient. Kinematic plots indicate a high degree of accuracy of the i-Sens system with the reference system. Excellent positive correlation was observed between the two systems in terms of hip and knee joint angles (Indoor: hip 3.98° ± 1.03°, knee 6.48° ± 1.91°, Outdoor: hip 3.94° ± 0.78°, knee 5.82° ± 0.99°) with low RMSE. Reliability characteristics (defined using standard statistical thresholds of MAPE) of stride length, cadence, walking speed in both outdoor and indoor environment were well within the “Good” category. The i-Sens system has emerged as a potentially cost-effective, valid, accurate, and reliable alternative to expensive, standard motion capture systems for gait analysis. Further clinical trials using the i-Sens system are warranted on participants across different age groups.


Sign in / Sign up

Export Citation Format

Share Document