The evolution of the ENERGY STAR® energy performance indicator for benchmarking industrial plant manufacturing energy use

2008 ◽  
Vol 16 (6) ◽  
pp. 709-715 ◽  
Author(s):  
Gale Boyd ◽  
Elizabeth Dutrow ◽  
Walt Tunnessen
Author(s):  
Mr. Kishan Khatri ◽  
Dr. Shweta Choudhary

The aim of research is to identify a need of a baseline energy use for benchmarking the minimum energy performance of the buildings for different climate zones of India. Its objective is to provide information and create awareness among customers on energy performance so that consumers can make informed decisions while purchasing appliances, selecting the ECMs and in creating a sustainable home. This study will help in the identification of underperforming buildings to target for efficiency improvements, identify best practices from efficient buildings, set investment priorities, verify savings and prevent snapback, share and report performance, earn recognition, continuous monitoring and implement a comprehensive management program. There are rating system available in India i.e. BEE Star Labelling program and GRIHA Baseline Energy Use to support these requirements. However, there are some limitation in the terms of Climate Zones and Standardization. The baseline energy use differs with each other on a certain parameter, which can create a misinterpretation for the building owners to rely on any standard. There is a need of knowing the current status/performance of the building as comparison to the similar type of buildings in India in respective climate zones. There is a further need to getting recognized by the authority at national level providing the status of the building energy performance. Enormous studies have been made and have suggested to follow the best Energy Conservation Measures (ECM’s) in the buildings. However, there is no portal or tool which can guide what further energy performance is needed to choose the ECMs accordingly. There is an online portal called Energy Star Portfolio Manager in USA which looks closer to the need and for the same a research has been carried out including all the stakeholders, engineers, architects, consultants to come up with the need of online benchmarking tool, accessible for all the building holders. Further, the expertise of BEE Certified Energy Auditors and Energy Managers can be helpful in the identification of this eco system of energy use benchmarking for the different climate zones of India. KEYWORDS: Energy Use; Green Buildings; Climate Zones; Energy Performance Benchmarking; Energy Star Portfolio Manager


Author(s):  
N. Fumo ◽  
P. J. Mago ◽  
L. M. Chamra

Cooling, Heating and Power (CHP) systems are a form of distributed generation that uses internal combustion prime-power engines to generate electricity while recovering heat for other uses. CHP is a promising technology for increasing energy efficiency through the use of distributed electric and thermal energy recovery-delivery systems at or near end-user sites. Although this technology seems to be economically feasible, the evaluation and comparison of CHP systems cannot be restricted to economical considerations only. Standard economic analysis, such as life cycle economic analysis, does not take in consideration all the benefits that can be obtained from this technology. For this reason, several aspects to perform a non-conventional evaluation of CHP systems have to be considered. Among the aspects to be included in a non-conventional evaluation are: power reliability, power quality, environmental quality, energy-efficient buildings, fuel source flexibility, brand and marketing benefits, protection from electric rate hikes, and benefits from promoting energy management practices. Some benefits of these non-economical evaluations can be transferred into an economic evaluation but others give intangible potential to the technology. This paper focus on a non-conventional evaluation based on energy-efficient buildings, which is associated to energy conservation and improvement of the building energy performance rating for government energy programs like Energy Star and Leadership in Energy and Environmental Design (LEED). Results show that the use of CHP systems could improve the Energy Star Rating in more than 50 points. The Energy Star Rating is significant on the LEED Rating as a building can score up to 10 points of the 23 available in the Energy & Atmosphere category on energy efficiency alone. As much as 8 points can be obtained in this category due to the Energy Star rating increment from the use of CHP systems. Clearly the use of CHP systems will help building owners to reach the benefits from these energy programs while improving the overall energy use and energy cost.


Energies ◽  
2020 ◽  
Vol 13 (14) ◽  
pp. 3570
Author(s):  
Endrik Arumägi ◽  
Targo Kalamees

The current study demonstrates the possibilities of reducing energy use and construction costs and provides evidence that wooden nearly-zero-energy buildings (nZEB) are technically possible at affordable construction costs by using novel design processes and procurement models that enable scalable and modular production. The energy efficiency solutions were derived by increasing/decreasing the insulation value of the building envelope in successive steps. Financial calculations were based on the investment needed to achieve the nearly-zero-energy levels. Overall, many opportunities exist to decrease the cost and energy use compared to the current (pre-nZEB) practice because the net present value can change up to 150 €/m² on the same energy performance indicator (EPI) level. The EPI in the cost-even range was reached by combining a ground-source heat pump (between 115 and 128 kWh/(m2·a)) and efficient district heating (between 106 and 124 kWh/(m2·a)). As energy efficiency decreases, improving energy efficiency becomes more expensive by insulation measures. Throughout the EPI range the most cost efficient was investment in the improvement of the thermal transmittance of windows (3–13 €/(kWh/(m2·a))) while investments in other building envelope parts were less effective (4–80 €/(kWh/(m2·a))). If these were possible to install, photovoltaic (PV) panels installed to the roof would be the cheapest solution to improve the energy performance. Integrated project delivery procurement (design and construction together) and the use of prefabricated wooden structures reduced the constructing cost by half (from ~2700 €/net m2 to 1390 €/net m2) and helped to keep the budget within limits.


Energies ◽  
2021 ◽  
Vol 14 (3) ◽  
pp. 749
Author(s):  
John H. Scofield ◽  
Susannah Brodnitz ◽  
Jakob Cornell ◽  
Tian Liang ◽  
Thomas Scofield

In this work, we present results from the largest study of measured, whole-building energy performance for commercial LEED-certified buildings, using 2016 energy use data that were obtained for 4417 commercial office buildings (114 million m2) from municipal energy benchmarking disclosures for 10 major U.S. cities. The properties included 551 buildings (31 million m2) that we identified as LEED-certified. Annual energy use and greenhouse gas (GHG) emission were compared between LEED and non-LEED offices on a city-by-city basis and in aggregate. In aggregate, LEED offices demonstrated 11% site energy savings but only 7% savings in source energy and GHG emission. LEED offices saved 26% in non-electric energy but demonstrated no significant savings in electric energy. LEED savings in GHG and source energy increased to 10% when compared with newer, non-LEED offices. We also compared the measured energy savings for individual buildings with their projected savings, as determined by LEED points awarded for energy optimization. This analysis uncovered minimal correlation, i.e., an R2 < 1% for New Construction (NC) and Core and Shell (CS), and 8% for Existing Euildings (EB). The total measured site energy savings for LEED-NC and LEED-CS was 11% lower than projected while the total measured source energy savings for LEED-EB was 81% lower than projected. Only LEED offices certified at the gold level demonstrated statistically significant savings in source energy and greenhouse gas emissions as compared with non-LEED offices.


2021 ◽  
Vol 13 (4) ◽  
pp. 1595
Author(s):  
Valeria Todeschi ◽  
Roberto Boghetti ◽  
Jérôme H. Kämpf ◽  
Guglielmina Mutani

Building energy-use models and tools can simulate and represent the distribution of energy consumption of buildings located in an urban area. The aim of these models is to simulate the energy performance of buildings at multiple temporal and spatial scales, taking into account both the building shape and the surrounding urban context. This paper investigates existing models by simulating the hourly space heating consumption of residential buildings in an urban environment. Existing bottom-up urban-energy models were applied to the city of Fribourg in order to evaluate the accuracy and flexibility of energy simulations. Two common energy-use models—a machine learning model and a GIS-based engineering model—were compared and evaluated against anonymized monitoring data. The study shows that the simulations were quite precise with an annual mean absolute percentage error of 12.8 and 19.3% for the machine learning and the GIS-based engineering model, respectively, on residential buildings built in different periods of construction. Moreover, a sensitivity analysis using the Morris method was carried out on the GIS-based engineering model in order to assess the impact of input variables on space heating consumption and to identify possible optimization opportunities of the existing model.


2021 ◽  
Vol 1 ◽  
pp. 3279-3288
Author(s):  
Maria Hein ◽  
Darren Anthony Jones ◽  
Claudia Margot Eckert

AbstractEnergy consumed in buildings is a main contributor to CO2 emissions, there is therefore a need to improve the energy performance of buildings, particularly commercial buildings whereby building service systems are often substantially over-designed due to the application of excess margins during the design process.The cooling system of an NHS Hospital was studied and modelled in order to identify if the system was overdesigned, and to quantify the oversizing impact on the system operational and embodied carbon footprints. Looking at the operational energy use and environmental performance of the current system as well as an alternative optimised system through appropriate modelling and calculation, the case study results indicate significant environmental impacts are caused by the oversizing of cooling system.The study also established that it is currently more difficult to obtain an estimate of the embodied carbon footprint of building service systems. It is therefore the responsibility of the machine builders to provide information and data relating to the embodied carbon of their products, which in the longer term, this is likely to become a standard industry requirement.


Sign in / Sign up

Export Citation Format

Share Document