Electrode placement in electrocardiography smart garments: A review

2019 ◽  
Vol 57 ◽  
pp. 27-30 ◽  
Author(s):  
Azadeh Soroudi ◽  
Niina Hernández ◽  
Lena Berglin ◽  
Vincent Nierstrasz
1989 ◽  
Vol 32 (4) ◽  
pp. 849-856 ◽  
Author(s):  
John P. Preece ◽  
Richard S. Tyler

Minimum-detectable gaps for sinusoidal stimuli were measured for three users of a multi electrode cochlear prosthesis as functions of stimulus level, frequency, and electrode place within the cochlea. Stimulus level was scaled by sensation level and by growth-of-loudness functions generated for each condition by direct magnitude estimation. Minimum-detectable gaps decreased with increase in either sensation level or loudness, up to a plateau. When compared at equal sensation levels, the minimum-detectable gaps decreased with frequency increases. The frequency effect on minimum-detectable gaps is reduced if the data are considered at equal loudness. Comparison across place of stimulation within the cochlea showed minimum-detectable gaps to be shorter for more basal electrode placement at low stimulus levels. No differences in minimum-detectable gap as a function of place were found at higher stimulus levels.


Author(s):  
Selma Büyükgöze

Brain Computer Interface consists of hardware and software that convert brain signals into action. It changes the nerves, muscles, and movements they produce with electro-physiological signs. The BCI cannot read the brain and decipher the thought in general. The BCI can only identify and classify specific patterns of activity in ongoing brain signals associated with specific tasks or events. EEG is the most commonly used non-invasive BCI method as it can be obtained easily compared to other methods. In this study; It will be given how EEG signals are obtained from the scalp, with which waves these frequencies are named and in which brain states these waves occur. 10-20 electrode placement plan for EEG to be placed on the scalp will be shown.


2019 ◽  
Vol 23 (3) ◽  
pp. 297-302 ◽  
Author(s):  
Julia D. Sharma ◽  
Kiran K. Seunarine ◽  
Muhammad Zubair Tahir ◽  
Martin M. Tisdall

OBJECTIVEThe aim of this study was to compare the accuracy of optical frameless neuronavigation (ON) and robot-assisted (RA) stereoelectroencephalography (SEEG) electrode placement in children, and to identify factors that might increase the risk of misplacement.METHODSThe authors undertook a retrospective review of all children who underwent SEEG at their institution. Twenty children were identified who underwent stereotactic placement of a total of 218 electrodes. Six procedures were performed using ON and 14 were placed using a robotic assistant. Placement error was calculated at cortical entry and at the target by calculating the Euclidean distance between the electrode and the planned cortical entry and target points. The Mann-Whitney U-test was used to compare the results for ON and RA placement accuracy. For each electrode placed using robotic assistance, extracranial soft-tissue thickness, bone thickness, and intracranial length were measured. Entry angle of electrode to bone was calculated using stereotactic coordinates. A stepwise linear regression model was used to test for variables that significantly influenced placement error.RESULTSBetween 8 and 17 electrodes (median 10 electrodes) were placed per patient. Median target point localization error was 4.5 mm (interquartile range [IQR] 2.8–6.1 mm) for ON and 1.07 mm (IQR 0.71–1.59) for RA placement. Median entry point localization error was 5.5 mm (IQR 4.0–6.4) for ON and 0.71 mm (IQR 0.47–1.03) for RA placement. The difference in accuracy between Stealth-guided (ON) and RA placement was highly significant for both cortical entry point and target (p < 0.0001 for both). Increased soft-tissue thickness and intracranial length reduced accuracy at the target. Increased soft-tissue thickness, bone thickness, and younger age reduced accuracy at entry. There were no complications.CONCLUSIONSRA stereotactic electrode placement is highly accurate and is significantly more accurate than ON. Larger safety margins away from vascular structures should be used when placing deep electrodes in young children and for trajectories that pass through thicker soft tissues such as the temporal region.


2019 ◽  
Vol 24 (3) ◽  
pp. 284-292
Author(s):  
Eisha A. Christian ◽  
Elysa Widjaja ◽  
Ayako Ochi ◽  
Hiroshi Otsubo ◽  
Stephanie Holowka ◽  
...  

OBJECTIVESmall lesions at the depth of the sulcus, such as with bottom-of-sulcus focal cortical dysplasia, are not visible from the surface of the brain and can therefore be technically challenging to resect. In this technical note, the authors describe their method of using depth electrodes as landmarks for the subsequent resection of these exacting lesions.METHODSA retrospective review was performed on pediatric patients who had undergone invasive electroencephalography with depth electrodes that were subsequently used as guides for resection in the period between July 2015 and June 2017.RESULTSTen patients (3–15 years old) met the criteria for this study. At the same time as invasive subdural grid and/or strip insertion, between 2 and 4 depth electrodes were placed using a hand-held frameless neuronavigation technique. Of the total 28 depth electrodes inserted, all were found within the targeted locations on postoperative imaging. There was 1 patient in whom an asymptomatic subarachnoid hemorrhage was demonstrated on postprocedural imaging. Depth electrodes aided in target identification in all 10 cases.CONCLUSIONSDepth electrodes placed at the time of invasive intracranial electrode implantation can be used to help localize, target, and resect primary zones of epileptogenesis caused by bottom-of-sulcus lesions.


Author(s):  
Beomcho Jun ◽  
Sunwha Song

Abstract Objective This paper describes the construction of portals for electrode placement during cochlear implantation and emphasises the utility of pre-operative temporal bone three-dimensional computed tomography. Methods Temporal bone three-dimensional computed tomography was used to plan portal creation for electrode insertion. Results Pre-operative temporal bone three-dimensional computed tomography can be used to determine the orientation of temporal bone structures, which is important for mastoidectomy, posterior tympanotomy and cochleostomy, and when using the round window approach. Conclusion It is essential to create appropriate portals (from the mastoid cortex to the cochlea) in a step-by-step manner, to ensure the safe insertion of electrodes into the scala tympani. Pre-operative three-dimensional temporal bone computed tomography is invaluable in this respect.


2020 ◽  
pp. 1-13
Author(s):  
Sendhil Govender ◽  
Sally M. Rosengren

BACKGROUND: The cervical vestibular evoked myogenic potential (cVEMP) can be affected by the recording parameters used to quantify the response. OBJECTIVE: We investigated the effects of electrode placement and montage on the variability and symmetry of sternocleidomastoid (SCM) contraction strength and cVEMP amplitude. METHODS: We used inter-side asymmetries in electrode placement to mimic small clinical errors in twenty normal subjects. cVEMPs were recorded at three active electrode sites and referred to the distal SCM tendon (referential montages: upper, conventional and lower). Additional bipolar montages were constructed offline to measure SCM contraction strength using closely-spaced electrode pairs (bipolar montages: superior, lower and outer). RESULTS: The conventional montage generally produced the largest cVEMP amplitudes (P <  0.001). SCM contraction strength was larger for referential montages than bipolar ones (P <  0.001). Inter-side electrode position errors produced large variations in cVEMP and SCM contraction strength asymmetries in some subjects, producing erroneous abnormal test results. CONCLUSION: Recording locations affect cVEMP amplitude and SCM contraction strength. In most cases, small changes in electrode position had only minor effects but, in a minority of subjects, the different montages produced large changes in cVEMP and contraction amplitudes and asymmetry, potentially affecting test outcomes.


Sensors ◽  
2021 ◽  
Vol 21 (8) ◽  
pp. 2804
Author(s):  
Silvia Imbesi ◽  
Sofia Scataglini

Smart clothing plays a big role to foster innovation and to. boost health and well-being, improving the quality of the life of people, especially when addressed to niche users with particular needs related to their health. Designing smart apparel, in order to monitor physical and physiological functions in older users, is a crucial asset that user centered design is exploring, balancing needs expressed by the users with technological requirements related to the design process. In this paper, the authors describe a user centered methodology for the design of smart garments based on the evaluation of users’ acceptance of smart clothing. This comparison method can be considered as similar to a simplified version of the quality function deployment tool, and is used to evaluate the general response of each garment typology to different categories of requirements, determining the propensity of the older user to the utilization of the developed product. The suggested methodology aims at introducing in the design process a tool to evaluate and compare developed solutions, reducing complexity in design processes by providing a tool for the comparison of significant solutions, correlating quantitative and qualitative factors.


Author(s):  
Matt D. Schalles ◽  
Dorian S. Houser ◽  
James J. Finneran ◽  
Peter Tyack ◽  
Barbara Shinn-Cunningham ◽  
...  

AbstractAuditory neuroscience in dolphins has largely focused on auditory brainstem responses; however, such measures reveal little about the cognitive processes dolphins employ during echolocation and acoustic communication. The few previous studies of mid- and long-latency auditory-evoked potentials (AEPs) in dolphins report different latencies, polarities, and magnitudes. These inconsistencies may be due to any number of differences in methodology, but these studies do not make it clear which methodological differences may account for the disparities. The present study evaluates how electrode placement and pre-processing methods affect mid- and long-latency AEPs in (Tursiops truncatus). AEPs were measured when reference electrodes were placed on the skin surface over the forehead, the external auditory meatus, or the dorsal surface anterior to the dorsal fin. Data were pre-processed with or without a digital 50-Hz low-pass filter, and the use of independent component analysis to isolate signal components related to neural processes from other signals. Results suggest that a meatus reference electrode provides the highest quality AEP signals for analyses in sensor space, whereas a dorsal reference yielded nominal improvements in component space. These results provide guidance for measuring cortical AEPs in dolphins, supporting future studies of their cognitive auditory processing.


Sign in / Sign up

Export Citation Format

Share Document